This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
New Flagship Bench-top DC Power Supply – 400W Model
The PWR-01 is a series of high performance, multifunctional, compact, wide-range DC power supplies. It consists of 16 models in total with 4 maximum voltage outputs (L, ML, MH, and H) and 4 maximum power outputs (400 W, 800 W, 1200 W and 2000 W).
The series is equipped with LAN (LXI), USB, and RS232C as standard interfaces that are essential for system integration. The PWR-01 also features front-facing output terminals, variable internal resistance, bleeder ON/OFF functions, CC/CV priority switching function, synchronized operation, various protections, and programmable internal memory.
Compact Wide Range DC Power Supply PWR-01 Series – 400W Model
Model:
PWR801L, PWR801ML, PWR801MH, PWR801H
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
- Sequence function (supports triggered synchronization)
- Variable internal resistance function
- LAN (LXI compliant) /USB/RS232C as standard interface
- A virtual multi-channel bus (VMCB) function makes multi-channel operation more efficient
- A wide range of voltage and current settings can be combined within its output power rating (3 to 4 times)
- Supporting universal input voltage (85 V to 265 V)
- CONFIG setting shortcut function and display (Up to three parameters can be registered.)
- Setting preset memory function (3 combinations of settings for voltage, current, OVP, OCP, and UVL)
- Bleeder (sink) can be turned ON/OFF, with an even stronger bleeder mode setting available
- Output ON/OFF delay function
- Soft start/stop function
- Durable Performance Operating temperature guaranteed up to 50 °C (122 °F). (Storage temperature is -25 °C to +60 °C (-13 °F to 140 °F).)
Line up
| SKU | Output CV [V] | Output CC [A] | Output Power [W] |
|---|---|---|---|
| PWR401L | 0 to 40V | 0 to 80A | 800W |
| PWR401ML | 0 to 80V | 0 to 40A | 800W |
| PWR401MH | 0 to 240V | 0 to 10A | 800W |
| PWR401H | 0 to 650V | 0 to 3.7-A | 800W |
Videos
Specifications
| Item/Model | 400W | 800W | 1200W | 2000W | |
|---|---|---|---|---|---|
| Weight (main unit only) | Approx. 3 kg (6.61 lb) | Approx. 5.5 kg (12.13 lb) | Approx. 7.5 kg (16.53 lb) | Approx. 13 kg (28.66 lb) | |
| Dimensions | See the outline drawing.(Catalogue p15) | ||||
| Environmental conditions | Operating environment | Indoor use, overvoltage category II | |||
| Operating temperature | 0 °C to +50 °C (32 °F to +122 °F) | ||||
| Operating humidity | 20 %rh to 85 %rh (no condensation) | ||||
| Storage temperature | -25 °C to +60 °C (-13 °F to 140 °F) | ||||
| Storage humidity | 90 %rh or less (no condensation) | ||||
| Altitude | Up to 2000 m | ||||
| Cooling method | Forced air cooling using fan | ||||
| Grounding polarity | Negative grounding or positive grounding possible | ||||
| Isolation voltage | L/ ML/ MH type: ±500 Vmax H type: ±800 Vmax | ||||
| Withstanding voltage | Across the primary circuit and chassis | No abnormalities when 1500 Vac is applied for 1 minute | |||
| Across the primary and secondary circuits | L/ ML/ MH type: No abnormalities when 1650 Vac is applied for 1 minute | ||||
| H type: No abnormalities when 1900 Vac is applied for 1 minute | |||||
| Across the secondary circuit and chassis | L/ ML/MH type: No abnormalities when 2300 Vdc is applied for 1 minute | ||||
| H type: No abnormalities when 2640 Vdc is applied for 1 minute | |||||
| Insulation resistance | Across the primary circuit and chassis | 100 MΩ or more (70 %rh or less) at 500 Vdc | |||
| Across the primary and secondary circuits | L/ ML/ MH type: 100 MΩ or more (70 %rh or less) at 500 Vdc | ||||
| H type: 100 MΩ or more (70 %rh or less) at 1000 Vdc | |||||
| Across the secondary circuit and chassis | L/ ML/ MH type: 40 MΩ or more (70 %rh or less) at 500 Vdc | ||||
| H type: 40 MΩ or more (70 %rh or less) at 1000 Vdc | |||||
| Accessories |
|
||||
| Electromagnetic compatibility *1 *2 |
Complies with the requirements of the following directive and standard.
Applicable under the following conditions: |
||||
| Safety *1 | Complies with the requirements of the following directive and standard. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *5 , Pollution Degree 2 *6) |
||||
*1. Does not apply to specially ordered or modified products.
*2. Limited to products that have a CE/UKCA mark. Does not apply unless a core is attached to the J1 connector cable.
*3. This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4. This is a Group 1 instrument. This product does not generate and/or use intentionally radiofrequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.
*5. This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*6. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.