KIKUSUI High-Capacity Regenerative Electronic Load PXZ Series

High-Capacity Regenerative Electronic Load PXZ Series

The PXZ series of highly efficient, reliable, high-capacity regenerative electronic loads has a rated power of 20 kW in 3U. In addition to the constant-current, constant-resistance, constant-voltage, and constant-power operating modes, this series has an I-V characteristic function that allows the user to set arbitrary I-V characteristics for each CC and CV operating mode. The series is also equipped with various functions, such as sequence, pre-charge, synchronous operation, pulse, sine, and VMCB functions.
 
LAN, USB, and RS232C communication functions are included as standard, allowing easy integration into various evaluation systems. The PXZ series is highly scalable, and its capacity can be increased up to 500 kW when operating in parallel (up to 25 units).

High-Capacity Regenerative Electronic Load

Model:

PXZ Series

Maker:

KIKUSUI ELECTRONICS CORPORATION

Download Materials

Features

  • 20kW rated power in 3U
  • Maximum operating voltage of 1500 V
  • Operating modes: CC, CR, CV, CP
  • Up to 25 units (500 kW) can be operated in parallel
    *Please consult with us if you would like to use 10 or more units in Parallel operation.
  • Equipped with a touch panel display
  • Pre-charge function
  • I-V characteristic function
  • Sequence function
  • LAN, USB, RS232C, external analog control (isolated type) as standard
  • Regenerative efficiency of over 90% (on-site regeneration)

Line up

SKU Output Power [W] Output CV [V] Output CC [A]
PXZ20K-50 20kW 3 to 50 800
PXZ20K-500 10 V to 500 V 120
PXZ20K-1000 20 to 1000 60
PXZ20K-1500 30 V to 1500 V 30

Promotion Videos

Specifications

Rating

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Rated power 20000W
Rated voltage (DC) *1 3V to 50V 10 V to 500V 20V to 1000V 30 V to 1500 V
Rated current *1 800A 120A 60A 30A

*1 Maximum input current and maximum input voltage are limited by maximum input power.

 
Constant voltage (CV) mode

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Maximum settable voltage 52.5V 525V 1050V 1575V
Setting accuracy ±(0.2 % of setting + 0.1 % of rating)
Resolution 0.005V 0.05V 0.1V 0.1V
Remote sensing Maximum compensation voltage (reciprocating) (TYP) 10% of rating
Response switching FAST, SLOW
Slew rate switching (TYP) 12.5V/ms or more *1 125V/ms or more *1 250V/ms or more *1 375V/ms or more *1
12.5V/ms 125V/ms 250V/ms 375V/ms
1.25V/ms 12.5V/ms 25V/ms 37.5V/ms
0.125V/ms 1.25V/ms 2.5V/ms 3.75V/ms
0.0125V/ms 0.125V/ms 0.25V/ms 0.375V/ms

*1 MAX will appear on the display.

 
Constant Current (CC) mode

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Maximum settable current *1 +840A +126 A +63A +31.5 A
Setting accuracy *2 ±(0.75 % of rating)
Resolution 0.1A 0.01A 0.005A 0.002 A
Line regulation *3 ±1600mA ±240 mA ±120mA ±60 mA
Load regulation *4 ±1600mA ±240 mA ±120mA ±60 mA
Rise time(TYP) *5 1 ms
Fall time(TYP) *6 1 ms
Response switching FAST, SLOW
Slew rate switching *1 800A/ms or more *7 120A/ms or more *7 60A/ms or more *7 30A/ms or more *7
400A/ms 60 A/ms 30 A/ms 15 A/ms
200A/ms 30 A/ms 15.0A/ms 7.5 A/ms
20A/ms 3 A/ms 1.50A/ms 0.75 A/ms
2A/ms 0.30A/ms 0.150A/ms 0.075 A/ms

*1. During parallel operation, this will be the value multiplied by the number of units in the configuration.
*2. Applies to a range of 1 % to 100 % of the rated current.
*3. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load.
*4. This is the amount of change when the voltage is changed from the rated voltage and rated power to 1/10 of the rated voltage.
*5. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 10 % to 90 % of the rated current when the input current
value is changed from 0 % to 100 % of the rated current. When the slew rate is set to MAX.
*6. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 90 % to 10 % of the rated current when the input current
value is changed from 100 % to 0 % of the rated current. When the slew rate is set to MAX.
*7. MAX will appear on the display.

 
Constant resistance (CR) mode

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Conductance rating 160S 2400.0 mS 600.000mS 200.000 mS
Setting range 0S to 168S 0 mS to 2520.0 mS 0mS to 630.000mS 0 ms to 210.000 mS
Setting accuracy *1 ±(0.5 % of setting + 0.5 % of rating)
Resolution 20mS 0.20 mS 0.05mS 0.02 mS
Response switching FAST, SLOW

*1 Converted value at the input current.

 
Constant Power (CP) mode

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Maximum settable power *1 21000W
Setting accuracy *2 ±(0.5 % of power rating + 0.5 % of current rating × Vin)
Resolution 2W

*1 During parallel operation, this will be the value multiplied by the number of units in the configuration.
*2 Applies to a range of 5 % to 100 % of the rated power. Rating indicates the rated current value.

 
General Specifications

Item PXZ20K-50 PXZ20K-500 PXZ20K-1000 PXZ20K-1500
Weight Approx. 41 kg (90.39 lbs) Approx. 38 kg (83.78 lbs) Approx. 37 kg (81.57 lbs) Approx. 37 kg (81.57 lbs)
Dimensions 430 (16.93)(MAX455 (17.91))W × 128 (5.04)(MAX160 (6.30))H × 720 (28.35)(MAX980 (38.58))D mm (inches)
Refer to Outline Drawing
Environmental conditions Operating environment Indoor use, overvoltage category II
Operating temperature 0℃ to +40℃ 0 °C to +50 °C (32 °F to +122 °F)
Operating humidity 20% rh to 85% rh (no condensation)
Storage temperature -25 °C to +60 °C (-13 °F to +140 °F)
Storage humidity 90 % rh or less (no condensation)
Altitude Up to 2000 m
Cooling method Forced air cooling using fan
Accessories AC INPUT terminal cover, External control connector kit (1 set), Chassis connection wire, DC INPUT terminal cover, DC INPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pc.), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 sheet), Getting Started Guide (1 copy), Heavy object warning label (1 piece)
Withstanding voltage Between primary and FG 2200 Vac for 1 minute
Between primary and secondary
Between secondary and FG 500 Vdc for 1 minute 1800 Vdc for 1 minute 3000 Vdc for 1 minute
Insulation resistance Between primary and FG 30 MΩ, 500 Vdc
Between primary and secondary 30 MΩ, 500 Vdc 30 MΩ, 1000 Vdc
Isolation voltage ±250V ±1000V +2000V/-1000V
Electromagnetic compatibility (EMC) *1 *2 Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A *3)
Safety *1 Complies with the requirements of the following directive and standards.
Low Voltage Directive 2014/35/EU *2
EN 61010-1 (Class I *4, Overvoltage category II, Pollution Degree 2 *5)

*1 Does not apply to specially ordered or modified products.
*2 Only for models with CE mark / UKCA mark on their body.
*3 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*5 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.