The PXZ Series offers a 20kW power capacity with a maximum voltage of 1500V, housed in a 3U unit. It supports CC, CR, CV, and CP modes and can link up to 25 units to achieve 500kW in parallel. Equipped with a touch panel, it includes pre-charge, I-V, sequence functions, and versatile connectivity options like LAN, USB, and RS232C.

High-Capacity Regenerative Electronic Load

Model:

PXZ Series

Maker:

KIKUSUI

Download Materials

Line-up

Specifications

Ratings

Item PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Rated power 20000W 20000W 20000W
Rated voltage (DC)*1 10 V to 500 V 20 V to 1000 V 30 V to 1500 V
Rated current *1 120A 60A 30A

*1 Maximum input current and maximum input voltage are limited by maximum input power.
 

Constant Current (CC) mode

Item PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Maximum settable current *1 +126 A +63A +31.5 A
Setting accuracy*2 ±(0.75 % of rating) ±(0.75 % of rating) ±(0.75 % of rating)
Resolution 0.01 A 0.005A 0.002 A
Line regulation *3 ±240 mA ±120mA ±60 mA
Load regulation *4 ±240 mA ±120mA ±60 mA
Rise time(TYP)*5 1 ms 1 ms 1 ms
Fall time (TYP)*6 1 ms 1 ms 1 ms
Response switching FAST, SLOW FAST, SLOW FAST, SLOW
Slew rate switching *1 120A/ms or more *7 60A/ms or more *7 30A/ms or more *7
60 A/ms 30 A/ms 15 A/ms
30 A/ms 15.0A/ms 7.5 A/ms
3 A/ms 1.50A/ms 0.75 A/ms
0.3 A/ms 0.150A/ms 0.075 A/ms

*1. During parallel operation, this will be the value multiplied by the number of units in the configuration. *2. Applies to a range of 1 % to 100 % of the rated current. *3. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load. *4. This is the amount of change when the voltage is changed from the rated voltage and rated power to 1/10 of the rated voltage. *5. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 10 % to 90 % of the rated current when the input current
value is changed from 0 % to 100 % of the rated current. When the slew rate is set to MAX. *6. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 90 % to 10 % of the rated current when the input current
value is changed from 100 % to 0 % of the rated current. When the slew rate is set to MAX. *7. MAX will appear on the display.

 

Constant resistance (CR) mode

Item PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Conductance rating 2400.0 mS 600.000mS 200.000 mS
Setting range 0 mS to 2520.0 mS 0mS to 630.000mS 0 ms to 210.000 mS
Setting accuracy *1 ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating)
Resolution 0.20 mS 0.05mS 0.02 mS
Response switching FAST, SLOW FAST, SLOW FAST, SLOW

*1 Converted value at the input current.
 

Constant voltage (CV) mode

Item PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Maximum settable voltage *1 525 V 1050V 1575 V
Setting accuracy ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating)
Resolution 0.05 V 0.1 V 0.1 V
Remote sensing Maximum compensation voltage (reciprocating) (TYP) 10 % of rating 10 % of rating 10 % of rating
Response switching FAST, SLOW FAST, SLOW FAST, SLOW
Slew rate switching (TYP) *1 125V/ms or more *2 250V/ms or more *2 375V/ms or more *2
125V/ms 250V/ms 375V/ms
12.5 V/ms 25 V/ms 37.5 V/ms
1.25 V/ms 2.50 V/ms 3.75 V/ms
0.125 V/ms 0.25 V/ms 0.375 V/ms

*1 During parallel operation, this will be the value multiplied by the number of units in the configuration. *2 MAX will appear on the display.
 

And More

Constant Power (CP) mode

200 V three-phase three-wire input

400 V three-phase three-wire input

Protection specifications LOW alarm

Protection Specifications HIGH alarm

General specifications