This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Exceptional support tool with multifaceted functionality designed to help analyze a variety of issues and boost work efficiency.
Supports wireless communication to increase work efficiency.
High voltage measurement up to CAT Ⅲ 2000 V by connecting a dedicated probe.
DC V typical accuracy: ±0.15% rdg. ±2 dgt.
Measurement categories: CAT III (1000 V), CAT IV (600 V)
Terminal shutter closes on unused terminals depending on the measurement function
Prevents incorrect current measurement with the Fuse Check function
Automatic switching of measurement in locations where AC and DC voltages are mixed
Test leads with an integrated cap for greater convenience and safety
Free up hands for work with the magnetic strap*1 and auto-hold function
Manage measurement data on a computer*2
*1 The Magnetic Strap is sold separately *2 Using the Communication Package DT4900-01 (sold separately)
Digital Multimeter
Model:
DT4261
Maker:
HIOKI E.E. CORPORATION
Features
- Helping personnel analyze issues in the field
- Boost work efficiency with digitalization (Excel® Direct Input Function)
- Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
- Stop worrying about losing test lead caps
- Excellent dust and water resistance (compliant with the IP54 international standard)
HIOKI DIGITAL MULTIMETER DT4261
Specifications
Accuracy guaranteed: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 Hz – 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
| DC + AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| LoZ V | 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt. |
| DC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy: ±0.5% rdg. ±3 dgt. |
| AC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy 40 Hz – 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less) Frequency characteristics: 40 Hz to 1 kHz |
| AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Continuity Check | Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more |
| Diode test | Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V |
| Voltage frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage) Basic accuracy: ±0.1% rdg. ±1 dgt. |
| Current frequency range | 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current) Basic accuracy: ±0.1% rdg. ±1 dgt. |
| Harmonic levels | [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. |
| Other functions | Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed) |
| Display | Main and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph |
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s) |
| Power supply | LR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications) |
| Dimensions and mass | 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries) |
| Included accessories | Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1 |




