The RDT-308 by ECG KOKUSAI evaluates rotation direction and magnetic flux distribution in stator coils, supporting 2 to 16 poles with a 16-pole detector. It features automatic pole detection, gain adjustment, and overcurrent protection. Via sensors, the device combines magnetic flux waveforms to deduce rotation direction and intensity. It also identifies abnormalities in winding connections, enhancing accuracy when the detector is centrally placed in the stator bore.

Rotation Direction Tester

Model:

RDT-308

Maker:

ECG KOKUSAI

Download Materials

Features

・Simple and precise direction-of-rotation testing with two test modes.

・Automatic sensitivity adjustment function for testing with optimum detection sensitivity.

・Up to 16 stator coils can be tested with one detector.

・Communication function enables settings, results data transmission and automation to external devices.

Overview

The direction of rotation tester RDT-308 applies a 3-phase or single-phase current to a stator coil and measures the direction of rotation, distribution and variation of the magnetic flux generated by the current using a detector (detection sensor) installed in the stator coil.
The system supports stator coils with up to 16 poles, and can also test 12 / 8 / 6 / 4 / 2 poles when a 16-pole detector is used. A full range of functions such as automatic pole number detection, automatic gain and overcurrent protection are also available.

Test mechanism

Test mode 1 Rotation direction inspection

The waveforms of multiple magnetic fluxes detected by the detector are combined into two waveforms, phase A and phase B, and the overall direction of rotation and intensity are determined from the phase difference and amplitude.


 

Test mode 2 Inspection of phase difference and magnetic field strength by magnetic field distribution

 

Detects abnormalities in all magnetic fluxes and magnetic flux distributions measured by the multiple sensor coils built into the detector. Partial magnetic flux disturbances can be captured even when the overall direction of rotation is normal, leading to the detection of abnormalities in windings and connections. Although the detector must be positioned in the centre of the stator bore, more accurate testing can be carried out.

Demonstration software introduction

Specification

Test item Test mode 1 Direction of rotation test (CW/CCW)
Test mode 2 Magnetic field distribution test (phase difference/magnetic field strength)
Excitation voltage Phase type 3-phase / single-phase
Output waveform 3-phase / 2-phase Sine wave output
Frequency 5kHz
Excitation voltage (Setting range) Phase 5Vp-p (100 steps)
Max. applied current 500mA
Detection Sensitivity Range 10 steps+Auto setting range mode
Protection functions Overcurrent protection
Protection functions Power consumption 100 – 240VAC ±5% 50/60Hz
40VA or less
Environment Temperature range5℃-40℃ Humid range20%-80%
Communication SIGNAL IO / RS-232C
Dimensions/Weights 192(W)×95(H)×235(D) 1.8Kg
Accessories Power cable (3m)     1 unit
3P-2P conversion adapter  1 unit
Diteotor Cable(1.5m)   1 unit
Excitation signal cable (1.5m)  1 unit
Normal Ditector Coil  1 unit
Manual      1unit
Spare Fuse(1A)  1unit
Sold separately ※1 Detector
※1 Detector cable 1.5 m

※1 Detectors should be ordered separately after selecting the model that matches the test object from the compatibility table below.