This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

ITEMLIST
Products Infomation

Myway Plus - Battery Charge & Discharge System pCUBE-CDS -
[Contact Us]
Myway Plus' Battery Charge & Discharge System, equipped with the pCUBE power supply, enables efficient battery testing immediately after purchase. Incorporating high-speed communication and series/parallel expansion, the system includes 16 voltage and 32 thermocouple channels. Drag-and-drop programming, with automatic termination for anomalies, ensures user-friendly operation. Data is stored as CSV, accessible without evaluation, pending CE Marking in the EU.
Battery Charge & Discharge System
Model:
pCUBE-CDS
Maker:
Myway Plus
Special Characteristics
・Availability of ALL Necessary Equipment
・Easy Creation of Test Program on GUI
・Simple Formation of Continuous Program by Grouping Function
・Real Time Monitor of Status and Temperature of Battery Cells
・Automatic Termination during Anomalies
・Easy Management of Test Result CSV Files
Features
1.Availability of ALL Necessary Equipment
Battery charge and discharge system consists of bidirectional power supply (pCUBE), data logger, controller for charge and discharge, PC for operation and application for measurement in one rack. Data logger has 16ch for voltage and 32ch for thermocouple as a standard. Battery pack testing can be executed immediately after purchasing this system.
Easy Creation of Test Program on GUI
In the test program, the test pattern is created easily by drag and drop of 15 basic command icons on EDIT window. Various parameters and commands are set on the parameter window. Without training, users can create and modify test program easily.
Simple Formation of Continuous Program by Grouping Function
One program has 4-step-structure as program > pattern > step > command. By combining repeated patterns and steps into a group, users can easily create complex test for repetition.
Real Time Monitor of Status and Temperature of Battery Cells
Measured cell voltages or temperatures through thermocouple are recorded by data logger. Charging and discharging command that corresponds to the cell voltage are also prepared in basic commands. Users can execute the program while measuring each temperature of the battery and checking monitor.
Automatic Termination during Anomalies
A termination condition can be set before executing the test program. When abnormal voltage or temperature is detected, the program will be automatically terminated.
Easy Management of Test Result CSV Files
The test result data are saved as CSV files. Without actual evaluation test, users are still able to access to test result data.