CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

(discontinued) CONTEC Reed Relay Contact Output F&eIT I/O Module 4ch (Isolated – 125VAC – 30VDC) RRY-4(FIT)GY

Reed relay contact output F&eIT I/O module 4ch (isolated - 125VAC - 30VDC)

This product is the module for expansion (device module) which expands a reed relay junction output interface for various controllers. It is used connecting for I/O controller module CPU-CAxx(FIT)GY of F&eIT series, and microcontroller unit CPU-SBxx(FIT)GY. The relay output of a maximum of four points can be performed by one module.

Reed Relay Contact Output F&eIT I/O Module 4ch (Isolated - 125VAC - 30VDC)

Model:

RRY-4(FIT)GY

Maker:

CONTEC Co., Ltd.

Features

  • The independent common reed relay junction output of four points can be performed.
  • Output rating is designed by the large scale of a maximum of 125VAC/30VDC and 2A per point.
  • Device ID can be set up with a rotary switch and apparatus number management can be performed easily.
  • This module is equipped with 35mmDIN rail attachment mechanism as standard like other F&eIT series products. Moreover, the connection with a controller module can constitute a system simply and smartly without using connection apparatus, such as a backplane board, since it has unique composition which carries out a stack connection on the side.

Specifications

Add-on Module

Series F&eIT
Bus Specification F&eIT stack bus
Size F&eIT 1U
Used Connector –

Digital I/O

Input Channels –
Output Channels 4-ch
Bi-directional I/O Channels –
Response Time (Input) –
Response Time (Output) 7msec (max.)
Operating Voltage (Input) –
Operating Voltage (Output) to 125VAC / to 30VDC
Input Circuit –
Output Circuit Reed relay contact output
Built-in Power Supply –

Supported OS

Supported OS –

* The supported OS depends on connected controllers (CPU-CA20, BX-320 etc.).

System specifications

Item Specifications
Output section
Number of output signal points 4points
Output format Reed relay contact (1 make output) output
Relay contact specifications Maximum allowable voltage) 125VAC, 30VDC (Max.)
Maximum switching current 2A(Max.)
Contact resistance 30mΩ or less
Response time 7msec or less
Mechanical life 20 million times or more (switching frequency: 180 times/minute)
Electrical life 100,000 times or more (switching frequency: 20 times/minute)
Relays used PA1a-5V
Common section
Internal power consumption 5VDC(±5%) 150mA(Max.) *1
Allowable distance of signal extension Approx. 50m (depending on wiring environment)
Physical dimensions (mm) 25.2(W) x 64.7(D) x 94.0(H) (exclusive of protrusions)
Weight (module itself) 100g
Module connection method Stack connection by means of a connection mechanism standard with the system.
Module installation method One-touch connection to 35mm DIN rails (standard connection mechanism provided in the system)
Applicable wire AWG 28 – 16
Applicableplug FRONT-MC 1,5/12-STF-3,81 (made by Phoenix Contact Corp.)
Standard VCCI Class A, FCC Class A, CE Marking (EMC Directive Class A, RoHS Directive), UKCA

*1 The stack connector accepts currents of up to 3.0A (Max.).

Caution

When connecting one of the modules to a controller module, the internal power consumption should be taken into account. If the total current exceeds the capacity of the power supply unit, the integrity of the operation cannot be guaranteed. For further details, please see the Controller Module manual.