global
Send us a message
product

ITEMLIST

Products Infomation

KIKUSUI TOS9300 series

The All-Rounder.Hipot,Insulation Resistance,Ground Bond,Leakage or Partial Dischage,this analyzer covers it all!



 

The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards.

A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D,quality assurance manufacturing lines and laboratory tests.

Electrical Safety Multi-Analyzer

Model:

TOS9300 series

Maker:

KIKUSUI

5 Key Features

1. All-in-One Testing – TOS9303LC model covers AC/DC Hipot, IR, Ground Bond, and Leakage Current in one instrument.

2. High Capacity – AC 5 kV / 100 mA, DC 7.2 kV / 100 W output.

3. 40A AC/DC Ground Bond – New amplifier design supports high-current testing for automotive and EV systems.

4. Full Connectivity – LAN / USB / RS232C standard on all models.

5. User-Friendly Operation – 7-inch LCD with real-time measurement display and stored standard outlines.

Performance Highlights

 

 ・ Insulation Resistance: 0.001 MΩ to 100.0 GΩ

 ・ Ground Bond: 0.001 Ω to 0.600 Ω (3.0 A to 42.0 A)

 ・ Leakage Current: 1 μA to 100 mA (rms) – TOS9303LC

 ・ Partial Discharge Detection – TOS9301PD

 ・ Rise/Fall Time Control for reduced DUT stress

Applications

  • Electrical & Electronic Equipment – Standard safety compliance tests.

 

  • Medical Devices – Leakage current (patient current) testing.

 

  • Automotive Components – EV/PHV systems, charging connectors.

 

  • PV Modules – Withstanding voltage & insulation resistance testing.

Model Comparison

Model AC Hipot DC Hipot IR GB LC PD
TOS9300
TOS9301
TOS9301PD
TOS9302
TOS9303
TOS9303LC

Video

TOS9300 Series – Specifications Overview

Model AC Hipot Test DC Hipot Test Insulation Resistance Test Ground Bond Test Leakage Current Test Partial Discharge Test Key Features
TOS9300 5 kV / 100 mA (500 VA) 0.001 MΩ to 100.0 GΩ (DC -25 V to -1000 V) Basic model. AC Hipot + Insulation Resistance measurement
TOS9301 5 kV / 100 mA (500 VA) 5 kV / 20 mA, 7.2 kV / 13.9 mA (100 W) 0.001 MΩ to 100.0 GΩ (DC -25 V to -1000 V / DC +50 V to +7200 V) AC/DC Hipot and high-voltage Insulation Resistance measurement
TOS9301PD 5 kV / 100 mA (500 VA) 5 kV / 20 mA, 7.2 kV / 13.9 mA (100 W) 0.001 MΩ to 100.0 GΩ (DC -25 V to -1000 V / DC +50 V to +7200 V) Partial discharge measurement (0.1 pC resolution) AC/DC Hipot + Insulation Resistance + Partial Discharge test in one unit
TOS9302 5 kV / 100 mA (500 VA) 0.001 Ω to 0.600 Ω (3 A to 42 A) AC Hipot + Ground Bond dedicated model
TOS9303 5 kV / 100 mA (500 VA) 5 kV / 20 mA, 7.2 kV / 13.9 mA (100 W) 0.001 MΩ to 100.0 GΩ (DC -25 V to -1000 V / DC +50 V to +7200 V) 0.001 Ω to 0.600 Ω (3 A to 42 A) AC/DC Hipot + Insulation Resistance + Ground Bond test
TOS9303LC 5 kV / 100 mA (500 VA) 5 kV / 20 mA, 7.2 kV / 13.9 mA (100 W) 0.001 MΩ to 100.0 GΩ (DC -25 V to -1000 V / DC +50 V to +7200 V) 0.001 Ω to 0.600 Ω (3 A to 42 A) 1 μA to 100 mA (rms) AC/DC Hipot + Insulation Resistance + Ground Bond + Leakage Current test