This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
8 Inputs Channels that Provide World Class Flexibility and Accuracy
The PW8001 sets a new benchmark for complete power analysis solutions with Hioki being the only manufacturer that offers industry-leading power analyzers and a wide portfolio of high-accuracy current sensors both developed and manufactured by Hioki. This enables to align their performance and results in more accurate and stable measurements from DC to high frequencies and low power factor measurements thanks to functions like the automatic phase shift correction.
Upcoming industry challenges are anticipated with the ability to measure even large currents at voltages up to 1500 V, 15 MS/s sampling rate and multi-channel measurement target applications using SiC/GaN semiconductors from automobile electrification, smart grids and reactors to renewable energy supply sources.
Power Analyzer
Model:
PW8001
Maker:
HIOKI E.E. CORPORATION
Features
- World-class measurement accuracy: Basic accuracy ±0.03%, DC accuracy ±0.05%, 50 kHz accuracy 0.2% (*1)
- Accurate capture of power fluctuations caused by high-speed switching: Sampling performance 18-bit, 15 MHz, Noise Resistance (CMRR) 110 dB, 100 kHz (*1)
- Up to 8 power channels optimizing your measurement: 8-channel power measurement
- Accurately measure high-frequency, low-power-factor power: Current sensor automatic phase correction function (*2)
- Simultaneous analysis of 4 motors: 4-motor/2-motor simultaneous analysis function
- Integration of measurement data into CAN networks: CAN or CAN FD output function
- Intuitive and Quantitative Insights with Power Spectrum Analysis (PSA) function
- Safe evaluation of increasingly high-voltage solar inverters: 1500 V DC CAT II / 1000 V DC CAT III (*3)
- Earning Japan Calibration Service System (JCSS) Certification for DC Power Measurement. (*4)
*1:When using the 15MS/S Input Unit U7005 *2:When used with a current sensor with automatic phase correction functionality *3:When using the 2.5MS/S Input Unit U7001 *4:JCSS is standard that is satisfy the requirements of the ISO/IEC 17025 international standard.
Videos
Specifications
Accuracy guaranteed for 6 months, multiply the 6-month accuracy reading error by 1.5 to obtain the 1-year accuracy.
| Measurement lines | 1-phase-2-wire, 1-phase-3-wire, 3-phase-3-wire, 3-phase-4-wire |
|---|---|
| No. of PW8001 input units | Max. 8 units (mix and match) |
| Type of input unit | U7001 2.5 MS/s INPUT UNIT U7005 15 MS/s INPUT UNIT |
| Measurement frequency band | U7001: DC, 0.1 Hz to 1 MHz U7005: DC, 0.1 Hz to 5 MHz |
| Sampling | U7001: 2.5 MHz, 16-bit U7005: 15 MHz, 18-bit |
| Data update rate | 1 ms, 10 ms, 50 ms, 200 ms |
| Accuracy for power (U7001) | 50/60 Hz: 0.02% of reading + 0.05% of range DC: 0.02% of reading + 0.05% of range 50 kHz : 0.4% of reading + 0.1% of range |
| Accuracy for power (U7005) | 50/60 Hz : 0.01% of reading + 0.02% of range DC : 0.02% + 0.03% of reading of range 50 kHz: 0.15% of reading + 0.05% of range |
| Measurement range | Voltage: 6 V, 15 V, 30 V, 60 V, 150 V, 300 V, 600 V, 1500 V Current: (Probe1) 40 mA to 2 kA, (Probe2) 100 mA to 50 kA (Probe1 : Hioki’s high-accuracy current sensor interface supports automatic identification and phase shift correction. Probe 2: BNC I/F only for U7001) |
| Measurement parameters | voltage (U), current (I), active power (P), apparent power (S), reactive power(Q), power factor (λ), phase angle (φ), voltage frequency(fU), current frequency(fI), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)
– Harmonics measurement : (Wideband mode: Maximum analysis order 500th, IEC measurement mode) |
| IEC measurement mode | When the measurement line has a frequency of 50 Hz or 60 Hz, the instrument can perform harmonic measurements according to IEC61000-4-7 and voltage fluctuation/flicker measurements according to IEC61000-4-15 |
| IEC-compliant harmonic measurement | Compliant with IEC 61000-4-7:2002
Analysis order: Harmonics: 0th to 200th orders, Inter-harmonic: 0.5th to 200.5th orders |
| IEC-compliant flicker measurement | Compliant with IEC 61000-4-15:2010 Ed 2.0 Flickermeter Class F2
Measurement items: Short-term flicker (Pst), Maximum short-term flicker value (PstMax), Long-term flicker value (Plt), |
| Calculation function | Efficiency and loss calculations, User-defined calculations, Delta conversion, Current sensor automatic phase shift calculation |
| Synchronization measurement | Optical link: Up to two units, 16 channels maximum BNC Synchronization: Up to four units, 32 channels maximum |
| External interface | USB flash drive, LAN, GP-IB, RS-232C, external control, optical link, BNC sync., CAN or CAN FD |
| Power supply | 100 V to 240 V AC, 50/60 Hz, 230 VA |
| Dimensions and mass | Approx. 430 mm (16.93 in) W × 221 mm (8.70 in) H × 361mm (14.21 in) D, Approx. 14kg (493.84 oz) |
| Included accessories | – Power cord ×1 – Instruction Manual ×1 – D-sub 25-pin connector ×1 (PW8001-02, -05, -12, -15 only) |