This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

A simulator to reproduce fast repetitive high frequency pulses which are generated when switching ON/OFF electric current on the inductive load. International Standard IEC 61000-4-4 defines immunity tests for power supply lines or I/O signal lines against fast transient repetitive bursts. Also adopted as a Japan Industrial Standard.
Fast Transient Burst Simulator
Model:
FNS-AX4-A20/B63
Maker:
NOISE LABORATORY CO.,LTD.
Features
- A simulator to reproduce fast repetitive high frequency pulses which are generated when switching ON/OFF electric current on the inductive load. International Standard IEC 61000-4-4 defines immunity tests for power supply lines or I/O signal lines against fast transient repetitive bursts. Also adopted as a Japan Industrial Standard.
- IEC 61000-4-4 Ed.3 standard compliance.
- Pre-check function is installed. Inspection before testing is now easy.
- Normal mode test support. Taking account of field troubles is possible. (option)
- Utilize a tri-color pilot light to carry out safer test. (option)
- Utilize an outlet box that simplifies EUT connection. (option)
- Compared with conventional products, the size has become compact. (Approximately 67% by volume)
- Easy to understand Panel display reduces mistakes in connecting power cables.
- Software control with Android ? and Windows. (option)
- Next calibration date can be notified. (Android / Windows software only)
- Employ LCD screen with multi-language support and enhanced operability.
- Maximum output voltage of 5 kV and maximum pulse frequency of 2 MHz allow you to test above the standard test level.
- CDN capacity is increased to single phase type AC 240V 20A, single and three phase type to AC 600 V 63 A, supporting wider range of EUT.
- Large capacity CDN (100A or 150A) option available for Injection test on various EUT
- Using coupling clamps, EMS probe kits, you can test the signal lines and evaluate the noise immunity on the PCB. (option)
- Easy-to-understand help function. (Android / Windows software only)
Fast Transient Burst Simulator FNS-AX4-A20/B63
Specifications
■ Generator specification ■
Item | Specification / Function |
Output voltage | 200 to 5000 V 10 V Step |
Polarity | Positive or negative, polarity alternation possible per burst |
Repetition frequency | 0.1 kHz to 2000 kHz 0.1 kHz to 1 kHz / 0.01 kHz step Tolerance ± 5% 1.0 kHz to 10 kHz / 0.1 kHz step Tolerance ± 5% 10 kHz to 100 kHz / 1 kHz step Tolerance ± 5% 100 kHz to 1000 kHz / 10 kHz step Tolerance ± 5% 1000 kHz to 2000 kHz / 100 kHz step Tolerance ± 10% (Limitation per voltage levels when continuous output) |
Number of pulses | 1 to 1000 at a step of 1 pulse |
Burst duration | Setting limit: 1 pulse per ms in a burst (repetition frequency 1 kHz or more) Formula for Burst duration = Pulse number / Repetition Frequency Scope of manually setting value for burst duration: 0.01 to 999 ms |
Burst period | 10 to 1000ms ± 10% 10ms steps (500ms or more for polarity alternate mode) |
Polarity alternate function | Output polarity alternated between positive and negative at each burst period Setting condition: the burst period is 500ms or more and the burst pause period [(burst period) – (burst duration)] is 100ms or more Maximum test time: 10 minutes |
Continuous Pulse output | Up to 1000 V-10kHz or less, to 2000V-4kHz or less, to 5000V-1kHz or less. Maximum test time for each case: 10 min |
Frequency modulation | Frequency is shifted continuously between set frequency and approximately -10% from the set frequency. The modulating wave is triangular wave of approximately 20Hz |
External trigger | External trigger input invokes 1 burst output in synchronization with the trigger input. Trigger specification: Hi (+ 5V) → Lo (0 V) triggers one burst period. |
Pulse waveform (at 50 Ω load) | Pulse peak voltage: (set voltage / 2) ± 10% Rise time: 5 ns ± 30% Pulse width: 50 ns ± 30% |
Pulse waveform (at 1 kΩ load) | Pulse peak voltage: (set voltage × 0.95) ± 20% Rise time: 5 ns ± 30% Pulse width: 35 to 150 ns |
DC blocking capacitor | 10nF ± 20% |
■ CDN specification ■
Item | Specification / Function |
Power capacity | A 20 model: Single phase AC 240 V / 20 A, DC 125 V / 20 A (10 A for PE) B 63 model: three-phase AC 600 V / 63 A, DC 125 V / 63 A (10 A for N/PE) |
Applied phase | A20 model: L / N / PE B63 model: L1 / L2 / L3 / N / PE Single line or all lines can be specified individually for each phas |
Injection mode | Common mode (Normal mode available using option) |
EUT Line input/output | φ6 mm safety socket |
Coupling capacitor | 33nF |
Output waveform specification | Pulse peak voltage: (set voltage) / 2 ± 10% Rise time: 5.5 ns ± 1.5 ns Pulse width: 45 ns ± 15 ns Set voltage ± 4000 V, frequency specified from 5 kHz to 100 kHz |
Input residual voltage | 10% or less of setting pulse voltage EUT line input is 50 Ω termination, line output is defined as open |
AC Line Sync | Synchronous and asynchronous setting available. Setting phase angle: 0 to 360 ° ± 10 ° 1 °Step Synchronizable voltage: AC 85 V to rated voltage Reference phase: between L-N (A |
■ Other specifications ■
Item | Specification / Function |
emergency stop | Push lock type switch (Test stop, EUT line OFF) |
EUT FAIL function | FAIL signal from external (Hi → Lo) detected during test FAIL signal specifications VLO: 0 V, VHI: +5V Choose operation from test stop/pause when triggered 3 channels available for the FAIL input |
External interface | REMOTE (For external PC control), CDN I/F (For external CDN), INDICATOR (For Warning Lamp or indicator lamp) EUT FAIL INPUT (For temporary pause at EUT failure event) |
Accessary | Power Cable, SG Cable, Line Input Cable, Output Cable, Waveform Check Connector, Coaxial Cable, Operation Manual, Accessary bag |
Operating environment | Temperature 15 to 35 °C Relative humidity 25 to 75% |
External dimension / Weight | W430 × H199 × D370 mm (excluding protrusions) / Approximately 14 kg (A20 model) and 22 kg (B63 model) |
Power supply | AC100 to 240V ± 10% 50/60 Hz |