KIKUSUI High-rate Battery Tester PFX2731S

Enables high-rate charge/discharge tests necessary for enhanced rapid charge/discharge performance.

The PFX2731S is a 6 V-20 A 6-channel battery tester that supports high-rate charge/discharge tests. It is operated with the application software BPChecker4000, which is exclusive to the PFX2731S. As one PC can operate up to 4 units (24 channels), one can construct a multi-channel charge/discharge system according to the required number of channels.
 
In order to safely conduct long-term continuous testing, it also has 2-system independent protection functions for hardware and software, as well as various protection functions such as a connection confirmation function that detects incorrect wiring and integrated capacity protection.

High-rate Battery Tester

Model:

PFX2731S

Maker:

KIKUSUI ELECTRONICS CORPORATION

Download Materials

Features

  • 10 ms continuous measurement (at the fastest setting)
  • Supports single cell evaluation (C-rate can be set)
  • Various charge/discharge modes (9 modes in total)
    Charge: CC, CC-CV, CP, CP-CV
    Discharge: CC, CC-CV, CP, CP-CV
    Pattern Charge/Discharge (CC(+CV), CP(+CV))
  • When an error is found, a built-in path switch immediately terminates the test.
  • Four thermostatic chambers (produced by Espec) can be operated synchronously
  • A T-type thermocouple (optional) can be used to measure temperature.
  • The system can be set up by connecting a LAN cable.
  • Enhanced protection functions

Specifications

Item Specifications
Nominal input rating 200 Vac to 240 Vac, 50 Hz / 60 Hz, single phase
Input voltage range 180 Vac to 250 Vac
Maximum power consumption 1870 VAmax. in 1 frame (6 ch) at rated charge
Environmental conditions Operating temperature 0 °C to 40 °C
Humidity range 20 %rh to 85 %rh (no condensation)
Storage temperature -10 °C to 60 °C
Humidity range 0 %rh to 90 %rh (no condensation)
Operating environment Indoors, overvoltage category II
Altitude Up to 2000 m
Isolation voltage Between I/O terminals and chassis Maximum ±50 V
Insulation resistance Between primary and chassis 500 Vdc, 30 MΩ or greater, 70 %rh humidity or less
Between primary and I/O terminals *1 500 Vdc, 30 MΩ or greater, 70 %rh humidity or less
Between I/O terminals and chassis *1 50 Vdc, 30 MΩ or greater, 70 %rh humidity or less
Withstanding voltage Between primary and chassis No abnormalities at 1500 Vac for 1 minute.
Between primary and I/O terminals *1 No abnormalities at 1500 Vac for 1 minute.
Dimensions (mm(inch))(maximum dimensions) 430(16.93)(MAX 440(17.32))W×173(6.81)H× 620(24.41)MAX 695(27.36)D mm(inch)
Weight Approx. 34 kg (75 lbs)
Accessories Power cord × 1, Rear panel cover set × 1, Temperature measurement boxes × 6, Temperature measurement cables × 6,TRIP connector × 1, Signal I/O connector × 1, LAN cable × 1, Heavy object warning label × 1, Operation Manual(Japanese and English,one each) × 1, Safety Information × 1, China RoHs sheet × 1

*Cable set is not included.
 Please purchase the optional cable set together with the main unit.

Electromagnetic compatibility *2 *3 Complies with the requirements of the following directive and standard.
EMC Directive 2014/30/EU *3
EN 61326-1 (Class A *4)
EN 55011 (Class A *4, Group 1 *5)
EN 61000-3-2
EN 61000-3-3

Applicable under the following conditions:
Cables and wires to be connected to this product are,
All use less than 5 m

Safety *2 Complies with the requirements of the following directive and standard.
Low Voltage Directive 2014/35/EU *3
EN 61010-1 (Class I *6 , Pollution Degree 2 *7)
EN 61010-2-030

*1 The input/output terminals refer to charging and discharging terminals connected to the DUT, voltage sensing terminal, and external signal input/output.
*2 Does not apply to specially ordered or modified products.
*3 Only for products with CE marking / UKCA marking on their body.
*4 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*5 This product belongs to Group 1 products. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.
*6 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*7 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.

 

Unless specified otherwise, the specifications are for the following settings and conditions.

  • The product is warmed up for at least 30 minutes.

 

The used terminology is as follows:

  • TYP: These are typical values that are representative of situations where the product operates in an environment with an ambient temperature of 23 °C (73.4 °F). These values do not guarantee the performance of this product.
  • setting: Indicates a set value.
  • reading: Indicates a readout value.
  • rating: Indicates a rated value.
  • Static: General term to indicate CC charge, CC – CV charge, CC discharge, CC – CV discharge, CP discharge, and CP – CV discharge.
  • Pattern: General term to indicate pattern charge/discharge.

 

C-rate entry is supported.

  • Individual CC values, pattern charge/discharge step current, limit current, current capacity of end condition/It cutoff current can be set using a C-rate.
  • C-rate calculation specifications The nominal capacity setting value is assumed to be 1C.
  • C-rate setting range: 0.001 to 99.999 (the range is common.)
  • The conversion result from a C-rate to a current/capacity value is rounded to the nearest con- trol resolution.