This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Data recorded by simple operation can be transferred to PC with dedicated software for analysis processing.
Measurement Range
E -200~800℃ / K -200~1370℃ / J -200~1100℃ / T -200~400℃ / R 0~1760℃
Channel
12ch (ANP connector (both poles are coper))
Input Type
Thermocouple (multi-input : Type E,K,J,T,R)
Voltage input
Interface
USB2.0(microーB)
Interval
(The following numbers are time of interval that can be set.)
less than 1s : 0.2s ~ 0.99s Over 1s : 1s ~ 99m 59s
Compact Thermologger AM-9000 Series
Model:
AM-9300
Maker:
ANRITSU METER CO., LTD.
Features
- Multi-input type. Type K, E, J, T, R changeable
- Number of inputs : 12ch
- Accuracy : ±0.5℃ (at 0.0~200.0℃)
- Measurement interval : 0.2sec to 99min 59sec
- Memory capacity : 120,000 data
- Dimensions : 96(W)×160(H)×60(D), weight : 540g
- Power supply : 4 AA Alkaline batteries or AC adaptor
- Accessories : Test report, Soft case, Hand strap
- 4AA Alkaline batteries, Manual, communications cable
Specifications
| Model | AM-9300 |
| Number of inputs | 12ch : ANP connector (Miniature Plug) |
| Input connector | ANP connector (both poles are coper) |
| Input type | Temperature:Multi-input (E・K・J・T・R) DC Voltage:V |
| Measurement range | Temperature: TABLE Ⅰ DC Voltage : ±20.000V |
| Resolution | Temperature: 0.1℃/1℃ DC Voltage : 0.001V |
| Measurement accuracy | Temperature: TABLE Ⅱ DC Voltage : ±(0.05% of reading +0.003V) |
| Memory capacity | 120,000 data |
| Interface | USB2.0 (micro-B) |
|
Dimensions |
96(W)×160(H)×60(D) |
| Weight(Including dry batteries) | approx.540g |
| Reference junction compensation accuracy |
±0.5℃(at 25℃±10℃) |
| Temperature coefficient |
± (0.04 × Δt ℃) *1 |
| Time interval |
0.2 second to 99 minutes 59 seconds |
| Signal source resistance | 500Ω or less (measurement interval 1 second or more)/100Ω or less (measurement interval less than 1 second) |
| Safe excitation voltage | Between input pins on same channels :±30VDC,Between input pins on adjacent channels : 150Vp-p |
| Linearlizer | Digital Linealizer method (Compliant with JIS C1602-2015) |
| Display | Graphic liquid crystal display, 128×64 dots |
| Environment operational Environment storage |
Operation : 0〜40℃、15〜80%RH (Non condensing) |
| Battery life | TABLE Ⅲ |
| Power supply | 4 AA Alkaline batteries(Supplied accessories) or AC-Adaptor(Optional accessories) |
| Supplied accessories | Manual, Test report, Softcase, Communications cable, 4 AA Alkaline batteries |
| Optional accessories | Special data analysis software, AC-Adaptor, Carrying case |
| Compatible standards | CE Marking, RoHS2 |
*1 When the ambient temperature is other than from 15℃ to 35℃, “the excess temperature from the ambient temperature Δt℃” x 0.04 is added to the measurement accuracy.
TABLE Ⅰ : Measurement Range
| Thermocouple type | Measurement range |
| E | -200 to 800°C |
| K | -200 to 1370°C |
| J | -200 to 1100°C |
| T | -200 to 400°C |
| R | 0 to 1760°C |
TABLE Ⅱ : Measurement accuracy
In the environment of 25 ℃ ± 10 ℃, when the measurement interval is 1 second or more without including the reference junction compensation accuracy.
| Thermocouple type | Accuracy compensation range | Measurement accuracy |
| E,K,J,T | -200.0~-100.1℃ | ±1.5℃ |
| -100.0~-0.1℃ | ±1.0℃ | |
| 0.0~200.0℃ | ±0.5℃ | |
| 200.1~500.0℃ | ±0.7℃ | |
| 500.1℃ or more | ±1.0℃ | |
| R | 0.0℃~500.0℃ | ±2.0℃ |
| 500.1℃ or more | ±2.5℃ |
*If the measurement interval is less than 1 sec, add ± 0.5 ℃ at type E ・ K ・ J ・ T and add ± 1.0℃ at type R
TABLEⅢ 12ch model standard time for continuous use (at 25 ℃, using alkaline AA batteries)
| Setting interval | 0.2sec | 1sec | 10sec |
| AM-9000 Series | approx. 50 hours | approx. 55 hours | approx. 140 hours |
* If the number of used channels is less than 12, the usable time will be longer.