This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Suitable for measuring the temperature of moving or rotating surfaces.
The U series probes offer minimal coefficient of friction between the sensor and measuring surface, making them ideal for measuring the temperatures of moving or rotating surfaces.Specific components may be combined to customize products for the needs of a customer's specific application.
General Moving / Rotating Surface Probes U Series
Model:
U-211K-01-D0-0-TC1-W
Maker:
ANRITSU METER CO., LTD.
Features
- No grip type
- Head size:25×32×15mm
- Temperature range :-50 to 250°C
- Tolerance :±2.5°C (at 100°C surface)
- Response time :3.5s
- Durability :More than 1500 hours continuously
Specifications
| Model number*1 | Fluororesin guard | U-11* U-17* |
U-14* | U-21* U-27* |
U-24* |
| Bearing wheel | – | U-12* U-15* U-18* |
– | U-22* U-25* U-28* |
|
| Fluororesin wheel | U-13* U-19* |
U-16* | U-23* U-29* |
U-26* | |
| Thermocouple type | Type E or K | ||||
| Temp. range*2 | -50 to 250°C | -50 to 200°C | -50 to 250°C | -50 to 200°C | |
| Tolerance*3 | 0°C ≦ t ≦ 200°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C |
| 200°C < t ≦ 250°C | ±3.0°C | – | ±3.0°C | – | |
| Response time*4 | 2s | 3.5s | |||
| Durability*5 | More than 1500 hours continuously | ||||
| Pipe material | Stainless(SUS316) | ||||
| Grip material | Polyacetal | ||||
| Repair*6 | Repairable | ||||
*1 The asterisk (*) is replaced by the number of the model name you selected. The model number after thermocouple type is omitted.
*2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug.
*3 Tolerance is available at 0°C or above within the operating temperature on a stationary flat and smooth metal surface.
*4 The response time is the time required to detect 99% of the true value on a flat and smooth metal surface.
*5 Time period in which measurement was achieved within the accuracy range, on a flat and smooth metal surface moving at a rate of 200 m/min.
*6 Please refer to page repair.