MICROTEST Transformer Tester 5266

One Device for Measuring Key Parameters of Transformer Products, Measurement Frequency Range 10Hz-500kHz

MICROTEST 5266 Transformer Tester is a comprehensive device that enables measurement of important parameters for transformer products. It includes inductance, leakage inductance, DC resistance, AC resistance, quality factor, capacitance, turns ratio, and checks for pin short circuits, among other items. The measurement frequency range is from 10Hz to 500kHz. The tester has a built-in LCR meter measurement mode and is equipped with the F5620 pneumatic testing fixture. It provides 20 testing channels and supports 100mA DC bias testing. Customized testing fixture services are available to meet specific customer needs.

Transformer Tester

Model:

5266

Maker:

MICROTEST

All-In-One Low Voltage Electrical Test   

Inductance (L)/Leakage Inductance/Turn Ratio/Resistance (DCR)/Resistance (R)/Balance/Capacitance (C)/Short Circuit.

 

Automatic Balancing Bridge & 4-Wire DCR Test (DC Resistance)

Check if the winding tension is improper for Transformer.

 

Turns ratio is an important parameter in transformer.
Ideally, we can get the turns ratio by compare the input and output voltage. However, there are many parameters that might affect. So, there are some different ways to detect turns ratio.

TR Voltage Put a AC voltage on primary coil, and detect the voltage on secondary coil. Compare the turns ratio and phase
TRL Inductance Detect the inductance on each coil, and calculate the turns ratio. The turns ratio is more accurate on transformer with bigger leakage inductance.

 

Features

  • Test Frequency: 10Hz-500kHz
  • 20 Channels
  • Built-in Meter Mode
  • Simultaneously display four parameters
  • Basic accuracy up to ±0.1%
  • Open circuit/short circuit function
  • RS-232、Handler、LAN、USB Host 、Handler
  • Pneumatic fixture F5620 built-in 100mA DC Bias
  • USB Host storages can storage setting files, data and capture the screen

Application

Detect capacitance to make sure the insulation between winding position and winding coil is enough

  • The winding coil on the transformer include distributed capacitance, it usually distribute between winding coil.
  • Capacitance is usually represented by the capacitance by one winding to another winding in an equivalent circuit.
  • Cs and Cp is an equivalent capacitance in series or parallel in equivalent circuit.
  • D value is the ratio with AC resistance and capacitance, The lower the D value, is better.

 

Test leakage by LCR balance bridge
When the instrument connect a primary coil with the transformer and the secondary coil is under open status, the test result L= Lp on primary coil + Leakage Current.

→The leakage inside the instrument must short the secondary coil in the transformer.
A ideal secondary coil’s voltage will be 0V in short status. The voltage on both side of primary coil will be 0V. The inductance from primary coil will be the real leakage current.

 

Offer 100mA DC Bias Current to fulfill Netcom transformer product.

The purpose of detect DC bias is to make sure the specification of coil winding and magnetic saturation.

  • _The way we detect is put DC signal on AC signal. The DC signal will cause DC bias on inductance of the transformer. It might also cause magnetic saturation on transformer.
  • _Increase inductance by high magnetic conductivity and decrease the turns to minimize the size and raise the efficiency for inductance magnetic coil transformer. Because of the restriction of the permeability material, magnetic flux can’t be unlimited increasing. When it reach the limited, no matter increase the turns or current, the magnetic flux won’t increase. Meanwhile, it will meet the magnetic saturation especially under DC current. The AC current will not cause any change in magnetic flux. The transformer will loose the inductance feature.

The harm of magnetic saturation

  • _The magnetic saturated transformer will overheat under low voltage and cause damage by time.
  • _It may cause explosion under high voltage.
  • _The inductance of primary winding will obliviously decrease on saturated transformer. Meanwhile, the power consumption on DCR and inner MOSEFT will increase rapidly. This may cause the damage on MOSEFT.

 

Detecting Essential Electrical Parameters of Transformers

Specifications

5265/5266/5267
5265 10Hz-200kHz
5266 10Hz-500kHz
5267 10Hz-1MHz

 

Model 5265/5266/5267
Test Channel 20
Frequency Resolution 5 digits
Basic Accuracy ±0.1%
AC Drive Level 10mV-2Vrms
DC Drive Level 10mV-2V
Output Impedance 100Ω
DC Bias Current 100mA (F5620)
Turn Inductance or Voltage

Test Freqeuncy:50Hz-200kHz

Test Mode Meter Mode / List Mode
Parameters Measurement Inductance (L)、Impedance (Z)

Capacitance (C)、Resistance (R)

Conductance (G)、Susceptance (B)

Admittance (Y)

Alternating Current Resistance (ACR)

Quality Factor (Q)、θ

Direct Current Resistance (DCR)

Leakage Inductance

Turn Ratio、Balance

Short Circuit

 

Parameters Range (AC parameter:1kHz)
L, LK 0.1nH ~ 9999.99H

Basic Accuracy 0.10%

Speed 25ms

C 0.00001pF ~ 999.99mF

Basic Accuracy 0.10%

Speed 25ms

Q,D 0.00001 ~ 99999

Basic Accuracy 0.0005

Speed 25ms

Z,X,R 0.00001Ω ~ 99.9999MΩ

Basic Accuracy 0.10%

Speed 25ms

Y 0.01nS ~ 99.9999S

Basic Accuracy  0.1%

Speed 25ms

θ -180°~ +180°

Basic Accuracy 0.03°

Speed 25ms

DCR 0.1mΩ ~ 99.999 MΩ

Basic Accuracy 0.10%

Speed 25ms

Turn 0.1 ~ 99999.9 turns

Basic Accuracy 0.50%

Speed 50ms

Pin-Short 12 pairs, between pin to pin

Speed 15ms

 

ESR Series / Parallel
Calibration Open Circuit / Short Circuit
Built-in stroage testing files 128 sets
Operation Auto / Manual / Remote Trigger
Power Supply Voltage:98Vac-132Vac  or

195Vac-264Vac

Frequency:47-63Hz
Power consumption 300VA
Environment Temperature:10℃-40℃
Humidity:10-90%RH
Dimension (W*H*D) 344x145x343 mm (W*H*D)
Weight 9 Kg
Interface RS-232、Handler、LAN、USB Host

EXT. I/O

Display 800*480 Color Screen, 7″ TFT