CONTENTS CONTENTS

Products

The products listed here are for overseas markets, not for Japan domestic.

ANRITSU METER Micro Sensor Probes CS Series CS-11K-010-1-TC1-ANP

Measure the temperature of small stationary surface.

Model CS series probes are small surface temperature sensors designed to measure the temperature of stationary surface.Specific components may be combined to customize products for the needs of a customer's specific application.

Micro Sensor Probes CS Series

Model:

CS-11K-010-1-TC1-ANP

Maker:

ANRITSU METER CO., LTD.

Features

  • Head size:φ4.2mm
  • Pipe length:100mm
  • Temperature range:-50 to 400°C
  • Tolerance:±2.5°C(at 100°C surface)
  • Response time:2s
  • Durability :More than 50,000 contacts

Specifications

Model number*1 CS-0* CS-1*
CS-2*
CS-3*
CS-7*
Thermocouple type Type E or K
Temp. range*2 -50 to 400°C -50 to 600°C
Tolerance*3 -50°C ≦ t ≦ -40°C ±3.5°C ±2.5°C ±2.5°C
-40°C < t ≦ 100°C ±3.0°C ±2.5°C ±2.5°C
100°C < t ≦ 200°C ±5.0°C ±3.1°C ±3.1°C
200°C < t ≦ 300°C ±7.5°C ±5.0°C ±5.0°C
300°C < t ≦ 400°C ±10.0°C ±6.3°C ±6.3°C
400°C < t ≦ 500°C – – ±8.0°C
500°C < t ≦ 600°C – – ±13.0°C
Response time*4 3s 2s
Durability*5 A(More than 50,000 contacts)
Pipe material Stainless(SUS304)
Grip material Phenol Resin
Repair*6 Repairable

*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted.
*2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug.
*3 Tolerance is available at -50°C or above within the operating temperature on a stationary flat and smooth metal surface.
*4 The response time is the time required to detect 99% of the true value on a flat and smooth metal surface.
*5 Number of contacts enabling measurement within the tolerance range on a flat and smooth metal surface at a temperature of 300°C.
*6 Please refer to page repair.

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.