This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

The INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.
Impulse Noise Simulator
Model:
INS-AX2-220/250H/420/450H
Maker:
NOISE LABORATORY CO.,LTD.
Features
- An innovative, motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors, allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes, automatic voltage ramp and others.
- As well as manual control, the simulator can be remote-controlled through a fiber optic computer interface. Windows control software is free-downloadable from NoiseKen website.
- Floating output
- 8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
- Internal switchable terminators
- Easily changeable and safety-interlocked outlet panel (EUT interface)
- 3 channels EUT fail input
Specification
Item | Model | ||
INS-AX2-220/250H | INS-AX2-420/450H | ||
Pulse output voltage | 0.01 ~ 2.00kV±10% at 0.01kV step | 0.01 ~ 4.00kV±10% at 0.01kV step | |
±0.04kV allowance for <0.1kV setting | |||
When the output is terminated by the internal resistors. | |||
Output polarity | Positive or negative | ||
Pulse | Pulse width | 50, 100, 200, 400, 500, 800, 1000ns ±10%, 10ns±3ns | |
Rise time | <1ns | ||
Output impedance | 50 ohm system (53.5 ohm) | ||
Pulse repetition mode | Variable | 10ms ~ 999ms±10% | 16ms ~ 999ms±10% |
Phase | Injection phase angle 0 to 360 degrees±10 degrees | ||
EUT power supply:>AC90V, 50/60Hz±10% | |||
1 shot | Single pulse generation, each time the 1 SHOT button is pressed. | ||
Synchronized output with phase angle setting in PHASE mode | |||
Power capacity of EUT | INS-AX2-220: | NS-AX2-420: | |
Single phase AC240V/DC65V 20A | Single phase AC240V/DC65V 20A | ||
INS-AX2-250H: | INS-AX2-450H: | ||
3-phase (4-wire) AC500V/DC250V 50A | 3-phase (4-wire) AC500V/DC250V 50A | ||
50/60Hz±10% | 50/60Hz±10% | ||
Power supply | AC 100V~240V±10%, 50/60Hz±10% | ||
Power consumption | 110VA | ||
Operating temperature and humidity range | 15 ~ 35°C, 25 ~ 75% (No dewing shall occur.) | ||
Dimensions | W 430 x H 350 x D 470mm, projection excluded | ||
Weight | INS-AX2-220: Approx. 30Kg | INS-AX2-420: Approx. 30Kg | |
INS-AX2-250H: Approx. 38Kg | INS-AX2-450H: Approx. 38Kg | ||
Mercury relay unit | Model: 04-00014A | Model: 04-00015A |