global
ADCMT IR Meter 4000 / 4005X Series | Denkei Corporation Americas Send us a message
product

ITEMLIST

Products Infomation

ADCMT IR Meter 4000 / 4005X Series

Maximum 4 channels mountable modular-system IR meter

The IR meter consists of the compact mainframe 4000 having two slots and the modular units 40051, 40052, 40053 and 40054. It configures up to 4 channels by combining the modular units.

In recent years, it is necessary to improve the takt time of manufacturing and inspection in production lines of parts or components.

Consequently, measuring instruments used in these production lines require higher measuring speed, multiple channels. space saving and other optimal functions.
This IR meter can satisfy such needs by adopting the modular system.

IR Meter

Model:

4000 / 4005X Series

Maker:

ADC CORPORATION

Download Materials

Features

4000 2-slot modular instrument

The 4000 is a 2-slot modular instrument of 2U half-size mainframe to which 2 units of 0.7U half-size modules can be installed.
It is equipped with various interfaces; USB, GPIB, LAN and RS232, making it possible to build inspection systems for R&D or production lines of electronics components by connecting to a personal computer or programmable controller.
In addition, the 4-channel handler interface allows you timing control with automatic machines, and device selection according to measurement and judgment results by the modules. In inspection lines, you can easily perform system setup or maintenance of modules that are mounted on system racks without removal such as module replacement, operation check via USB on the front panel.
Moreover, by using the digital I/O of 8 bits having a 5 V/200 mA power supply, easy relay control and signal generation are available.

 


40051/40052/40053/40054/40057 IR meter units

The 40051, 40052, 40053, 40054 and 40057 IR meter units are to be mounted into the 2-slots modular instrument 4000. The 1-channel 40051, 40053 and 40057 and 2-channel 40052 and 40054 are integration-method IR meters, suitable for current measurement of high-capacity samples such as capacitors.
The current measurement range is from 10 fA to 3.2 mA, and the voltage source range is up to ±200 V/3.2 mA for the 40051 and 40052, up to +300 V or -100 V/3.2A for the 40053 and 40054, or up to +2000 V/0.8 mA or ±200 V/3.2 mA for the 40057. The resistance measurement range is between 312 Ω to 3×1017 Ω.
In addition, it has a contact check function (C.CHK) by capacity (C) measurement to judge the contact status of high resistance samples.
Moreover, the handler interface signals to be controlled from automatic machines in production lines are directly output to the rear connectors on the 4000.


1-channel IR meter unit

  • 40051 (V source range: 1 mV to ±200 V)
  • 40053 (V source range: 1 mV to +300 V/ -100 V)


The photo is 40051.


2-channel IR meter unit

  • 40052(V source range: 1 mV to ±200 V)
  • 40054(V source range: 1 mV to +300 V/-100 V)


The photo is 40052.


1-channel IR meter unit (2000 V)

  • 40057 (V source range: ±200 V, +50 V to +2000 V)


Measurement timing and measurement time

Specification

 

Model 4000+40051/40052 4000+40053/40054 4000+40057
Number of channels 1 to 4 1 to 2
Number of digits, maximum display 5½ digits、319999
Floating voltage 200 V 300 V 0 V
Measurement Current Range 300 pA~3 mA
Minimum resolution  1 fA
Measurement accuracy 0.3 %
Input bias current 100 fA or less
Input resistance 50 Ω/1 kΩ
Resistance

(Calculation)

Measurement range 312 Ω to 316 Ω 312 Ω to 317 Ω
Range (300 pA to 3 mA)
Measurement accuracy  0.35 %
Source Voltage Range -200 V to +200 V -100 V to +300 V -200 V to +2000 V
Minimum resolution 1 mV
Source accuracy 0.03 % 0.03 %(200 V)
0.2 % (2000 V) V
Voltage source range ±30 V/±3.2 mA

±200 V/±3.2 mA

±30 V/±3.2 mA

+300 V, -100 V/±3.2 mA 

±30 V/±3.2 mA

±200 V/±3.2 mA

+50 to +2000 V/0.8 mA 

Voltage limit

10 μA to 3.2 mA

Resolution: 1 μA

10 μA to 3.2 mA

Resolution: 1 μA
0.8 mA/2000 V

Sweep Fixed, linear
Measurement function Integration time 1 ms/2 ms/5 ms/0.5 PLC/1 PLC/100 ms/200 ms  
Measurement speed (IT2 ms)

TRG-INDEX (without CHK)

TRG-INDEX (with CHK)

 

 

2.6

4.1

Data memory   10000 data/channel
Sequence Depending on fixed sweep
Contact check To be executed at every measurement

0.1 pF to 100 pF, 500 kHz/315 kHz, execution time: 1.5 ms

Calculation  RM, COMP
Other functions 4-channel synchronization or

asynchronization

Jig capacity open correction

2-channel synchronization or

asynchronization

Jig capacity open correction

INT CAL Available
 Interface    GPIB, USB, RS232, LAN

 

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.