This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
Capable of measurements in environments subject to high-frequency waves or high voltages.
FL Series can measure temperatures in environments subject to high-frequency waves, microwaves, or high voltages-areas where electric thermometers such as thermocouples, platinum resistance temperature detectors, and thermistors are typically ineffective.
Capable of measurements in environments subject to high-frequency waves or high voltages.
A fiber optic thermometer offering a wide measurement range.
Analog output capability allows use for machine temperature control.
Measurement data can be imported into a PC using software* bundles with the thermometer.
* for Microsoft® Windows® 7, Windows® 8.1, Windows® 10, Windows® 11 (for English)
Fiber Probes FL Series
Model:
FL-2400
Maker:
ANRITSU METER CO., LTD.
Features
- Up to 4ch measurements
- High accuracy (±0.5℃ with calibration)
- Wide measurement range. (-195~400℃)
- With analog output (10mV/℃)
- Measurement data can be imported into a PC by software.
Specifications
| Model | FL-2000 | FL-2400 | |
|---|---|---|---|
| Channel | 1 | 4 | |
| Measurement Range | -195.0 to 450.0°C | ||
| Resolution | 0.1°C | ||
| Accuracy | Calibration not executed | -195.0 to 399.9°C:±2°C 400.0 to 450.0°C:±5°C | |
| Calibration executed |
±0.5°C (within ±50°C of caribration point) |
||
| Temperature coefficient | ±(0.01% of F.S./°C) Outside 25℃±5℃ | ||
| Operating environment |
Temperature : 0 ~ 40°C Humidity : 15 ~ 80%RH(non-condensing) |
||
| Storage environment |
Temperature : -10 ~ 50°C Humidity : 10 ~ 85%RH(non-condensing) |
||
| Display | Height of character : 15mm | Height of character : 8mm RED | |
| Display update | 1sec | ||
| Light source | Blue LED | ||
| Power supply | Please specify a supply voltage when ordering(choose from 100VAC, 115VAV, or 230VAC) six AA-size alkaline batteries |
Please specify a supply voltage when ordering(choose from 100VAC, 115VAV, or 230VAC) | |
| Power consumption | approx. 12 VA | approx. 40 VA | |
| Memory capacity |
UP to 15,000 data, one second interval (synchronized with display) |
No memory | |
| Interface |
RS-232C Transfer rate : 9600bps Data formation : 7bit, odd parity, 1 stop bit |
||
| Calibration |
One-point calibration (using real temperature within a measured area) |
||
| Analog output | Output rate | 10mV/°C | |
| Resolution | 1mV | ||
| Accuracy | ±(0.2% of F.S) at an ambient temperature of 25°C±5°C | ||
| Temperature coefficient | ±(0.01% of F.S./°C) | ||
| Dimensions |
210(W)×88(H)×230(D) mm Protruded parts excluded |
320(W)×99(H)×280(D) mm Protruded parts excluded |
|
| Weight | approx. 3kg | approx. 5kg | |
| Supplied accessories |
Power cable(two-wire plug attached)×1 Fuse(2A mini fuse)×1 Analog output cable×1 communication cable×1 PC software AMS-850 (CD ROM)×1 User’s manual(main unit and software)×1 |
Power cable(two-wire plug attached)×1 Fuse(2A mini fuse)×1 Analog output cable×4 Communication cable×1 Conversion cable (RS-232C→USB)×1 PC software AMS-850 (CD ROM)×1 User’s manual(main unit and software)×1 |
|