CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

ANRITSU METER Handheld Thermometer Model HR Series HR-1550K / HR-1550E

Memory model. Record measurement results and transfer data to PC

Measurement Range
K -200 to 1370°C / E -200 to 800°C
 
HOLD
The thermometer stops measurement by the HOLD key and holds the present readings.
 
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
 
Resolution change
Press the [RESO] key to change the resolution of readings.
 
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
 
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
 
Memory function
Stores readings at user-selected time intervals. User specified time interval and the remaining amount of memory are displayed on the sub-display.

Made in Japan
Large easy-to-read LCD display

Handheld Thermometer Model HR Series

Model:

HR-1550K / HR-1550E

Maker:

ANRITSU METER CO., LTD.

Features

  • Accuracy : ±(0.05% of reading + 0.2℃ at over 0℃)
  • Resolution : 0.1℃ or 1℃ (Changeable)
  • Memory function (19999 data can be saved)
  • Interval : 1, 5, 10, 30s, 1, 5, 10, 30, 60min selectable
  • Dimensions : 82(W)×166(H)×36(D)
  • Weight : 350g (including batteries)
  • Power supply : 4AA Alkaline dry batteries or AC adaptor
  • Battery life : approx.550hours
  • Accessories : Test report, Soft case, Hand strap, CD-ROM, 4AA Alkaline batteries, Manual, Communication cable

Line up

Model

HR-1100
HR-1150
HR-1650

HR-1200
HR-1250
HR-1750
HR-1300
HR-1350
HR-1301
HR-1351
HR-1400
HR-1450
HR-1500
HR-1550
Display LCD  LED LCD 
Waterproof specifications/Equivalent to IPX5 ✔ ✔ – – ✔ –
Input connector ASP model:HR-1*0* /ANP model:HR-1*5*
Input type Thermocouple Input: Type E, K (Not switchable)
Channel 1ch
Signal source resistance MAX.1 Kohm
Measurement Range 1°C Resolution E -200~800°C
K -200~1370°C
0.1°C Resolution E -104.9~504.9°C(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)
K -104.9~504.9°C(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)
Measurement Accuracy 1°C Resolution 0°C~ ±(0.1% of reading +1°C)
~0°C ±(0.5% of reading +1°C)
0.1°C Resolution 0°C~ ±(0.05% of reading + 0.2°C)
~0°C ±(0.15% of reading + 0.2°C)
Reference junction compensation accuracy ±0.2°C at 25°C±10°C 

Temperature Coefficient*1

HR-1*1*:±0.02×Δt°C/HR-1*5*:±0.03×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C)
Operation Environment 0 to 50°C, 0 to 80%RH (Non condensing)
Storage Environment -20 to 50°C, 0 to 85%RH (Non condensing)
Battery life approx.900h approx.900h approx.600h approx.20h*2 approx.300h approx.550h
Power supply(Dry battery) 4 AA Alkaline batteries
Power supply(AC power) – –

available

– available
Sampling rate approx.200ms
Linearlizer Digital Linearizer method (Compliant with IEC 60584-1 (2013))
Dimensions(mm) approx. 82(w)×166(H)×36(D)  [Protruded parts excluded]
Weight approx. 350g [Include Batteries]
Supplied accessories Manual,Test report,Soft case, Hand strap,4 AA Alkaline batteries
Optional accessories – – Alarm output cable – Communication cable,software
  Analog output cable – –
Alarm Output – –

✔ TABLE1

✔ TABLE1 –

‐

Analog Output – – – ✔ TABLE2

‐

‐

Memory function – – – – – ✔ TABLE3
Compatible standards(CE) EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)

RoHS:IEC EN 63000:2018

*1 Only when the temp. exceeds 25°C ±10°C
*2 Approx. 400h when the analog output is switched always off.

Videos

Specifications

Model HR-1550
Display LCD
Waterproof specifications –
Input connector ANP
Input type Thermocouple Input: Type E, K
Channel 1ch
Signal source resistance MAX.1k ohm
Measurement Range 1°C Resolution E -200 to 800°C
K -200 to 1370°C
0.1°C Resolution E

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

K

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

Measurement Accuracy 1°C Resolution 0°C to ± (0.1% of reading +1°C)
to 0°C ± (0.5% of reading +1°C)
0.1°C Resolution 0°C to ± (0.05% of reading + 0.2°C)
to 0°C ± (0.15% of reading + 0.2°C)
Reference junction compensation accuracy ±0.2°C at 25°C±10°C
Temperature Coefficient*1

±0.03×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.5°C is added at room temp. of 0°C or 50°C)

Operation Environment

0 to 50°C, 0 to 80%RH (Non condensing)

Storage Environment

-20 to 50°C, 0 to 85%RH (Non condensing)

Battery life approx.550h
Power supply(Dry battery) 4 AA Alkaline batteries
Power supply(AC power) option available
Sampling rate approx.200ms
Linearlizer Digital Linearizer method (Compliant with JIS C1602-2015)
Dimensions(mm) approx. 82(w)×166(H)×36(D)  [Protruded parts excluded]
Weight approx. 350g [Include Batteries]
Supplied accessories Manual,Test report,Soft case,
Hand strap,4 AA Alkaline batteries
Optional accessories Communication cable, Software(AMS-350)
Memory function TABLE1
Compatible standards

EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)

RoHS:IEC EN 63000:2018

*1 Only when the temp. exceeds 25°C±10°C

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.