CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

MICROTEST LCR Meter 6365A / 6367A

Provides accurate basic measurements at 20k/100k/200k/500k/1 MHz.

The MICROTEST 6365A/6367A LCR Meter provides a frequency range of 0.1Hz to 200k/1MHz and is suitable for applications such as electrochemical impedance or battery material testing. With an extremely low starting frequency of 0.1Hz, it can accurately measure parameters such as |Z| (impedance), |Y| (admittance), θ (phase angle), X (reactance), R (series/parallel resistance), G (conductance), B (susceptance), L (inductance), D (dissipation factor), Q (quality factor), DCR (DC resistance), and C (capacitance). It supports communication interfaces such as RS-232, Handler, LAN, USB Host, GPIB(Optional), and allows storage of test screens and data via USB. With the optional PC connection software, it also enables sweep analysis capabilities.

LCR Meter 6365A/6367A

Model:

6365A, 6367A

Maker:

MICROTEST Corporation

Features

  • Ultra Low Frequency 0.1Hz-200k/1MHz
  • Output Impedance 100Ω
  • Open Circuit/Short Circuit
  • Meter Mode
  • List Mode
  • 7.0″ TFT, 800×480 color screen
  • Four Parameters Displayed Simultaneously
  • Comparator/BIN
  • Basic Accuracy ±0.05%
  • Using Graphical Analysis by PC Link
  • RS-232、Handler、LAN、USB Host 、Handler、GPIB(Optional)

Videos

Specifications

Model 6365A / 6367A
Frequency 0.1Hz-200kHz (6365A), 0.1Hz-1MHz(6367A)

SPEC

Frequency Setting Continuity
Frequency Output Accuracy ±0.01%
Frequency Resolution 5 Digits
Basic Accuracy ±0.05%
AC Drive Level Test Signal Voltage Level 10mV – 2Vrms
Voltage Minimum Resolution 1mV
DC Drive Level Test Signal Voltage Level 10mV – 2V
Voltage Minimum Resolution 1mV
Output Impedance 100Ω
Measurement Mode Meter mode, list mode
Measurement Parameters |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C
Test Time AC / DC test speed Max. 8mS

Measurement Parameters

Parameters Range
|Z| 0.001mΩ – 99.999MΩ
R, X 0.001mΩ – 99.999MΩ
|Y| 0.1nS – 99.999S
G, B 0.1nS – 99.999S
θ ±0.001 – ±180.000deg
Cs, Cp 0.01pF – 9.9999F
Ls, Lp 0.1nH – 99.999KH
D 0.00001 – 9.9999
Q 0.1 – 9999.9
Δ -9999% – 9999%
Rdc 0.001mΩ – 99.999MΩ

SYSTEM

Measurement Circuit Series/Parallel
Correction Open Circuit/Short Circuit
Indicator PASS/FAIL
Test Range Automatic/Lock
BIN ●
List Mode 8 sets
Bulit-in Storge 128 sets
USB Host Storge LCR setting documents, list mode setting document
Trigger Test Auto, manual, RS-232, GPIB, Handler
Power Supply Voltage:98-132Vac or 195-264Vac
(Switchable)
Frequency:47-63Hz
Power consumption 30VA
Environment Temperature:10℃-40℃
Humidity:20-90%RH
Dimension 358x148x343 mm (W*H*D)
Weight 3 Kg
Interface RS-232、Handler、LAN、USB Host
Display Color Screen, 7″ TFT (800*480)

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.