This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
20 Channels Transformer Tester
The MICROTEST 2-in-1 Transformer Integrated Test System is a comprehensive solution that combines low-voltage electrical characteristics testing and safety compliance testing. It offers 20 testing channels and integrates low-voltage testing (including inductance, leakage inductance, resistance, capacitance, etc.) with AC/DC withstand voltage insulation testing (up to 5000V/6000V). It ensures efficient and convenient testing for transformer products.
To measure the inductance value of a transformer, you can use an LCR meter, which offers selectable test frequencies including 200kHz, 500kHz, and 1MHz. It supports software that allows connection to a PC, enabling the storage of test data.
3-in-1 Transformer Testing System (Low Voltage+Safety+Impulse)
Model:
6265+7605+7721, 6266+7605+7721, 6267+7605+7721
Maker:
MICROTEST Corporation
Features
- Low Voltage Electrical Test
- Hi pot/ Insulation Test
- Impulse Test (Layer Short Circuit)
- 20 Channels
- Test Frequency (200k/500k/1MHz)
- AC Voltage Output 5000V
- DC Voltage Output 6000V
- Insulation Resistance 12000MΩ
Videos
Specifications
| Model | 3-in-1 (626X+7605+7721) | |||||
| Test Channel |
20 |
|||||
| Low Voltage Electrical Test | ||||||
| Model | 6265 | 6266 | 6267 | |||
| Frequency | 10Hz-200kHz | 10Hz-500kHz | 10Hz-1MHz | |||
| Frequency Resolution | 5 digits | |||||
| Basic Accuracy | ±0.1% | |||||
| AC Drive Level | 10mV-2Vrms | |||||
| DC Drive Level | 10mV-2V | |||||
| Output Impedance | 100Ω | |||||
| Turn |
Inductance or Voltage Test Frequency:50Hz-200kHz |
|||||
| Test Mode | Meter Mode / List Mode | |||||
| Parameters Measurement | Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、θ、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit | |||||
| L, LK | 0.1nH ~ 9999.99H | |||||
| C | 0.00001pF ~ 999.99mF | |||||
| Q,D | 0.00001 ~ 99999 | |||||
| Z,X,R | 0.00001Ω ~ 99.9999MΩ | |||||
| Y | 0.01nS ~ 99.9999S | |||||
| θ | -180°~ +180° | |||||
| DCR | 0.1mΩ ~ 99.999 MΩ | |||||
| Turn | 0.1 ~ 99999.9 turns | |||||
| Pin-Short | 12 pairs, between pin to pin | |||||
| Hi pot/ Insulation Test | ||||||
| Items | AC Hi pot | DC Hi pot | IR | |||
| Output Voltage | 10V-5000V | 10V-6000V | 10V-1000V | |||
| Voltage Resolution | 1V | 1V | 1V | |||
| Voltage Accuracy | ||||||
| Test Range | 0.001-31mA | 0.001-11mA | 1-12000MΩ | |||
| AC Arcing Detection | 0-20 | 0-10 | – | |||
| Measuring time | 0.1-999s | |||||
| Ramp Time | 0.1-10s | |||||
| Time Resolution | 0.1s | |||||
| Impulse Test | ||||||
| Impulse Voltage | 200V-5000V | |||||
|
Area Comparison |
When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer short. By calculating and comparing the deference of area between golden sample and DUT. |
|||||
|
Area Differential |
Add up the difference between normal wave and DUT wave call “Area differential”. By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap. |
|||||
|
Waveform Comparison |
Set a acceptable wave range, if the DUT’s wave is in this range shows “pass” otherwise,”fail”. |
|||||
| Corona | In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation. Detect the discharge phenomenon on the coil. |
|||||
| Flat |
If the layer short happened, the waveform will tremble. Therefore, the instrument will quantize and compared it. |
|||||
System
| Model | Transformer Tester | Impulse Tester | Hi pot Tester |
| 6265/6266/6267 | 7721 | 7605 | |
|
Built-in storage |
128 sets | 200 sets | – |
|
Power Supply |
Voltage 98Vac-132Vac or 195Vac-264Vac |
Voltage 115/230Vac±15% |
Voltage 98Vac-132Vac or 195Vac-264Vac |
| Frequency:47-63Hz | Frequency:50/60Hz±5% | Frequency:47-63Hz | |
|
Power consumption |
600VA/set | ||
|
Dimension (W*H*D) |
344x145x343 mm (W*H*D) | 435x190x522 mm | 435x145x500 mm(W*H*D) |
| Weight | 9 Kg | 14kg | 15kg |
| Interface | RS-232、Handler、LAN、USB Host、EXT. I/O | RS-232、Remote、Printer | RS-232、Remote、USB Host、USB Device、EXT.I/O |
| Display | Color Screen, 7″ TFT (800*480) |
5.7″ TFT (320*240) |
Color Screen, 4.3″ TFT (480*272) |