HIOKI AC/DC High Voltage Divider VT1005

Safely Measure High Voltages up to 5000 V, Detect Efficiency Improvement Effects on the Order of 0.1%

Inverters used in rail and power system applications convert high-voltage power. To measure the efficiency of such conversions, it’s necessary to measure voltages of 1000 V and above. The VT1005 divides voltages of up to 5000 V and outputs them to a power analyzer.In order to measure the efficiency of high-efficiency inverters with a high degree of precision, you need to be able to accurately measure power from DC to high frequencies. Thanks to its excellent frequency flatness, the VT1005 makes possible accurate measurement at frequencies ranging from the fundamental wave to switching-frequency components.

AC/DC High Voltage Divider

Model:

VT1005

Maker:

HIOKI E.E. CORPORATION

Features

  • Max. Input 5000 V (*1) – 2000 V CAT II / 1500 V CAT III
  • Measurement Accuracy: ±0.08% (DC) / ±0.04% (50/60 Hz) / ±0.17% (50 kHz)
  • Frequency Flatness: ±0.1% Amplitude Band 200 kHz Typ. / ±0.1° Phase Band 500 kHz Typ. (*2)
  • Measurement Band: DC to 4 MHz (-3 dB)
  • Noise Resistance: CMRR 80 dB Typ. (100 kHz) / Differential Input Method

*1:±7100 V peak, no measurement category, anticipated transient overvoltage of 0 V *2:After phase correction by the power analyzer

Videos

Specifications

Accuracy guaranteed for 1 year

Maximum rated voltage 5000 V rms, ±7100 V peak*1
Maximum rated voltage
(line-to-ground)
No measurement category: 5000 V AC/DC*2
Measurement category II: 2000 V AC/DC*3
Measurement category III: 1500 V AC/DC*4
Voltage dividing ratio 1000:1
Measurement accuracy ±0.08%(DC), ±0.04%(50/60 Hz), ±0.17% (50 kHz)
Frequency
flatness
Band where amplitude falls within ±0.1% range: 200 kHz (typical)
Band where phase falls within ±0.1° range: 500 kHz (typical)*5
Measurement bandwidth DC to 4 MHz (Amplitude and phase accuracy specified up to 1 MHz)
Common-mode voltage
rejection ratio (CMRR)
50 Hz/60 Hz: 90 dB(Typical)
100 kHz: 80 dB (Typical)
Measurement method Differential input
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Storage temperature and humidity range −20°C to 60°C (-4°F to 140°F), 80% RH or less (non-condensing)
Standards Safety: EN 61010
EMC: EN 61326 Class A
Power supply 100 V to 240 V AC (50/60 Hz)
Dimensions and Weight Approx. 195.0 mm (7.68 in) W × 83.2 mm (3.28 in) H × 346.0 mm (13.62 in) D mm
Approx. 2.2 kg (77.6 oz.)
Included accessories – L1050-01 Voltage Cord ×1 (1.6 m/ 5.25 ft)
– L9217 Connection Cord ×1 (insulated BNC, 1.6 m/ 5.25 ft)
– 9704 Conversion Adapter ×1 (insulated-female BNC-to-banana plug)
– Power cord ×1

*1 Within the frequency derating range
No measurement category: Applicable to the measurement of circuits that are not directly connected to the main power supply.
EXAMPLE: Measurement on the secondary-side equipment from the socket outlet of fixed installation through a transformer, etc.
*2:±7100 V peak, Anticipated transient overvoltage 0 V
*3:Anticipated transient overvoltage 12000 V
*4:Anticipated transient overvoltage 10000 V
*5:After phase correction by the power analyzer