This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
20 Channels Transformer Tester
The MICROTEST Transformer Tester provides comprehensive measurement of critical transformer parameters in a single instrument. Measurement items include inductance, leakage inductance, DC resistance, AC resistance, quality factor (Q), capacitance, turns ratio, and pin short‑circuit detection.It supports test frequencies of 200kHz, 500kHz, and 1MHz, with a built‑in LCR meter measurement mode. Equipped with F5620HR(P) / F5620(P) pneumatic test fixtures, the system offers 20 or 48 channels and supports 100mA DC bias testing. Customized test fixtures are available to meet specific customer requirements.
Transformer Analyzer 5260HR Series
Model:
5265N, 5266N, 5267N
Maker:
MICROTEST Corporation
Features
- Supports 20 Test Channels
- Basic Accuracy ±0.1%
- Open/Short Calibration Function
- Test Frequency: 10Hz~200kHz/ 500kHz/ 1MHz
- Meter Mode (Displays 4 Parameters)
- 0.1 mΩ Ultra‑Low DC Resistance Measurement (5265HR | 1A)
- Built‑in DC Withstand and Insulation Resistance Testing
- 100 mA DC Bias Current Testing (F5620 / F5620HR)
- USB Access for Settings, Test Data, and Screenshots
- DCW 10–100V High‑Sensitivity Insulation Testing for Dual‑Winding Magnetic Components
Specifications
| Series | 5260N | ||
| Model | 5265N | 5266N | 5267N |
| Test Frequency | 10Hz~200kHz | 10Hz~500kHz | 10Hz~1MHz |
| Channel | 20 | ||
| Frequency Resolution | 5 digits | ||
| AC Drive Level | 10mV~2Vrms | ||
| Turn Ratio Frequency | 50Hz~200kHz | ||
| Output Impedance | 100Ω | ||
| LCR Meter Function | ● | ||
| DC Bias Fixture | 100mA (F5620) | ||
| Safety Test | DC Withstand and Insulation Resistance Testing | |
| IR Resolution | – | |
| DC Output Voltage | – | |
| DC Leakage Current | – | |
| Measurement Parameters | Inductance (Ls), Impedance (Z), Capacitance (C), Reactance (X), Conductance (G), Susceptance (B), Admittance (Y), AC Resistance, Quality Factor (Q), Dissipation Factor (D), Phase Angle (θ), Ultra‑low DCR, Leakage Inductance (Lk), Turn Ratio, Balance, Short Circuit, DC Hipot/ Leakage Current, Insulation Resistance | |
| Parameters Measurement Ranges and Accuracy | ||||
| DCR | Series | 5260N | ||
| Range | 0.1mΩ~99.999MΩ | |||
| Accuracy | 0.01Ω~ 1Ω ±(1%+0.6mΩ)@ 0.1A (CC Mode) | |||
| 0.1% (CV Mode) | ||||
| Speed | 20ms | |||
| L, LK |
Basic Accuracy (AC parameter : 1KHz) |
0.1% | Speed | 20ms |
| C | 0.1% | 20ms | ||
| Q, D | 0.0005 | 20ms | ||
| Z, X, R | 0.1% | 20ms | ||
| Y | 0.1% | 20ms | ||
| θ | 0.03° | 20ms | ||
| Turn-Ratio | 0.5% | 50ms | ||
| Pin-Short | – | 15ms | ||
General
| Measurement Mode | LCR+Transformer |
| Measurement Circuit | Series/ Parallel |
| Correction | Open Circuit/ Short Circuit |
| Built‑in Storage | Testing files 128 sets |
| USB Host Storage | Depend on USB capacity |
| Operation | Auto, Manual, Remote Trigger |
| Interface | RS-232、Handler、LAN、USB Host、EXT.I/O |
| PC Link Software | ● |
| Power Supply | Voltage:90Vac~264Vac, Frequency:47~63Hz |
| Power Consumption | 70VA |
| Display | 800*480 Color LCD, 7″ TFT |
| Environment | Temperature:10℃~40℃, Humidity:20~90%RH |
| Dimension (W*H*D) | 358x148x343mm |
| Weight | 4.5Kg |