This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
20 Channels Transformer Tester
The MICROTEST 2-in-1 Transformer Integrated Test System is a comprehensive solution that combines low-voltage electrical characteristics testing and safety compliance testing. It offers 20 testing channels and integrates low-voltage testing (including inductance, leakage inductance, resistance, capacitance, etc.) with AC/DC withstand voltage insulation testing (up to 5000V/6000V). It ensures efficient and convenient testing for transformer products.
To measure the inductance value of a transformer, you can use an LCR meter, which offers selectable test frequencies including 200kHz, 500kHz, and 1MHz. It supports software that allows connection to a PC, enabling the storage of test data.
2-in-1 Transformer Testing System (Low Voltage+Safety)
Model:
6265+7631, 6266+7631, 6267+7631
Maker:
MICROTEST Corporation
Features
- Supports 20 Test Channels
- Basic Accuracy ±0.1%
- Open/Short Calibration Function
- Test Frequency: 10Hz~200kHz/ 500kHz/ 1MHz
- Meter Mode (Displays 4 Parameters)
- 0.1 mΩ Ultra‑Low DC Resistance Measurement (5265HR | 1A)
- Built‑in DC Withstand and Insulation Resistance Testing
- 100 mA DC Bias Current Testing (F5620 / F5620HR)
- USB Access for Settings, Test Data, and Screenshots
- DCW 10–100V High‑Sensitivity Insulation Testing for Dual‑Winding Magnetic Components
Specifications
| Model | 2-in-1 (626X+7631) | |||||
| Test Channel | 20 | |||||
| Low Voltage Electrical Test | ||||||
| Model | 6265 | 6266 | 6267 | |||
| Frequency | 10Hz-200kHz | 10Hz-500kHz | 10Hz-1MHz | |||
| Frequency Resolution | 5 digits | |||||
| Basic Accuracy | ±0.1% | |||||
| AC Drive Level | 10mV-2Vrms | |||||
| DC Drive Level | 10mV-2V | |||||
| Output Impedance | 100Ω | |||||
| Turn |
Inductance or Voltage Test Frequency:50Hz-200kHz |
|||||
| Test Mode | Meter Mode / List Mode | |||||
| Parameters Measurement | Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、θ、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit | |||||
| L, LK | 0.1nH ~ 9999.99H | |||||
| C | 0.00001pF ~ 999.99mF | |||||
| Q,D | 0.00001 ~ 99999 | |||||
| Z,X,R | 0.00001Ω ~ 99.9999MΩ | |||||
| Y | 0.01nS ~ 99.9999S | |||||
| θ | -180°~ +180° | |||||
| DCR | 0.1mΩ ~ 99.999 MΩ | |||||
| Turn | 0.1 ~ 99999.9 turns | |||||
| Pin-Short | 12 pairs, between pin to pin | |||||
| Hi pot/ Insulation Test | ||||||
| Items | AC Hi pot | DC Hi pot | IR | |||
| Output Voltage | 10V-5000V | 10V-6000V | 10V-1000V | |||
| Voltage Resolution | 1V | 1V | 1V | |||
| Voltage Accuracy | ||||||
| Test Range | 0.001-31mA | 0.001-11mA | 1-12000MΩ | |||
| AC Arcing Detection | 0-20 | 0-10 | – | |||
| Measuring time | 0.1-999s | |||||
| Ramp Time | 0.1-10s | |||||
| Time Resolution | 0.1s | |||||
System
| Model | Transformer Tester | Hi pot Tester |
| 6265/6266/6267 | 7631 | |
| Built-in storage | 128 sets | 15 sets |
| PC Link-storage | Unlimited storage | |
| Power Supply |
Voltage 98Vac-132Vac or 195Vac-264Vac |
Voltage 98Vac-132Vac or 195Vac-264Vac |
| Frequency:47-63Hz | Frequency:47-63Hz | |
| Power consumption | 400VA/set | |
| Dimension (W*H*D) | 344x145x343 mm (W*H*D) | 435x145x500 mm (W*H*D) |
| Weight | 9 Kg | 15kg |
| Interface | RS-232、Handler、LAN、USB Host、EXT. I/O | RS-232、Remote、USB Host、USB Device、EXT.I/O |
| Display | Color Screen, 7″ TFT (800*480) |
Color Screen, 4.3″ TFT (480*272) |