global
Send us a message
product

ITEMLIST

Products Infomation

KIKUSUI Charge/Discharge System Controller PFX2500 Series

Energy Storage Essential to New Energy Application. Fully support Charge and Discharge Measurement from Basic Test to Simulation Test

[Contact Us]
 

The PFX2512/2532 Series provides advanced charge/discharge control for battery testing, offering precise measurement with 100 μV and 100 μA resolution. It allows seamless integration with DC power supplies and electronic loads, ensuring flexibility and cost efficiency. Equipped with digital CC/CV control, it minimizes disparities, enhancing accuracy without needing adjustments. Additionally, it features robust protection and easy data management for reliable evaluations.

Charge/Discharge System Controller

Model:

PFX2500 Series

Maker:

KIKUSUI

Download Materials

Features

Energy Storage Essential to New Energy Application.

-Fully support Charge and Discharge Measurement from Basic Test to Simulation Test-
PFX2512/2532 Series is a high performance Charge/Discharge system controller that takes measurements in combination with our DC power supply and electronic load in order to evaluate test sample (electric storage elements such as secondary batteries) characteristics. It is also capable to perform evaluation test with high-performance, large capacity and wide range of rating with the combination of DC power supply and electronic load. Execution of the test is conducted by the exclusive application software. The test corresponds to long time continuous test and synchronization test with temperature chambers with the multiplexed protection performance. In addition, easy data editing is also capable with fulfilling graphic performance.

 

Complicated Systems Integrated into One

PFX2512/2532 Series has integrated systems into one unit where battery evaluation is required. In addition, the series has high degrees of flexibility corresponding to wide range of rating since it is possible to combine our conventional DC power supply (for charging) and our electronic load (for discharging) tailored to needs. Introduction cost is able to be reduced by selecting equipment which meets charge/discharge test condition required.

 

Corresponding to Specification Test Pattern by Realizing Seamless Charge/Discharge

A certain time was required for transferring power supply and electronic load in the past. Seamless charge/discharge transfer has been realized at PFX2512/2532 by the simultaneous control of power supply and electronic load. For this reason, correspondence to characteristic test of recapturing complex applications such as application where charge/discharge repeating without taking breath is performed for electric motorcycle and electric assisted bicycle as well as electric vehicle and hybrid vehicle, and application for UPS for peak shift and to specification test pattern where continuous charge/discharge is performed such as IEC62660 became possible.

 

Easy Configuration

It is possible to configure the system by yourself. The DC power supply and electronic load that are applied configuration with PFX2512/2532, can be used for the system. This allows you to have a test system at low cost.

Control of the Constant Current (CC) and Constant Voltage (CV)

The adoption of the digital CC/CV control method minimizes the disparities in the constant current(CC)/ constant voltage(CV) setting accuracy and drift characteristics due to the differences in the system component devices(DC power supplies and electronic loads). This ensures highly accurate tests. There is absolutely no need to make adjustments after system configuration.

2 values CC pattern charge/discharge
Step 1 CHG: 200 A 500 ms
Step 2 DISCH: –200 A 500 ms

 

Highly accurate measurement

Highly accurate measurement circuits are built in. Battery voltage and charge/discharge current are detected with high accuracy. (Voltage measurement: 100 μV resolution, current measurement: 100 μA resolution, elapsed time measurement: monthly error of 30 s or less (10 ppm or less)) True electric energy and integrated capacity can be measured even for pulse currents that are difficult to be captured.

System Configuration

Specifications

Rated output
 

  PFX2512 PFX2532
Number of outputs 1 ch 1 ch
Charging current range *1 0.000 A to 50.000 A 0.000 A to 200.000 A
Charging voltage range *1 60 V range 0.000 V to 60.000 V 0.000 V to 60.000 V
6 V range 0.000 V to 6.000 V 0.000 V to 6.000 V
Discharge current range *1 0.000 A to 50.000 A 0.000 A to 200.000 A
Discharge voltage range*1, *2 60 V range 0.000 V to 60.000 V 0.000 V to 60.000 V
6 V range 0.000 V to 6.000 V 0.000 V to 6.000 V

 
Measurement accuracy
 

  PFX2512 PFX2532
Static
Charge/ discharge
Current measurement
Range 0.0000 A to 50.0000 A 0.000 A to 200.000 A
Accuracy *3 ± (0.15 % of reading + 0.02 % of rating) ± (0.2 % of reading + 0.1 % of rating)
Resolution 0.1mA 1mA
Voltage measurement Range 60 V range -6.0000 V to 60.0000 V -6.0000 V to 60.0000 V
6 V range -1.0000 V to 6.0000 V -1.0000 V to 6.0000 V
Accuracy *3 60 V range ± (0.05 % of reading + 0.02 % of rating) ± (0.05 % of reading + 0.02 % of rating)
6 V range ± (0.05 % of reading + 0.04 % of rating) ± (0.05 % of reading + 0.04 % of rating)
Resolution *4 0.1mV 0.1mV
Power measurement Range 0.000 W to 3000.000 W 0.0 W to 12000.0 W
Accuracy Software calculation (voltage measurement × current measurement)
Resolution 1mW 100mW
Current Capacity calculation Range 0.000 Ah to 2000.000 Ah 0.000 Ah to 2000.000 Ah
Accuracy Depends on the current measurement accuracy and the time accuracy
Resolution 1mAh 1mAh
Time*5 Accuracy *3, *6 ±10 ppm (TYP values) ±10 ppm (TYP values)

*1 Range might be different depending on power supply to be connected, model of electronic load, wiring situation, etc.
*2 Lowest dischargeable voltage might be different depending on electronic load model to be connected, wiring situation, etc.
*3 Ambient temperature at 18 °C to 28 °C
*4 Common with 6 V/60 V ranges
*5 Accuracy of transit times (termination condition) at charge/discharge time and at rest.
*6 Corresponding to 30 seconds of monthly difference.

 
PFX2500 series specification comparison
 

Item PFX2512 PFX2532
Rating 60 V / 50 A 60 V / 200 A
Communication interface LAN LAN
Monitoring data minimum time interval 0.1 s 0.1 s
High speed data sampling *4 ✔ (Selected form 1 ms/10 ms/ 100 ms maximum 6000 points for every profile)
Charge/discharge mode 9 modes
Charging: CC, CC-CV(Cell CV Voltage) *1
Discharging: CC, CP,CC-CV(Cell CV Voltage) *1 , CP-CV(Cell CV Voltage) *1
Others: Pattern(CC, CP, Cell CV voltage *2 ), I-V, Pause
Test condition configuration Individual Profile Setting (unlimited) for Charging/Discharging, etc
Conditional branching function from charge/discharge results is available.
Seamless charge/discharge ✔ (Response within 50 ms (TYP) *3 )
Rest time control The time variable by cell temperature

*1 Can be set only when the optional OP02-PFX Volt/Thermometer Unit or OP03-PFX Voltmeter Unit is installed.
*2 Can be set only when the optional OP02-PFX Volt/Thermometer Unit or OP03-PFX Voltmeter Unit is installed. Step time can be used in more than 500 ms.
*3 It is defined as the time for the charge/discharge current to change from 10 % to 90 % of the preset value (ratedvalue).
*4 The main body voltmeter/ammeter is applicable. (Cell voltmeters are not supported.)

Get Adobe' Reader'