This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Three models with 2, 3 and 4 outputs. Ideal for use in research and development and on production lines
The PMX-Multi series is a multi-channel DC power supply with isolated outputs on each channel. The PMX32-3DU (2ch), PMX32- 3TR (3ch), and PMX32-2QU (4ch) are all capable of simultaneous output in all channels and come with an output tracking feature.
Also, channels 1 & 2 of each model can be easily connected in either series or parallel to
increase the output voltage/current at the press of a button. LAN (LXI Compliant), USB, and
RS232C are included as standard digital interfaces for easy system integration.
The PMX-Multi benefits from a low noise, series regulator design that makes this series the
perfect choice for experiments involving transistors, IC circuits, and op amp circuits as well
as R&D and production line applications.
Three models with 2, 3 and 4 outputs
Each output is isolated
High setting resolution (Voltage: 1 mV, Current: 0.1 mA)
Tracking control in all channels
Simultaneous display of all channel statuses
ON/OFF delay of each output
Simple series/parallel connection between channels (CH1 & CH2)
LAN (LXI Compliant)/USB/RS232C standard interface
Turning output on and off using an external contact
Remote sensing function
Key lock, 3-point preset memory function
High quality LCD panel for improved visibility
Compact Multi-Output DC Power Supply PMX-Multi Series
Model:
PMX32-3DU, PMX32-3TR, PMX32-2QU
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
- Three models with 2, 3 and 4 outputs.
- Each output is isolated.
- High setting resolution. (Voltage: 1 mV, Current: 0.1 mA)
- Tracking control in all channels.
- Simultaneous display of all channel statuses.
- ON/OFF delay of each output.
- Simple series/parallel connection between channels. (CH1 & CH2)
- LAN (LXI Compliant)/USB/RS232C standard interface.
- Turning output on and off using an external contact.
- Remote sensing function.
- Key lock, Preset memory function. (3 slots)
- High quality LCD panel for improved visibility.
Videos
Specifications
| Model | PMX32-3DU | PMX32-3TR | PMX32-2QU | |
|---|---|---|---|---|
| Weight (main unit only) | Approx. 13 kg (28.66 lb) | |||
| Dimensions (mm(inches)) | 214(8.46)W×124(4.88)(MAX155(6.10))H×400(15.75)(MAX435(17.13))D | |||
| Environmental conditions | Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | ||
| Operating humidity range | 20 %rh to 85 %rh (no condensation) | |||
| Storage temperature range | -25°C to 70°C (-13°F to 158°F) | |||
| Storage humidity range | 90 %rh or less (no condensation) | |||
| Installation location | Indoor use, altitude of up to 2000 m, overvoltage category II | |||
| Isolation voltage | Between channel | ±70 Vdc | ||
| Between the output and chassis | ±70 Vdc | |||
| Withstanding voltage | Between the primary circuit and chassis | No abnormalities at 1500 Vac for 1 minute. | ||
| Between the primary and secondary circuits | No abnormalities at 2600 Vac for 1 minute. | |||
| Between the secondary circuit and chassis | No abnormalities at 1500 Vdc for 1 minute. | |||
| Insulation resistance | Between the primary circuit and chassis | 500 Vdc, 30 MΩ or more | ||
| Between the primary and secondary circuits | ||||
| Between the secondary circuit and chassis | ||||
| Between channel | ||||
| Cooling system | Forced air cooling using a fan motor | |||
| Common | All channels are independent. The withstanding voltage between channels is ±70 V. | |||
| Grounding polarity | Negative grounding or positive grounding possible | |||
| Accessories | Power cord: 1 pc. (The attached power cord varies depending on the shipment destination.) Output terminal cover set: 1 set, CD-ROM: 1 disc, Packing list: 1 copy, Safety Information: 1 copy | |||
| Electromagnetic compatibility (EMC) *1 *2 | Conforms to the requirements of the directive and standard below. EMC Directive 2014/30/EU EN61326-1 (Class A *3), EN 55011(Class A *3, Group 1 *4) EN 61000-3-2, EN 61000-3-3 Applicable under the following conditions The maximum length of all cabling and wiring connected to the PMX-A must be less than 3 m. |
|||
| Safety *1 | Conforms to the requirements of the directive and standard below. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *5 , Pollution Degree 2 *6) |
|||
*1 Does not apply to specially ordered or modified products.
*2 Only on models that have the CE marking on the panel.
*3 This product confirms to Class A. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4 This is a Group 1 instrument. This product does not generate and/or use intentionally radiofrequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.
*5 This product confirms to Class I. Be sure to ground the protective conductor terminal of this product. If not grounded properly, safety is not guaranteed.
*6 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.