CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

HIOKI DC High Voltage Probe P2010

For Safe Inspection of High-voltage Solar PV Systems

The voltage of the solar installations (also known as photovoltaic or PV installations) increases to reduce cost and improve the efficiency of solar equipment. As a result, it is important to select measuring instruments that support higher voltage measurement to protect the safety of inspection workers. The P2010 enables high voltage measurement up to CAT III 2000 V by simply connecting to a compatible Hioki clamp meter or digital multimeter (DMM).

DC High Voltage Probe

Model:

P2010

Maker:

HIOKI E.E. CORPORATION

Feature

  • Enables high voltage measurement up to CAT Ⅲ 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid
  • Connects to compatible Hioki clamp meters & digital multimeters (DMMs)

Specifications

Accuracy guaranteed for 1 year

Maximum input voltage*1 2000 V DC
Maximum rated line-to-ground voltage 1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V
Input resistance 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
Overload protection 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L)
OUTPUT terminal 4 mm banana terminal
Operating temperature and humidity range Temperature:
-25°C to 65°C (-13°F to 149°F)

Humidity:
−25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing)

Storage temperature and humidity range -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
Standards EN 61010
Included accessories Instruction Manual ×1, Operating Precautions ×1

Accuracy table for compatible instruments

Model Combined accuracy
DT4261 Range 600.0 V: Combined accuracy ±0.8% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.8% rdg ±5 V
CM4141-50
CM4371-50
CM4373-50
CM4375-50
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V
DT4281
DT4282
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10)
DT4252
DT4253
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10)
DT4255
DT4256
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)

*1 Maximum rated voltage between INPUT H and INPUT L

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.