This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
5-megapixel 2D spectroradiometer
The SR-5100 2D spectroradiometer delivers high-resolution 5-megapixel (2448×2048) spectral imaging with 1 nm wavelength resolution and measurement capability up to 17,000,000,000 cd/m². Designed for micro LED, OLED, LCD, automotive lighting, material analysis, and spectral evaluation, it enables non-contact, non-destructive luminance, chromaticity, reflectance, and transmittance measurement across millions of pixels in R&D and advanced production environments.
Features
■ High resolution 5 million pixels (2448×2048) and high luminance (17 billion cd/m2) spectral measurement
■ Non-destructive and non-contact, 5 million points of spectral evaluation of the characteristics of light sources and objects such as wavelength characteristics of light sources, spectral transmittance characteristics of materials, and spectral reflectance characteristics of objects can be performed with high accuracy.
■ Imaging spectroradiometer with the same performance as a spot type spectroradiometer.
■ Highly accurate brightness and chromaticity accuracy is guaranteed by calibration using a light source with traceability.
■ High-precision and high-speed convertible model that takes advantage of both of the measurement methods of spectral and XYZ filters.
■ Software included as standard.
Principal use
■ Luminance / chromaticity and spectral evaluation of LCDs, OLEDs, QDs, lasers, micro LEDs and related components
■ Emission distribution characteristics and spectral evaluation of automobile meter panels and interior / exterior lighting
■ Evaluation of luminance / chromaticity mura and spectral of the light emitting part of LED lighting and OLED lighting
■ Spectral evaluation of all objects in the landscape indoors and outdoors
■ Spectral evaluation of textile dyed fabrics
■ Skin care assessment of skin blemishes and pigmentation
■ Analysis of absorption, reflection and transmission characteristics
■ Measurement of film and glass coating mura and interference fringes
■ Analysis and quantification evaluation of slight differences in the staining status of pathological tissue (SR-5100HM + microscope)
Specifications
| Measurement mode | Spectral Mode |
| Detector | 5.0 mega pixel CMOS image sensor |
| Objective lens | Standard lens : Focal length f=32mm Standard lens with wide attachment lens : Focal length f=24mm (*1) Telephoto lens : Focal length f=140mm Macro lens *Lens selection type |
| Effective pixel | 2448×2048 |
| Measurement range(*2) | 0.5~17,000,000,000 cd/m2 |
| Wavelength range | 380~780nm |
| Spcetral accuracy(*4) | ±0.5 nm (On the wavelength of Hg emission line) |
| Spectral band width (*5) | 7 nm (Half width) |
| Wavelength resolution | 1 nm |
| Linearity in luminance | ±2% (*3,*6) |
| Chromaticity accuracy | Standard lens with wide attachment lens・Macro ±0.0035 (*3,*6) ±0.0025 (*3,*6) ±0.005 (*6,*9) Telescope ±0.0035(≦1cd/m2) (*3,*6) ±0.0030(1cd/m2<) (*3,*6) ±0.005(*6,*9) |
| In-plane uniformity(*10) | Luminance:±2% Chromaticity:±0.003 |
| Repeatability | Standard lens with wide attachment lens・Macro Luminance:0.6%(≦1cd/m2) (*3,*6,*7) 0.5%(1cd/m2<) (*3,*6,*7) Chromaticity(x,y):0.003(≦1cd/m2) (*3,*6,*8) 0.002(1cd/m2<) (*3,*6,*8) Telescope Luminance:0.8%(≦1cd/m2) (*3,*6,*7) 0.5%(1cd/m2<) (*3,*6,*7) Chromaticity(x,y):0.004(≦1cd/m2) (*3,*6,*8) 0.003(1cd/m2<) (*3,*6,*8) |
| Interface | USB3.0 / External trigger |
| Power supply | AC100 – 240V(50/60Hz) Dedicated AC adapter (Standard accessory) |
| Power consumption | Approx. 20W |
| Operating condition | Temperature: 0 – 35℃ Humidity : 80%R.H. or less(No condensation) |
| External dimensions | Wide type : W162×H247×D402.4 mm Telephoto type: W162×H247×D412.5 mm Macro type : W162×H247×D330.5 mm *(Protruding parts are not included) |
| Weight | Wide type : Approx. 6.3kg Telephoto type: Approx. 8.2kg Macro type : Approx. 5.8kg |
*1 Standard lens with wide attachment lens
*2 Standard illuminant A,
*3 Standard illuminant A,
*4 Hg, Hi precision mode
*5 FWHM, Hi precision mode
*6 At the center of sensor
*7 Within 2σ
*8 Max value – Min value
*9 Standard illuminant A + our standard colored glass filters.
*10 Center of the sensor, Standard illuminant A, within 80% of field of view
| Measurement mode | XYZ(Filter) Mode |
| Detector | 5.0 mega pixel CMOS image sensor |
| Objective lens | Standard lens : Focal length f=32mm Standard lens with wide attachment lens : Focal length f=24mm (*1) Telephoto lens : Focal length f=140mm Macro lens *Lens selection type |
| Effective pixel | 2248×2048 |
| Measurement range (*2) | 0.005~100,000 cd/m2 |
| Linearity in luminance | ±3.5%(≦1cd/m2) (*2,*3) ±3.0%(1cd/m2<) (*2,*3) |
| Chromaticity accuracy | Standard lens with wide attachment lens・Macro ±0.0085(≦1cd/m2) (*3,*6) ±0.0050(≦0.05cd/m2) (*3,*6) ±0.0030(0.05cd/m2<) (*3,*6) ±0.008 (*6,*9) Telescope ±0.0090(≦1cd/m2) (*3,*6) ±0.0050(≦0.05cd/m2) (*3,*6) ±0.0030(0.05cd/m2<) (*3,*6) ±0.008 (*6,*9) |
| In-plane uniformity (*10) | Luminance:±2% Chromaticity:±0.003 |
| Repeatability | Standard lens with wide attachment lens・Macro Luminance:0.70%(≦1cd/m2) (*3,*6,*7) 0.35%(1cd/m2<) (*3,*6,*7) Chromaticity(x,y):0.006(≦1cd/m2) (*3,*6,*8) 0.004(≦0.05cd/m2) (*3,*6,*8) 0.002(0.05cd/m2<) (*3,*6,*8) Telescope Luminance:0.90%(≦0.01cd/m2) (*4,*7,*8) 0.35%(0.01cd/m2<) (*4,*7,*8) Chromaticity(x,y):0.009(≦1cd/m2) (*3,*6,*8) 0.004(≦0.05cd/m2) (*3,*6,*8) 0.002(0.05cd/m2<) (*3,*6,*8) |
| Interface | USB3.0 / External trigger |
| Power supply | AC100 – 240V(50/60Hz) Dedicated AC adapter (Standard accessory) |
| Power consumption | Approx. 20W |
| Operating condition | Temperature: 0 – 35℃ Humidity : 80%R.H. or less(No condensation) |
| External dimensions | Wide type : W162×H247×D402.4 mm Telephoto type: W162×H247×D412.5 mm Macro type : W162×H247×D330.5 mm *(Protruding parts are not included) |
| Weight | Wide type : Approx. 6.3kg Telephoto type: Approx. 8.2kg Macro type : Approx. 5.8kg |
*1 Standard lens with wide attachment lens
*2 Standard illuminant A,
*3 Standard illuminant A,
*4 Hg, Hi precision mode
*5 FWHM, Hi precision mode
*6 At the center of sensor
*7 Within 2σ
*8 Max value – Min value
*9 Standard illuminant A + our standard colored glass filters.
*10 Center of the sensor, Standard illuminant A, within 80% of field of view
Measurement area
SR-5100HWS:Standard lens
| Measurement distance [mm]* | 400 | 500 | 1000 | 1500 | 2000 | 2500 |
| Horizonal [mm] | 1780 | 221.5 | 435.9 | 649.7 | 866.2 | 1072.5 |
| Vertical [mm] | 148.9 | 185.3 | 364.7 | 543.5 | 724.7 | 897.2 |
| Inch [diagonal] | 9.1 | 11.4 | 22.4 | 33.3 | 44.5 | 55.1 |
SR-5100HWS:Standard lens with wide attachement lens
| Measurement distance [mm]* | 400 | 500 | 1000 | 1500 | 2000 | 2500 |
| Horizonal [mm] | 246.6 | 303.0 | 587.5 | 869.9 | 1155.0 | 1437.5 |
| Vertical [mm] | 206.3 | 253.5 | 491.5 | 727.8 | 966.2 | 1202.7 |
| Inch [diagonal] | 12.7 | 15.6 | 30.2 | 44.7 | 59.3 | 73.8 |
SR-5100HT: Telescope lens
| Measurement distance [mm]* | 600 | 1000 | 1500 | 2000 | 2500 |
| Horizonal [mm]** | 60.5 | 108.6 | 168.9 | 229.0 | 288.7 |
| Vertical [mm]** | 50.6 | 90.9 | 141.3 | 191.6 | 241.6 |
| Inch [diagonal] | 3.1 | 5.6 | 8.7 | 11.8 | 14.8 |
SR-5100HM: Macro lens
| Measurement distance [mm]* | 6 |
| Horizonal [mm]** | 6.8 |
| Vertical [mm]** | 5.7 |
| Inch [diagonal] | 0.3 |
** This is production on order.