KIKUSUI PWR1201ML

Compact Wide-Range DC Power Supplies

 

Claim Limited-Time Discount



Sale Price : $2,140+Delivery Fee
Lead Time : In Stock*

DC Power Supply

Model:

PWR1201ML

Maker:

KIKUSUI

Download Materials

Key Features

  • Sequence function (supports triggered synchronization)
  • Variable internal resistance function
  • LAN (LXI compliant) /USB/RS232C as standard interface
  • A virtual multi-channel bus (VMCB) function makes multi-channel operation more efficient
  • A wide range of voltage and current settings can be combined within its output power rating (3 to 4 times)
  • Supporting universal input voltage (85 V to 265 V)
  • CONFIG setting shortcut function and display (Up to three parameters can be registered.)
  • Setting preset memory function (3 combinations of settings for voltage, current, OVP, OCP, and UVL)
  • Bleeder (sink) can be turned ON/OFF, with an even stronger bleeder mode setting available
  • Output ON/OFF delay function
  • Soft start/stop function
  • Durable Performance Operating temperature guaranteed up to 50 °C (122 °F). (Storage temperature is -25 °C to +60 °C (-13 °F to 140 °F).)

Specifications

AC Input

Item/Model PWR1201ML
Nominal input rating 100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase
Input voltage range 85 Vac to 265 Vac
Input frequency range 47 Hz to 63 Hz
Current (TYP) *1 100 Vac 16.8 A
200 Vac 8.4 A
Inrush current 75 A or less
Power (MAX) *2 1680 VA
Power factor (TYP) *1 0.99 (input voltage: 100 V), 0.97 (input voltage: 200 V)
Efficiency (TYP) *1 75%
Output hold time *2 20 ms or more
*1. At the rated output power for the rated output current. *2. 100 Vac, at the rated output power.

 

Output

Item/Model PWR1201ML
Rating Output voltage *1 80 V
Output current *1 60 A
Output power 1200 W
Voltage Maximum settable voltage *2 84 V
Accuracy ±(0.05 % of setting +0.05 % of rating)
Resolution 400 mV
Using FINE, OUT OFF 10 mV
Using FINE, OUT ON 1 mV
When using a communication interface 0.1 mV
Line regulation *3 ± 10 mV
Load regulation *4 ± 10 mV
Transient response *5 2 ms or less
Ripple noise *6 p-p *7 50 mV
rms *8 5 mV
Rise time At full load
No load
Fall time *9 At full load
No load
Maximum remote sensing compen- sation voltage (single line) 4 V
Temperature coefficient *10 100 ppm/ ℃
Current Maximum settable current *2 63 A
Setting accuracy *11
Resolution 300 mA
Using FINE, OUT OFF 10 mA
Using FINE, OUT ON 1 mA
When using a communication interface 0.1 mA
Power fluctuation ± 8 mA
Load variation ± 17 mA
Ripple noise *12 rms *8 120 mA
Rise time (TYP) At full load 50 ms
Fall time (TYP) At full load 50 ms
Temperature coefficient *10 100 ppm/ ℃
Maximum internal resistance that can be set 1.333 Ω
*1 The maximum output voltage and maximum output current are limited by the maximum output power. *2 Can be limited to approximately 95 % of the OVP trip point or OCP trip point. *3 85 Vac to 135 Vac or 170 Vac to 265 Vac, fixed load. *4 The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point. *5 The amount of time required for the output voltage to return to a value within “rated output voltage ± (0.1 % +10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage. *6 Measured using an RC-9131C probe that conforms to the JEITA specifications. At the rated output current. *7 When the measurement frequency bandwidth is 10 Hz to 20 MHz. *8 When the measurement frequency bandwidth is 10 Hz to 1 MHz. *9 When the bleeder circuit is set to bleeder normal. *10 When the ambient temperature is within 0°C and 50 °C. *11 Applies to the range of 1 % to 100 % of the rated current. TYP (0.1 % of rating) for 0 % to 1 %. *12 When the output voltage is 10 % to 100 % of the rating. At the rated output current.