This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Provides a wide frequency range from 10 Hz to 30 MHz for impedance testing of components and materials.
The MICROTEST 6621 LCR Meter provides a wide frequency range of10Hz to 30MHz for measuring the impedance characteristics ofcomponents and materials. The measured parameters include |Z| , |Y| , θ , X ,R , G , B ,L , D , Q , DCR , C. It supports REMOTE/Handler/LAN/USB Host/USB Device/RS-232/GPIB(Optional)communication interfaces, making it compatible with automation equipment or human-machine interfaces (PLC).
LCR Meter 6621 Series
Model:
6621-1, 6621-3, 6621-5, 6621-10, 6621-20, 6621-30
Maker:
MICROTEST Corporation
Features
- Frequency range: DC, 10Hz to 1/3/5/10/20/30MHz
- Output Impedance 25Ω/100Ω, switchable
- Ultra-high measuring speed <3ms
- Basic accuracy up to ±0.05%
- Automatic Level Control Function
- Open circuit/Short circuit/Load Correction Function
- Built-in DC Bias Voltage ±12V (Option OP-662102)
- Support Meter Mode and List Mode
- Display 4 Sets of Parameters at Once
- Simultaneous AC/DC Measurement
- Comparator Function and Handler BIN Classification Function
- Support RS-232/ Handler/ LAN/ USB Host/ USB Device interfaces
- Supports GPIB Interface (Option OP-662101)
- Store Setup Files, Measurement Data, and Screenshots via USB
- Supports PC Link software
Specifications
| 6621 Series | ||||||
| Model | 6621-1 | 6621-3 | 6621-5 | 6621-10 | 6621-20 | 6621-30 |
| Frequency | 10Hz-1MHz | 10Hz-3MHz | 10Hz-5MHz | 10Hz-10MHz | 10Hz-20MHz | 10Hz-30MHz |
SPEC
| Model | 6621 | |
| Frequency Range | 10Hz-30MHz | |
| Frequency Setting | Continuity | |
| Frequency Resolution | ±0.01% | |
| Frequency Output Accuracy | 100mHz, 6-bit Frequency Input | |
| Basic Accuracy | typical ±0.05% | |
| AC Drive Level | Test Signal Voltage Level |
10mV-2Vrms(100Ω) 10mV-1Vrms(25Ω) |
| Voltage Minimum Resolution | 1mV | |
| Accuracy |
ALC ON:6% *Voltage ±2mV ALC OFF:10% *Voltage ±2mV |
|
| Test Signal Current Level | 200µA – 20mArms | |
| Current Minimum Resolution | 10µA | |
| Accuracy |
ALC ON:6%* Current±20µA ALC OFF:10%* Current±20µA |
|
| DC Drive Level | 1V (fixed) | |
| Output Impedance | 25Ω/100Ω(switchable) | |
| Measurement Mode | Meter mode, list mode | |
| Measurement Parameters | |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C | |
| Test Time (Fastest) | < 3mS | |
Measurement Parameters
| Parameters | Range |
| |Z| | 0.000 mΩ to 9999.99 MΩ |
| R, X | ± 0.000 mΩ to 9999.99 MΩ |
| |Y| | 0.00000 μS to 999.999 kS |
| G, B | ± 0.00000 μS to 999.999 kS |
| θRAD | ± 0.00000 to 3.14159 |
| θDEG | ± 0.000° to 180.000° |
| Cs, Cp | ± 0.00000 pF to 9999.99 F |
| Ls, Lp | ± 0.00 nH to 9999.99 kH |
| D | 0.00000 to 9999.99 |
| Q | 0.00 to 9999.99 |
| Δ | ± 0.00% to 9999.99% |
| Rdc | 0.00 mΩ to 99.9999 MΩ |
System
| Measurement Circuit | Series/Parallel |
| Correction | Open Circuit/Short Circuit/Load correction |
| Cable Compensation | 0 / 0.5 / 1 /2 (m) |
| BIN | ABS、ΔABS、Δ%、OFF |
| Comparator | 9 |
| List Mode | 50 groups of Multi-steps setting (Each group contains up to 15 steps) |
| Bulit-in Storge | 100 sets LCR setting documents, 50 groups of list mode setting |
| USB Host Storge | LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data |
| Trigger Test | Auto, manual, RS-232, Handler |
| Power Supply | Voltage:90-264Vac |
| Frequency:47-63Hz | |
| Power consumption | 30VA |
| Environment | Temperature:10℃-40℃ |
| Humidity:20-90%RH | |
| Dimension | 300×89.1×362.8 mm (W*H*D) |
| Weight | 3.4 Kg |
| Interface | RS-232、Handler、LAN、USB Host、USB Device |
| Display | 4.3″TFT,color screen (800*480) |