This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

Compact and Lightweight
Portable vibration analyzer for equipment diagnosis and on-site measurements.
Vibration meter with FFT analysis function.
Vibration Analyzer
Model:
VA-12
Maker:
RION CO.,LTD.
Features
- Vibration meter mode: Allows simultaneous measurement of acceleration, velocity, displacement, and acceleration crest factor.
- FFT analyzer mode: Real-time analysis frequency 20 kHz, 3 200 spectral lines and available Envelope processing.
- Waveform data storing on SD card for post process/analysis.
- Option: Waveform analysis software, Comparator software
VA-12: Vibration Analyzer
Specifications
Standard compliance | CE marking, Chinese RoHS (export model for China only), WEEE Directive |
|||
Input section | Number of measurement channels | 1 | ||
Connector type etc. | BNC, CCLD 18 V 2 mA, (CCLD24 V 4 mA available as factory option) | |||
Sensor | Piezoelectric Accelerometer PV-57エ (supplied) | |||
Input range | At sensitivity 0.100 to 0.999 mV/(m/s2) | ACC (Acceleration) | 10, 31.6, 100, 316, 1 000, 3 160, 10 000 m/s2 (rms) | |
VEL (Velocity) | 31.6, 100, 316, 1 000, 3 160, 10 000, 31 600 mm/s (rms) | |||
DISP (Displacement) | 0.89, 2.83, 8.94, 28.3, 89.4, 283, 894 mm (EQp-p) | |||
At sensitivity 1.00 to 9.99 mV/(m/s2), using PV-57エ | ACC (Acceleration) | 1, 3.16, 10, 31.6, 100, 316, 1 000 m/s2 (rms) | ||
VEL (Velocity) | 3.16, 10, 31.6, 100, 316, 1 000, 3 160 mm/s (rms) | |||
DISP (Displacement) | 0.089, 0.283, 0.894, 2.83, 8.94, 28.3, 89.4 mm (EQp-p) | |||
At sensitivity 10.0 to 99.9 mV/(m/s2) | ACC (Acceleration) | 0.1, 0.316, 1, 3.16, 10, 31.6, 100 m/s2 (rms) | ||
VEL (Velocity) | 0.316, 1, 3.16, 10, 31.6, 100, 316 mm/s (rms) | |||
DISP (Displacement) | 0.0089, 0.0283, 0.0894, 0.283, 0.894, 2.83, 8.94 mm (EQp-p) | |||
Measurement range (using PV-57エ, High-pass filter 3 Hz, Low-pass filter 20 kHz) | ACC (Acceleration) | 0.02 to 141.4 m/s2 (rms) Continuous measurement, 1 Hz to 5 kHz | ||
Instantaneous maximum acceleration | 700 m/s2 | |||
VEL (Velocity) | 0.2 to 141.4 mm/s (rms) at 159.15 Hz | |||
DISP (Displacement) | 0.02 to 40.0 mm (EQp-p) at 15.915 Hz | |||
Measurement frequency range (electrical characteristics) | ACC (Acceleration) | 1 Hz to 20 kHz | ||
VEL (Velocity) | 3 Hz to 3 kHz | |||
DISP (Displacement) | 3 Hz to 500 Hz | |||
Acceleration envelope curve | 1 kHz to 20 kHz | |||
Filters | Prefilters | High-pass filter | 1 Hz (acceleration only), 3 Hz, 10 Hz, 1 kHz (-10 % point), cutoff slope -18 dB/oct | |
Low-pass filter | 1 kHz, 5 kHz, 20 kHz (-10 % point), cutoff slope -18 dB/oct | |||
Acceleration envelope curve filter | High-pass filter | 1 kHz (-10 % point), cutoff slope -18 dB/oct | ||
Inherent noise | High-pass filter 3 Hz, Low-pass filter 20 kHz, lowest range setting | |||
ACC (Acceleration) | 0.01 m/s2 (rms) or less | |||
VEL (Velocity) | 0.1 mm/s (rms) or less | |||
DISP (Displacement) | 0.01 mm (EQp-p) or less | |||
A/D conversion | 24 bit △Σprinciple, 51.2 kHz | |||
Dynamic range | Maximum 110 dB (Acceleration) | |||
Vibration meter mode | ACC (Acceleration) | m/s2 rms value, waveform peak value, crest factor | ||
VEL (Velocity) | mm/s rms value | |||
DISP (Displacement) | mm EQp-p | |||
FFT mode | Time waveform, spectrum, Acceleration envelope curve | |||
Analysis points | 512, 1 024, 2 048, 4 096, 8 192 (3 200 lines) | |||
Time window functions | Rectangular, Hanning, flat-top | |||
Processing | Linear average, maximum, exponential averaging, instantaneous value | |||
Frequency span | 100 Hz, 200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz, 20 kHz | |||
Display | Spectrum | Top 10 list, graph display (excluding DC) | ||
Zoom | X axis : x1, x2, x4, x8, x16 | |||
Y axis : 2N, N = 0 to 10 (x1 to x1024) | ||||
Overlay display with stored data in spectrum mode | ||||
Time wave form | Graph display | |||
Zoom | X axis : x1, x2, x4, x8, x16, x32 | |||
Y axis : 2N, N = 0 to 14 (x1 to x16 384) | ||||
Trigger | Trigger source | External signal | Triggered at falling edge of signal at external trigger input | |
Input level | Triggered when time waveform crosses a preset level Trigger level can be set in steps of 1/8 of full scale on one-sided amplitude |
|||
Slope | +/- trigger operation | |||
Trigger operation | Free-run | Processing always carried out, regardless of trigger condition | ||
Repeat | Processing carried out whenever triggering occurs | |||
Single | Processing carried out once only when triggering occurs | |||
Time | Data are stored according to the setting of Trigger Start Time, Store Interval, Store number. |
|||
Pretrigger | Processing starts from data 1/8 frame time ahead | |||
Display | Color TFT LCD, 240 x 320 dots, with backlight Japanese display, English display, Time display |
|||
Warning indication | LED (lights up in red to indicate overload) | |||
Memory | Memory media | SD cards (max. 2 GB)* | ||
Store files | Sets of measurement values and parameters can be stored on memory card 1 000 data saved as one store name. Max. number of store names: 100 |
|||
Parameter setting memory | Up to 5 parameter sets can be stored in unit Parameter settings can be stored on memory card |
|||
Wave files | Up to 10 seconds per file (frequency range 20 kHz) Vibration waveform recorded during FFT processing available when using a computer. | |||
BMP files | Screen capture can be saved as BMP files. | |||
Recall function | Measurement data can be read from memory card and redisplayed on screen. | |||
Resume function | Settings are memorized when power is turned off and can be restored at next power-on | |||
Input/output section | Trigger input connector | TTL level, BNC-mini plug, 2.5 mm dia. (for CC-24) | ||
USB port | Removable disk function | Allows use of memory card inserted in unit as removable storage device (removable storage device class) | ||
Power | DC12 V (11 to 15 V) | AC adapter NC-99, eight IEC R6 (size AA) batteries (23℃, normal operation, backlight off) |
||
Battery life | Approx. 12 hours | |||
Current consumption | 145 mA (normal operation, backlight off) | |||
Power consumption (primary side) |
Approx. 10 VA (in case of AC 100 V (NC-99) ) | |||
Ambient temperature and humidity conditions for use | Accelerometer | -20 °C to +70 °C, 90 % RH or less | ||
Main unit | -10 °C to +50 °C, 90 % RH or less (no condensation) | |||
Dimensions, Weight | 213 (H) x 105 (W) x 36 (D) mm; Mass Approx. 850 g (incl. batteries, with protective cover, PV-57エ connected) |
|||
Supplied accessories | Piezoelectric Accelerometer PV-57エ, Curled cable, Magnet attachment IEC R6 (size AA) battery x 8, SD card, Protective cover, Shoulder belt |