CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

HIOKI Digital Multimeter DT4261

Exceptional support tool with multifaceted functionality designed to help analyze a variety of issues and boost work efficiency.

Supports wireless communication to increase work efficiency.
High voltage measurement up to CAT Ⅲ 2000 V by connecting a dedicated probe.
DC V typical accuracy: ±0.15% rdg. ±2 dgt.
Measurement categories: CAT III (1000 V), CAT IV (600 V)

Terminal shutter closes on unused terminals depending on the measurement function
Prevents incorrect current measurement with the Fuse Check function
Automatic switching of measurement in locations where AC and DC voltages are mixed
Test leads with an integrated cap for greater convenience and safety
Free up hands for work with the magnetic strap*1 and auto-hold function
Manage measurement data on a computer*2

*1 The Magnetic Strap is sold separately *2 Using the Communication Package DT4900-01 (sold separately)

Digital Multimeter

Model:

DT4261

Maker:

HIOKI E.E. CORPORATION

Features

  • Helping personnel analyze issues in the field
  • Boost work efficiency with digitalization (Excel® Direct Input Function)
  • Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
  • Stop worrying about losing test lead caps
  • Excellent dust and water resistance (compliant with the IP54 international standard)

HIOKI DIGITAL MULTIMETER DT4261

Specifications

Accuracy guaranteed: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.

DC Voltage range 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt.
AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 Hz – 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
DC + AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
LoZ V 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
Resistance range 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt.
DC Current range 600.0 mA to 10.00 A, 3 ranges
Basic accuracy: ±0.5% rdg. ±3 dgt.
AC Current range 600.0 mA to 10.00 A, 3 ranges
Basic accuracy 40 Hz – 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
Frequency characteristics: 40 Hz to 1 kHz
AC Current range (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges
Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance range 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt.
Continuity Check Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more
Diode test Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
Voltage frequency range 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Current frequency range 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Harmonic levels [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio

*Harmonics can be displayed with our free app GENNECT Cross.

Other functions Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
Display Main and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s)
Power supply LR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications)
Dimensions and mass 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries)
Included accessories Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.