This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Products
The products listed here are for overseas markets, not for Japan domestic.
The sheathed section can be bent to a radius five times the outer diameter of the sheath.
Model SHEATH series probes are internal temperature sensors designed to measure the temperature of liquids, air, and gases. The sheathed section can be bent to a radius five times the outer diameter of the sheath. Specific components may be combined to customize products for the needs of a customer's specific application.
Bendable wiry probes Model SHEATH series
Model:
B0.5-K-J1-M3-L100-TS1-ANP
Maker:
ANRITSU METER CO., LTD.
Features
- Sleeve type (SUS304, φ5mm)
- Sheath diameter : φ0.5mm
- Junction type : Grounded junction (J1)
- Sheath material : Inconel (M3)
- Sheath length : 100mm
Specifications
Tolerance
| Thermocouple type | Temp. range | Class | Tolerance |
| Type E | 333°C ≦ t < 900°C | Class2 | ±0.0075・|t|°C |
| -40°C ≦ t < 333°C | ±2.5°C | ||
|
Type K |
333°C ≦ t < 1200°C | ±0.0075・|t|°C | |
| -40°C ≦ t < 333°C | ±2.5°C |
Response time and Standard resistance
| Outside diameter(mm) | Response time(s) | Standard resistance(Ω/m) | |
| Type E | Type K | ||
| 0.25 | 0.4 | – | 570 |
| 0.5 | 0.9 | – | 124 |
| 1.0 | 2 | 38 | 32 |
| 1.6 | 3 | 15 | 13 |
| 3.2 | 5 | 5 | 4 |
| 4.8 | 10 | 2.6 | 2.2 |
| 6.4 | 15 | 1.2 | 1.0 |
| 8.0 | 20 | 0.9 | 0.7 |
*Avoid immersing these probes in molten aluminum. Doing so may result in corrosion of the sheathed sensor.
*Make sure that the sum of the sheath and code resistance values does not exceed the value of the signal source resistance of the instrument body.
Max. Temp.(°C)
| Thermocouple type | Type E | Type K | |||
| Material | SUS316 | SUS316 | SUS310S | Inconel | |
|
Diameter (mm) |
0.25 | – | – | – | 500 |
| 0.5 | – | – | – | 500 | |
| 1.0 | 650 | 650 | 650 | 650 | |
| 1.6 | 650 | 650 | 650 | 650 | |
| 3.2 | 750 | 750 | 750 | 750 | |
| 4.8 | 800 | 800 | 800 | 900 | |
| 6.4 | 800 | 800 | 800 | 1000 | |
| 8.0 | 800 | 900 | 900 | 1050 | |
*Operating temperature limit 200°C with Fluororesin coating.