This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

Used for Measuring Key Parameters of Components in the Wide Frequency Range of 10Hz-100kHz.
MICROTEST 6364 LCR Meter offers a frequency range of 10Hz to 100kHz. It can measure parameters such as |Z| (impedance), |Y| (admittance), θ (phase angle), X (reactance), R (series/parallel resistance), G (conductance), B (susceptance), L (inductance), D (dissipation factor), Q (quality factor), DCR (DC resistance), and C (capacitance). It supports communication interfaces such as RS-232, Handler, LAN, USB Host, GPIB, and can store test results and data via USB. With the optional PC connection software, it also enables sweep analysis capabilities. MICROTEST 6366 is an excellent choice for basic impedance measurements of electronic components.
LCR Meter
Model:
6364
Maker:
MICROTEST
Connect 636x series RS-232, GPIB or Handler to computer and using sweeping analysis.
Multi-step function up to 8 sets.
Features
- Test Frequency 10Hz-100kHz
- Output Impedance 100Ω
- Open Circuit/Short Circuit
- Meter Mode
- List Mode
- 7.0″ TFT, 800×480 color screen
- Four Parameters Displayed Simultaneously
- Comparator/BIN
- Basic Accuracy ±0.05%
- Using Graphical Analysis by PC Link
- RS-232、Handler、LAN、USB Host 、Handler、GPIB
Application
6364 test frequency 10Hz- 100kHz, the key parameters for inductance are Ls/Q/θ/Rs.
7.0”TFT, 800×480 color screen, and four parameters can displayed simultaneously.
USB Host can storage testing screen and data.
Methods for Measuring Motor Inductance
Specifications
Frequency Range | 10Hz-1MHz (Model 6367)
10Hz-500kHz (Model 6366) 10Hz-200kHz (Model 6365) 10Hz-100kHz (Model 6364) 10Hz-20kHz (Model 6363) 0.1Hz-200kHz (Model 6365A) |
Frequency Setting | Continuity |
Frequency Output Accuracy | ±0.01% |
Frequency Resolution | 5 Digits |
Basic Accuracy | ±0.05% |
AC Drive Level | Test Signal Voltage Level
10mV – 2Vrms |
Voltage Minimum Resolution
1mV |
|
DC Drive Level | Test Signal Voltage Level
10mV – 2V |
Voltage Minimum Resolution
1mV |
|
Output Impedance | 100Ω |
Measurement Mode | Meter mode, list mode |
Measurement Parameters | |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C |
Test Time | AC / DC test speed Max. 8mS |
Parameters | Range |
|Z| | 0.001mΩ – 99.999MΩ |
R, X | 0.001mΩ – 99.999MΩ |
|Y| | 0.1nS – 99.999S |
G, B | 0.1nS – 99.999S |
θ | ±0.001 ~ ±180.000deg |
Cs, Cp | 0.01pF – 9.9999F |
Ls, Lp | 0.1nH – 99.999KH |
D | 0.00001 – 9.9999 |
Q | 0.1 – 9999.9 |
Δ | -199.98 |
Rdc | 0.001mΩ – 99.999MΩ |
Measurement Circuit | Series/Parallel |
Correction | Open Circuit/Short Circuit |
Indicator | PASS/FAIL |
Test Range | Automatic/Lock |
BIN | ● |
List Mode | 8 sets |
Bulit-in Storge | 128 sets |
USB Host Storge | LCR setting documents, list mode setting document |
Trigger Test | Auto, manual, RS-232, GPIB, Handler |
Power Supply | Voltage:98-132Vac or 195-264Vac |
(Switchable) | |
Frequency:47-63Hz | |
Power consumption | 30VA |
Environment | Temperature:10℃-40℃ |
Humidity:20-90%RH | |
Dimension | 358x148x343 mm (W*H*D) |
Weight | 3 Kg |
Interface | RS-232、Handler、LAN、USB Host |
Display | Color Screen, 7″ TFT (800*480) |