This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Intelligent Bipolar Power Supply
Sale Price : $7,400+Delivery Fee
Lead Time : In Stock*
・Waveform generation function
・Sequence function
・Synchronized operation function(Trigger-based, Clock-based)
・Parallel operation function (Applied to the same model for 2 units in parallel connection)
・Unipolar mode
・High-speed response
・Low ripple noise(CV mode)
Specifications
AC input, rated output
| Item/Model | PBZ80-5 | ||
| AC input | Nominal input voltage | 100 Vac to 240 Vac, 50 Hz to 60 Hz | |
| Voltage and frequency range | 90 Vac to 250 Vac, 47 Hz to 63 Hz | ||
| Current | 10 Aac or less (when connected to a rated load) | ||
| Inrush current (peak value) | 40 Apeak or less | ||
| Power | 900 VA or less (when connected to a rated load) | ||
| Apparent power | 0.95 TYP (when the input voltage is 100 V and when connected to a rated load) | ||
| Rated output | Output power | 400 W | |
| Output voltage | ±80 V | ||
| Output current | ±5 A | ||
| Peak current *2 | – | ||
| Isolation voltage | 500 Vdc, Only the output’s COM terminal can be grounded. | ||
| *1 1 ms or more *2 Set the peak current output time to 10 ms or more, the repetition interval to 1 s or mode, and the CV or CC mode current response to 1 ms. *3 (-17 V < Output terminal voltage < +17 V) *4 (-20 V ≤ Output terminal voltage ≤ +20 V) | |||
Constant voltage (CV mode)
| Item/Model | PBZ80-5 | ||
| DC voltage | Setting range*1 | Bipolar mode | 0.000 V to ±84.000 V |
| Unipolar mode | 0.000 V to 84.000 V | ||
| Fine feature | ±5 % of rating | ||
| Setting resolution | 0.002 V (0.0002 V for the fine feature) | ||
| Setting accuracy*2 | ±(0.05 % of setting + 0.05 % of rating) | ||
| Temperature coefficient | ±100 ppm/°C of rtg (TYP) | ||
| AC voltage | Setting range*1 | 0.00 Vpp to 168.00 Vpp | |
| Setting resolution | 0.1 V | ||
| Accuracy of setting*3 | ±0.5 % of rating | ||
| AC frequency | Selectable range | 0.01 Hz to 200.00 kHz | |
| Setting resolution | 0.01 Hz | ||
| Setting accuracy | ±200 ppm | ||
| Sweep | Linear and logarithmic | ||
| Sweep time | 100 μs to 1000 s (resolution of 100 μs) | ||
| AC waveform | Type | Sine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms | |
| Start phase | 0 ° to 359 ° | ||
| Square wave duty cycle | 0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f) | ||
| Constant voltage characteristics | Frequency response *4 | DC to 100 kHz (TYP) | |
| Response *5, *6 | 3.5 μs, 10 μs, 35 μs, 100 μs (TYP) | ||
| Overshoot | 5 % or less (TYP) | ||
| Ripple noise | (p-p)*7 | 30 mV (TYP) | |
| (rms)*8 | 4 mV (TYP) | ||
| Load effect *8 | ±(0.005 % of setting + 1 mV) | ||
| Source effect *9 | ±(0.005 % of setting + 1 mV) | ||
| * 1. The peak value of the sum of the DC voltage and AC voltage is limited by the DC voltage’s settable range. * 2. At an ambient temperature between 18 °C and 28 °C. * 3. At an ambient temperature between 18 °C and 28 °C, with a 1 kHz sine wave, 3.5 μs response, and no load. * 4. A frequency where the amplitude ratio of the output voltage to the external signal input voltage is -3 dB (when the reference frequency is 1 kHz, the response is 3.5 μs, and when a rated load is connected). * 5. The rise or fall time (at rated load; excluding when output is turned on and off). The frequency response is based on the specified response setting (frequency bandwidth = 0.35/the rise time). * 6. Rise time: The time it takes for the output voltage to rise from 10 % to 90 % of the rating when the output voltage is changed from 0 V to the rated voltage. Fall time: The time it takes for the output voltage to fall from 90 % to 10 % of the rating when the output voltage is changed from the rated voltage to 0 V. * 7. The measurement frequency bandwidth is 10 Hz to 20 MHz (at the output terminals). * 8. The measurement frequency bandwidth is 10 Hz to 1 MHz (at the output terminals). * 9. The change in the output voltage in response to a change in the output current from 0 % to 100 % of the current rating (measured at the sensing terminals when remote sensing is used). * 10.The change in the output voltage in response to a ±10 % change in the input voltage in reference to the nominal input voltage (measured at the sensing terminals when remote sensing is used). | |||
Constant current (CC mode)
| Item/Model | PBZ80-5 | ||
| DC current | Setting range*1 | Bipolar mode | 0.000 A to ±5.250 A |
| Unipolar mode | |||
| Fine feature | ±5 % of rating | ||
| Setting resolution | 0.001 A (0.0001 A for the fine feature) | ||
| Setting accuracy*2 | ±0.3 % of rating | ||
| Temperature coefficient | ±100 ppm/°C of rating (TYP) | ||
| AC current | Setting range*1 | 0.00 App to 10.50 App | |
| Setting resolution | 0.01 A | ||
| Accuracy of setting*3 | ±0.5 % of rating | ||
| AC frequency | Selectable range | 0.01 Hz to 100.00 kHz | |
| Setting resolution | 0.01 Hz | ||
| Setting accuracy | ±200 ppm | ||
| Sweep | Linear and logarithmic | ||
| Sweep time | 100 μs to 1000 s (resolution of 100 μs) | ||
| AC waveform | Type | Sine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms | |
| Start phase | 0 ° to 359 ° | ||
| Square wave duty cycle | 0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f) | ||
| Constant current characteristics | Frequency response *4 | DC to 10 kHz (TYP) | |
| Response *5, *6 | 35 μs, 100 μs, 350 μs, 1 ms (TYP) | ||
| Overshoot | 5 % or less (TYP) | ||
| Ripple noise (rms) *7 | 3 mA (TYP) | ||
| Load effect *8 | ±( 0.01 % of setting + 1 mA ) | ||
| Source effect *9 | ±( 0.01 % of setting + 1 mA ) | ||
| * 1. The peak value of the sum of the DC current and AC current is limited by the DC current’s settable range. * 2. At an ambient temperature between 18 °C and 28 °C. * 3. At an ambient temperature between 18 °C and 28 °C, with a 100 Hz sine wave, 35 μs response, and shorted output. *4. A frequency where the amplitude ratio of the output current to the external signal input voltage is -3 dB (when the reference frequency is 100 Hz, the response is 35 μs, and a rated load is connected). The frequency response changes according to the load impedance. When the load impedance increases, the frequency response decreases. *5. The rise or fall time (at rated load; excluding when output is turned on and off). The rise and fall times change according to the load impedance. *6. Rise time:The time it takes for the output current to rise from 10 % to 90 % of the rating when the output current is changed from 0 A to the rated current. Fall time:The time it takes for the output current to fall from 90 % to 10 % of the rating when the output current is changed from the rated current to 0 A. * 7. The measurement frequency bandwidth is 10 Hz to 1 MHz (when the output voltage is in the range of 10 % to 100 % of the rated output voltage). * 8. The change in the output current in response to a change in the output voltage from 10 % to 100 % of the voltage rating. * 9. The change in the output current in response to a ±10% change in the input voltage in reference to the nominal input voltage (when the output voltage is in the range of 10 % to 100 % of the voltage rating ). | |||
Measurement display function
| Item/Model | PBZ80-5 | ||
| Voltage measurement | DC | Measurement range (resolution) | 120 % of rating(0.001 V) |
| Accuracy *1 | ±(0.05 % of reading+0.05 % of rating) | ||
| Temperature coefficient | ±(100 ppm/℃ of rating)(TYP) | ||
| AC | Measurement range (resolution) | 120 % of rating/CF(0.001 V) | |
| DC+AC | Measurement range (resolution) | 120 % of rating(0.001 V) | |
| AC and DC+AC | Accuracy*1*2 | ±(0.5 % of reading + 0.1 % of rating) in the range of 5 Hz to 10 kHz | |
| ±(1 % of reading + 0.2 % of rating) in the range of 10 kHz to 50 kHz | |||
| ±(2 % of reading + 0.2 % of rating) in the range of 50 kHz to 100 kHz | |||
| PEAK | Measurement range (resolution) | 120 % of rating(0.01 V) | |
| PEAK | Accuracy *1*3 | ±(0.5 % of rating) | |
| Current measurement | DC | Measurement range (resolution) | 120 % of rating(0.001 A) |
| Accuracy *1 | ±(0.3 % of reading + 0.1 % of rating) | ||
| Temperature coefficient | ±150 ppm/°C of rating (TYP) | ||
| AC | Measurement range (resolution) | 120 % of rating/CF (0.001 A) | |
| DC+AC | Measurement range (resolution) | 120 % of rating (0.001 A) | |
| AC and DC+AC | Accuracy*1*2 | ±(3 % of reading + 0.1 % of rating) in the range of 5 Hz to 10 kHz | |
| ±(10 % of reading + 1 % of rating) in the range of 10 kHz to 100 kHz | |||
| PEAK | Measurement range (resolution) | ±120 % of rating (0.01 A) | |
| PEAK | Accuracy *1*3 | ±0.5 % of rating | |
| Measurement time | 100 μs to 3600 s | ||
| * 1. At ambient temperature of 18 °C to 28 °C * 2. When the input signal is a sine wave with a crest factor of 3 or less within the prescribed frequency range and the measurement time is the no more than 10 times the period of the input signal * 3. Peak value of a 1 kHz sine wave |
Protection functions
| Item/Model | PBZ80-5 | |
| Overvoltage protection | Protection operation *1, *2 | OVP or V-LIMIT (output limit). Select whether output or the POWER switch turns off when OVP is activated. |
| Setting range (Bipolar mode) | Select whether (-110 % of rating ≤ -V.LIM ≤ +V.LIM ≤ +110 % of rating) or (-110 % of rating ≤ -OVP ≤ -1% of rating, +1 % of rating ≤ +OVP ≤ +110 % of rating) | |
| Setting range (Unipolar mode) | Select whether (-1 % of rating ≤ -V.LIM ≤ +V.LIM ≤ +110 % of rating) or (+ 1% of rating ≤ +OVP ≤ +110 % of rating) | |
| Setting resolution | 0.01 V | |
| Setting accuracy | ±1 % of rating | |
| Overcurrent protection *3 | Protection operation *1, *2 | OCP or I-LIMIT (output limit). Select whether output or the POWER switch turns off when OCP is activated. |
| Selectable range | Select wheter (-110 % of rating ≤ -I.LIM ≤ -1% of rating, +1 % of rating ≤ +I.LIM ≤ +110 % of rating) or (-110 % of rating ≤ -OCP ≤ -1 % of rating, +1 % of rating ≤ +OCP ≤ +110 % of rating) | |
| Setting resolution | 0.01 A | |
| Setting accuracy | ±1 % of rating | |
| Overheat protection | Protective operation | Turns output off when overheating is detected. |
| Overheat protection Power limit (sink power) | Bipolar mode | 200 W (TYP) |
| Unipolar mode | 400 W (TYP) | |
| * 1. Voltage is detected at the output terminals. * 2. OVP is activated even when V-LIMIT (voltage limit) is selected. The OVP activation point is approximately ±120 % of rtg. * 3. Peak current at 120 Apeak can be output for 10 ms with the CC mode response set to 1 ms. For other CC mode response settings, the peak current is limited (I.LIM) according to the specified response. | ||