This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Optocoupler isolated input (compatible with current sink output/current source output). Relay outputs (Form C) with independent common
This product is an USB 2.0-compliant digital I/O unit that extends the input function of digital signal from the USB port of PC and output signals to SPDT relay contacts. This product is compatible with input digital signals at 12 - 24VDC which features 8 channels of Opto-coupler isolated inputs (compatible with current sink output/current source output) and 8 channels of SPDT relay outputs with independent common. Compact design not restricting installation location (188.0(W) x 78.0(D) × 30.5(H)) makes it easy to install the product within the panel or device using DIN rail mounting jigs, or on the floor or wall. Windows/Linux device driver is supported with this product.
Digital I/O USB I/O Unit 8ch/8ch (Isolated 12 - 24VDC / Power Relay - 240VAC - 28VDC) - The N Series
Model:
DIO-0808RN-USB
Maker:
CONTEC Co., Ltd.
Features
- Optocoupler isolated input (compatible with current sink output/current source output)
This product has 8 channels of Optocoupler isolated inputs (compatible with current sink output/current source output) whose response speed is 200µsec, supporting driver voltages of 12 – 24 VDC for input. 8 channels share one common. - Relay outputs (Form C) with independent common
This product has 8 channels of SPDT relay outputs (Form C) with independent common. Independent common terminal provided per channel, capable of supporting a different external power supply. High-capacity output rating is designed to be a maximum of 6A 240V (AC), 5A 28V (DC) per channel. - Compact design not restricting installation location (188.0(W) x 78.0(D) x 30.5(H))
Compact design of 188.0(W) × 78.0(D) × 30.5(H) does not require special installation location. - Easy-to-wire terminal connector adopted
Adoption of terminal connector (with screws) enables to achieve easy wiring. - Diverse installations such as screw fastening, magnet, DIN rail are possible
Installation on the floor / wall /ceiling is possible by screw fastening, magnet, rubber feet, etc. In addition, DIN rail mounting mechanism is equipped as standard with the product, making it easy to install the product within the panel or the device. - Windows/Linux support device driver
Using the device driver API-TOOL makes it possible to create applications of Windows/Linux. In addition, a diagnostic program by which the operations of hardware can be checked is provided.
Specifications
Add-on Module
| Series | USB N(Compact) |
|---|---|
| Bus Specification | USB |
| Size | N Type |
| Used Connector | 4x 3.5mm-pitch 10-pin 2-piece terminal block |
Digital I/O
| Input Channels | 8-ch |
|---|---|
| Output Channels | 8-ch |
| Bi-directional I/O Channels | – |
| Response Time (Input) | 200μsec (max.) |
| Response Time (Output) | ON: 10msec (max.) / OFF: 5msec (max.) |
| Operating Voltage (Input) | 12 to 24VDC |
| Operating Voltage (Output) | to 240VAC / to 28VDC |
| Input Circuit | Opto-isolated input (for both current sink and source output) |
| Output Circuit | Power relay output (SPDT type-C contact) |
| Built-in Power Supply | – |
Supported OS
| Supported OS | Windows 11 (64-bit); Windows 10 IoT Enterprise LTSC 2021 (64-bit); Windows 10 IoT Enterprise 2019 LTSC (64-bit); Windows 10 IoT Enterprise LTSB 2016 (64-bit); Windows 10 (64-bit); Windows 10 (32-bit); Windows 8.1 (64-bit); Windows 8.1 (32-bit); Windows 7 (64-bit); Windows 7 (32-bit); Windows Vista (64-bit); Windows Vista (32-bit); Windows XP (64-bit); Windows XP (32-bit); Windows 2000 (32-bit); Windows Server 2022; Windows Server 2019; Windows Server 2016 ; Windows Server 2012 R2; Windows Server 2008 (64-bit); Windows Server 2008 (32-bit); Windows Server 2003 (64-bit); Windows Server 2003 (32-bit); Linux |
|---|
* The supported OS differs depending on the software used for this product. For more details about supported OS and distribution, please refer to the software Readme or online help.
System specifications
| Item | Specifications | ||
|---|---|---|---|
| Input | Type | Opto-isolated input (Compatible with current sink / current source output) (Negative logic *1) | |
| Number of Channels | 8 channels (1 common) | ||
| Input resistance | 4.7kΩ | ||
| Current required to turn ON | 2.0mA or more | ||
| Current required to turn OFF | 0.16mA or less | ||
| Response time | 200µsec within *2 | ||
| Isolated voltage | 500Vrms | ||
| External circuit power supply *3 | 12 – 24VDC(±10%) | ||
| Output | Type | SPDT Relay Output (Form C) | |
| Number of Channels | 8 channels (independent common) | ||
| Relay Contact Spec. | Max. rating capacity | 6A 240VAC, 5A 28VDC (load resister) | |
| Max. permitted voltage | 240V (Max.) *4, *5 | ||
| Max. Carry Current | 5A (Max.) | ||
| Contact resistance (Initial state) | 100mΩ Max. | ||
| Operate time | Within 10ms | ||
| Release time | Within 5ms | ||
| Mechanical Life Expectancy | 10,000,000 operations min or more Switching times : 300 operations/min |
||
| Electrical Lifetime | 50,000 operations min. Switching times : 30 operations/min |
||
| Relay Type | G6RL-1 | ||
| USB section | Bus specification | USB Specification 2.0/1.1standard | |
| USB transfer rate | 12Mbps (Full-speed), 480Mbps (High-speed) *6 | ||
| Power supply | Bus power | ||
| Common | Number of terminals used at the same time | 127 terminals (Max.) *7 | |
| Allowable distance of signal extension | Approx. 50m (depending on wiring environment) | ||
| Current consumption | 5VDC 430mA (Max.) | ||
| Physical dimensions (mm) | 188.0(W)×78.0(D)×30.5(H) (No protrusions) | ||
| Weight | 300g (Not including the USB cable, attachment, connector) | ||
| Attached cable | USB cable 1.8m | ||
*1 Data “0” and “1” correspond to the High and Low levels, respectively.
*2 The Opto-coupler’s response time comes.
*3 External circuit power supply is required.
*4 Please don’t exceed either max. permitted voltage or max. rating capacity of the use relay when using it by the voltage that exceeds 28VDC. Doing so can cause a malfunction.
*5 The potential difference between channels must not exceed 240V in the maximum. Doing so can cause a malfunction.
*6 This depends on the PC environment used (OS and USB host controller).
*7 As a USB hub is also counted as one device, you cannot just connect 127 USB unit.