This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Internal temperature sensors designed measure the temperatures of liquid semi-solid materials
Model BS series probes are internal temperature sensors designed to measure the temperatures of liquid or semi-solid materials. Specific components may be combined to customize products for the needs of a customer's specific application.
General Internal Probes Mode BS Series
Model:
BS-11K-010-TS1-ANP
Maker:
ANRITSU METER CO., LTD.
Features
- Probe diameter : φ1.5mm
- Pipe length : 100mm
- Tolerance : ±2.5℃ (at 100℃)
- Response time : 1.5sec
- Temperature range : -200~300℃
Specifications
BS-21 / BS-22 / BS-31 / BS-32 / BS-51
| Model number*1 | BS-21 | BS-22 | BS-31 | BS-32 | BS-51 | |
| Thermocouple ッtype | Type E or K | |||||
| Temp.range*2 | -200~500°C | -200~200°C | -200~500°C | -200~200°C | -200~500°C | |
| Tolerance*3 | 0°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C |
| 100°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | |
| 200°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | |
| 300°C | ±2.5°C | – | ±2.5°C | – | ±2.5°C | |
| 400°C | ±3.0°C | – | ±3.0°C | – | ±3.0°C | |
| 500°C | ±3.8°C | – | ±3.8°C | – | ±3.8°C | |
| Tolerance calculation method t:Temperature(°C) |
At within temperature range |
|||||
| Response time*4 | 2.5s | 20s | 3s | 20s | 5s | |
| Durability*5 | B(More than 1 year) | |||||
| Pipe Diameter | φ2.1mm | φ2.5mm | φ3.0mm | φ3.4mm | φ5.0mm | |
| Pipe material | Stainless(SUS304) | |||||
| Grip material | Nylon Resin | |||||
| Repair*6 | Non-repairable | |||||
BS-91 / BS-92 / BS-11 / BS-12
| Model number*1 | BS-91 | BS-92 | BS-11 | BS-12 | ||
| Thermocouple Type | Type E or K | |||||
| Temp.range*2 | -200~300°C | -200~200°C | -200~300°C | -200~200°C | ||
| Tolerance*3 | 0°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | |
| 100°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ||
| 200°C | ±2.5°C | ±2.5°C | ±2.5°C | ±2.5°C | ||
| 300°C | ±2.5°C | – | ±2.5°C | – | ||
| Tolerance calculation method t:Temperature(°C) |
At within temperature range |
|||||
| Response time*4 | 0.5s | 20s | 1.5s | 20s | ||
| Durability*5 | C(More than 6 month) | |||||
| Pipe Diameter | φ0.9mm | φ1.3mm | φ1.5mm | φ1.9mm | ||
| Pipe material | Stainless(SUS304) | |||||
| Sleeve materials | Stainless(SUS316) | |||||
| Repair*6 | Non-repairable | |||||
*1 The model number after thermocouple type is omitted.
*2 The operating temperature limit is determined by the allowable temperature limit of the sensor head contacts the measurement target. Note that the operatingtemperature limit is not the same as the allowable temperature limits of the grip, cable, and plug.
*3 Tolerance is defined in the operating temperature range of -196°C or higher at the internal temperature with sufficient heat capacity. For tolerance at temperature not listed in the above table, please refer to calculation method of tolerance.
*4 The response time given for our temperature measuring probes is the time required to detect 99% of the true value when measuring the temperature of boiling water or vapor.
*5 When used correctly, virtually no deterioration occurs in these products due to temperature measuring operations. Therefore, the durability is based on the ease with which impact results in damage. The durability is defined as 1 year or more in little or no degradation of quality.
*6 Please refer to page repair.