global
TOPCON Digital Illuminance Meter IM-600 / IM-600M | Denkei Corporation Americas Send us a message
product

ITEMLIST

Products Infomation

TOPCON Digital Illuminance Meter IM-600 / IM-600M

Ideal for evaluating next generation lighting with wide range illuminance measurement.

This product is a high-precision, high-reliability illumination meter, meticulously designed to comply with the JIS standard general type AA class. Its exceptional accuracy and dependable performance make it an ideal tool for professionals who demand the highest standards in their measurements.

The product boasts a wide range and excellent operability, ensuring it is perfectly suited for evaluation management of next-generation lighting and similar applications. Our lineup includes two models to cater to diverse needs: the standard IM-600 and the IM-600M. The IM-600M features a detached receiver, making it specifically advantageous for use in small or confined areas.

Digital Illuminance Meter

Model:

IM-600 / IM-600M

Maker:

TOPCON TECHNOHOUSE CORPORATION

Download Materials

Features

  • Wide range measurement (0.005 – 999,000 lx).
  • Display unit and light sensing unit are Separable with optional cable(IM-600).
  • Multiple measurement function.
  • Response time, screen flicker can be measured with oscilloscope.
  • Zero calibration function without cap can be installed equipment.

Use

  • Development and design department for lighting equipment maker.
  • Lighting system performance evaluation for building constructor.
  • Management of light source for plant factory.
  • Maintenance and management of light in factory, school, office, etc.
  • As a measurement sensor of production line or a variety equipments.

Specification

 

Item Specification
JIS Class Conforms to the general AA class illuminance meter.
(JIS C 1609-1-2006)
Photo detector Silicon photo diode
Measurement
Range
0.005 – 999,000 lx
Cosine Correction

Characteristics

​【IM-600】​
10°: Within ±1%
30°: Within ±1%
50°: Within ±5%
60°: Within ±5%
80°: Within ±10%
​【IM-600M】​
10°: Within ±1%
30°: Within ±2%
50°: Within ±6%
60°: Within ±7%
80°: Within ±25%
Relative Spectral

Response

6% or less (*1)
Linearity ±2% of rdg. ±1 digit (Auto Range)
Measurement
Mode
Auto / Manual (6 range)
Measurement
Function
Standard measurement:
Illuminance(lx), Integrated illuminance(lx・h), Integration time(h), Luminous intensity(cd)
Deviation measurement:
Illuminance difference(lx), Illuminance ratio(%)
Calibration
Function
CCF (Color Correction Factor) setting
Analog Output 0 – 3V
Interface USB
Power Source
Function
Size AA dry-cell battery×2 or Dedicated adapter (Option)
Use conditions Temperature: -10 – +40℃,
Humidity: 85% RH or less (No condensation)
Outer dimensions
(W×D×H)
188×65×34mm, Sensor Unit (IM-600M): 16×21mm
Weight IM-600: 200g, IM-600M: 230g *Non-dry cell battery

Get Adobe' Reader'