global
AIKOH Automotive Electrical Components Feeling Tester 1910 Series | Denkei Corporation Americas Send us a message
product

ITEMLIST

Products Infomation

AIKOH Automotive Electrical Components Feeling Tester 1910 Series

Use for in-vehicle switch ( Push type, Rotary type, Lever type) feeling tests.

The Aikoh Feeling Tester 1910 Series is a highly precise instrument designed for evaluating and quantifying tactile sensations. It is ideal for applications in material testing, product design, and quality control, providing accurate measurements to assess the "feel" or texture of various surfaces and products.

This series is equipped with advanced sensors and customizable testing modes, allowing for detailed analysis of pressure, friction, and other tactile properties. With user-friendly software and a robust design, the Aikoh Feeling Tester 1910 Series is a reliable tool for industries such as automotive, consumer electronics, and packaging, where tactile feedback is critical for product success.

Automotive electrical components Feeling Tester

Model:

1910 Series

Maker:

AIKOH ENGINEERING CO., LTD.

Feeling Tester 1910 Series

 

MODEL Max. load Test speed Load display resolution Max. measuring range
1910/1

(Push type)

200N 2~600 mm/min. variable 0.01N 145 mm
1910/2

(Rotary type)

2000mN・m 6~600 mm/min. variable 2000.0mN・m 400.0 deg
1910/3

(Lever type)

200N 6~600 mm/min. variable 200.00N ± 90.0 deg

 


Feeling Tester MODEL-1910/1(Push type)

  • Feeling (load-distance) test of on-board push switches.
  • Waveform data shown on a PC in real time.
  • Switch ON-OFF point detection; 8 points max.
  • Any of non-voltage contact measurement, contact voltage drop point measurement and resistance measurement selectable.

Specifications

 

Mdel 1910/1
Main unit and controller specifications
Max. load 200N
Test speed 2~600 mm/min. variable
Move speed Low, middle, high
Load detection method Load cell Model 3020
Load display resolution 0.01N
Measuring load accuracy ±0.2%F.S.
Distance detection method Motor pulse
Max. measuring range 145 mm
Distance measurement accuracy Within ±0.05 mm
Contact ON-OFF point detection 8 contacts, non-voltage or voltage drop point
Contact resistance measurement Voltage drop measurement
Control PLC
Tester – PC communication Ethernet
Dimensions W600 x D700 x H2052 mm
Mass Approx. 240 Kg
Power supply 100VAC/200VAC ±10%
Jig/fixture (Optional)
Manual X-Y stage Manual X-Y stage±100mm
Manual tilt-horizontal rotary stage Tilt ±90 deg, rotation 360 deg
Standard set Tester
Load cell Model 3020
Dedicated software
Options Personal computer
Manual X-Y stage
Manual tilt-horizontal rotary stage

 


Feeling Tester MODEL-1910/2(Rotary type)

 

  • Feeling (torque-angle) test of on-board rotary switches.
  • Waveform data shown on a PC in real time.
  • Switch ON-OFF point detection; 8 points max.
  • Any of non-voltage contact measurement, contact voltage drop point measurement and resistance measurement selectable.

Specifications

 

Model 1910/2
Main unit and controller specifications
Max. load 2000mN・m
Test speed 6~600 mm/min. variable
Move speed Low, middle, high
Torque detection method Torque meter Model QFR-02K
Torque display resolution 2000.0mN・m
Measuring load accuracy ±0.3%F.S.
Angle detection method Motor pulse
Max. measuring range 400.0 deg
Distance measurement accuracy Within ±0.1 deg
Contact ON-OFF point detection 8 contacts, non-voltage or voltage drop point
Contact resistance measurement Voltage drop measurement
Control PLC
Tester – PC communication Ethernet
Dimensions W600 x D700 x H2052 mm
Mass Approx. 240 Kg
Power supply 100VAC/200VAC ±10%
Jig/fixture (Optional)
Manual X-Y stage Manual X-Y stage±100mm
Manual tilt-horizontal rotary stage Tilt ±90 deg, rotation 360 deg
Standard set Tester
Torque meter Model QFR-02K
Dedicated software
Options Personal computer
Manual X-Y stage
Manual tilt-horizontal rotary stage

 


Feeling Tester MODEL-1910/3(Lever type)

 

  • Feeling (load-angle) test of on-board lever switches.
  • Waveform data shown on a PC in real time.
  • Switch ON-OFF point detection; 8 points max.
  • Any of non-voltage contact measurement, contact voltage drop point measurement and resistance measurement selectable.

 

Specifications

 

Model 1910/3
Main unit and controller specifications
Max. load 200N
Test speed 6~600 mm/min. variable
Move speed Low, middle, high
Load detection method Load cell Model 3020S
Load display resolution 200.00N
Measuring load accuracy ±0.2%F.S.
Angle detection method Motor pulse
Max. measuring range ± 90.0 deg
Distance measurement accuracy Within ±0.1 deg
Contact ON-OFF point detection 8 contacts, non-voltage or voltage drop point
Contact resistance measurement Voltage drop measurement
Control PLC
Tester – PC communication Ethernet
Dimensions W600 x D700 x H2052 mm
Mass Approx. 240 Kg
Power supply 100VAC/200VAC ±10%
Jig/fixture (Optional)
Manual X-Y stage Manual X-Y stage±100mm
Manual tilt-horizontal rotary stage Tilt ±90 deg, rotation 360 deg
Standard set Tester
Load cell Model 3020S
Dedicated software
Options Personal computer
Manual X-Y stage
Manual tilt-horizontal rotary stage

Get Adobe' Reader'