This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
High-Capacity Wide-Range DC Power Supply (CV/CC/CP)
The PXT Series high-capacity DC power supply delivers 20 kW in a compact 3U size, with a voltage range of 500V-40A to 166.6V-120A. It's ideal for harsh conditions, operating up to 50°C due to advanced heat dissipation. Featuring low ripple noise and quick transient response, it allows seamless integration with LAN, USB, and RS232C interfaces. Scalable up to 500 kW via parallel operation, the PXT Series is versatile and reliable for demanding electric applications.
It can be used not only as a stand-alone device, but also for integration into test equipment. Furthermore, its excellent heat dissipation design enables it to achieve a guaranteed Operating temperature of 50°C, making it suitable for harsh high-temperature operating environments. The system is also highly scalable, and its capacity can be increased up to 500 kW through Parallel operation (up to 25 units).
High-Capacity Wide-Range DC Power Supply PXT Series
Model:
PXT20K-500, PXT20K-1000, PXT20K-1500
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
- Maximum 20 kW output in a 3U size
- Supports a maximum voltage of 1500 V
- Bleeder ON/OFF function
- Output ON/OFF delay function
- Continuous full-load operation at ambient temperatures as high as 50°C
- Up to 25 units (500 kW) can be operated in parallel
*Please consult with us if you would like to use 10 or more units in Parallel operation. - One-control parallel operation function (up to 25 units of the same model)
- Touch panel for intuitive operation
- LAN, USB, RS232C, external analog control (isolated type) standard
Line up
| SKU | Output Power [W] | Output CV [V] | Output CC [A] |
|---|---|---|---|
| PXT20K-500 | 20kW | 0 〜 500 | 120 |
| PXT20K-1000 | 20kW | 0 〜 1000 | 60 |
| PXT20K-1500 | 20kW | 0 〜 1500 | 30 |
Videos
Specifications
| Item | PXT20K-500 | PXT20K-1000 | PXT20K-1500 | |
|---|---|---|---|---|
| Weight | Approx. 38 kg (83.78 lbs) | Approx. 38 kg (83.78 lbs) | Approx. 37 kg (81.57 lbs) | |
| Dimensions | 430 (16.93)(MAX455 (17.91))W×128 (5.04)(MAX160 (6.30))H×720 (28.35)(MAX980 (38.58))Dmm(mm (inches)) Refer to Outline Drawing | |||
| Environmental conditions | Operating environment | Indoor use, overvoltage category II | ||
| Operating temperature | 0 °C to +50 °C (32 °F to +122 °F) | |||
| Operating humidity | 20 %rh to 85 %rh (no condensation) | |||
| Storage temperature | -25 °C to +60 °C (-13 °F to 140 °F) | |||
| Storage humidity | 90 %rh or less (no condensation) | |||
| Altitude | Up to 2000 m | |||
| Cooling method | Forced air cooling using fan | |||
| Accessories | AC INPUT terminal cover, External control connector kit (1 set), Chassis connection wire, DC OUTPUT terminal cover, DC OUTPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pieces), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 copy), Getting Started Guide (1 copy), Heavy object warning label (1 piece) | |||
| Withstanding voltage | Between input and GND | 2200 Vac for 1 minute | ||
| Between input and output | ||||
| Between output and GND | 1800 Vdc for 1 minute | 1800 Vdc for 1 minute | 3000 Vdc for 1 minute | |
| Insulation resistance | Between input and GND | 30 MΩ, 500 Vdc | ||
| Between input and output | 30 MΩ, 1000 Vdc | |||
| Isolation voltage | ± 1000V | ± 1000V | +2000 V/-1000 V | |
| Electromagnetic compatibility (EMC)*1*2 | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 61326-1 (Class A*3) |
|||
| Safety*1 | Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/35/EU*2 EN 61010-1 (Class I*4, Overvoltage category II, Pollution Degree 2*5) |
|||
*1 Does not apply to specially ordered or modified products.
*2 Only for models with CE mark / UKCA mark on their body.
*3 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*5 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.