This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Compact Wide-Range DC Power Supplies
Sale Price : $1,380+Delivery Fee
Lead Time : In Stock*
Key Features
- Sequence function (supports triggered synchronization)
- Variable internal resistance function
- LAN (LXI compliant) /USB/RS232C as standard interface
- A virtual multi-channel bus (VMCB) function makes multi-channel operation more efficient
- A wide range of voltage and current settings can be combined within its output power rating (3 to 4 times)
- Supporting universal input voltage (up to 240 V)
- CONFIG setting shortcut function and display (Up to three parameters can be registered.)
- Setting preset memory function (3 combinations of settings for voltage, current, OVP, OCP, and UVL)
- Bleeder (sink) can be turned ON/OFF, with an even stronger bleeder mode setting available
- Output ON/OFF delay function
- Soft start/stop function
- Durable Performance Operating temperature guaranteed up to 50 °C (122 °F). (Storage temperature is -25 °C to +60 °C (-13 °F to 140 °F).)
Specifications
AC Input
| Item/Model | PWR401MH | |
| Nominal input rating | 100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase | |
| Input voltage range | 85 Vac to 265 Vac | |
| Input frequency range | 47 Hz to 63 Hz | |
| Current (TYP) *1 | 100 Vac | 5.6 A |
| 200 Vac | 2.8 A | |
| Inrush current | 25 Apeak or less | |
| Power (MAX) *2 | 560 VA | |
| Power factor (TYP) *1 | 0.99 (input voltage: 100 V), 0.97 (input voltage: 200 V) | |
| Efficiency (TYP) *1 | 75% | |
| Output hold time *2 | 20 ms or more | |
| *1. At the rated output power for the rated output current. *2. 100 Vac, at the rated output power. | ||
Output
| Item/Model | PWR401MH | ||
| Rating | Output voltage*1 | 240 V | |
| Output current*1 | 5A | ||
| Output power | 400 W | ||
| Voltage | Maximum settable voltage*2 | 252 V | |
| Accuracy | ±(0.05 % of setting +0.05 % of rating) | ||
| Resolution | 1000 mV | ||
| Using FINE, OUT OFF | 100 mV | ||
| Using FINE, OUT ON | 10 mV | ||
| When using a communication interface | 0.1 mV | ||
| Line regulation *3 | ±26 mV | ||
| Load regulation *4 | ±26 mV | ||
| Transient response *5 | 2 ms or less | ||
| Ripple noise *6 | p-p *7 | 100 mV | |
| rms *8 | 20 mV | ||
| Rise time | At full load | 100 ms or less | |
| No load | 100 ms or less | ||
| Fall time *9 | At full load | 150 ms | |
| No load | 1200 ms | ||
| Maximum remote sensing compen- sation voltage (single line) | 5 V | ||
| Temperature coefficient *10 | 100 ppm/℃ | ||
| Current | Maximum settable current *2 | 5.25 A | |
| Setting accuracy *11 | ±(0.5 % of setting +0.1 % of rating) | ||
| Resolution | 20 mA | ||
| Using FINE, OUT OFF | 1 mA | ||
| Using FINE, OUT ON | 0.1 mA | ||
| When using a communication interface | 0.1 mA | ||
| Power fluctuation | ± 2.5 mA | ||
| Load variation | ± 6.0 mA | ||
| Ripple noise *12 | rms*8 | 12 mA | |
| Rise time (TYP) | At full load | 100 ms | |
| Fall time (TYP) | At full load | 100 ms | |
| Temperature coefficient *10 | 100 ppm/℃ | ||
| Maximum internal resistance that can be set | 36.00 Ω | ||
| *1. The maximum output voltage and maximum output current are limited by the maximum output power. *2. Can be limited to approximately 95 % of the OVP trip point or OCP trip point. *3. 85 Vac to 135 Vac or 170 Vac to 265 Vac, fixed load *4. The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point. *5. The amount of time required for the output voltage to return to a value within “rated output voltage ± (0.1 % +10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage. *6. Measured using an RC-9131C probe that conforms to the JEITA specifications. At the rated output current. *7. When the measurement frequency bandwidth is 10 Hz to 20 MHz. *8. When the measurement frequency bandwidth is 10 Hz to 1 MHz. *9. When the bleeder circuit is set to bleeder normal. *10. When the ambient temperature is within 0°C and 50 °C *11. Applies to the range of 1 % to 100 % of the rated current. TYP (0.1 % of rating) for 0 % to 1 %. *12. When the output voltage is 10 % to 100 % of the rating. At the rated output current. | |||
Display
| Item/Model | PWR401MH | |
| Voltage display | Maximum display | 999.9 |
| Display accuracy | ± (0.2 % of reading +5 digits) | |
| Current display | Maximum display | 9.999 |
| Display accuracy | ± (0.5 % of reading +8 digits) | |
| Power display | ||
| Maximum display | 9999 | |
| Display accuracy | Displays the result of multiplying the current and voltage. The display is toggled with the voltage or current display. | |