This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

Increase the reliability of insulation resistance testing in battery production processes
Key Features
• Detect minuscule short-circuits caused by contamination before batteries are shipped.
• Deliver reliable test results, even in noisy environments.
• Its contact check function reduces the number of false negatives caused by equipment issues.
• High-speed testing makes it possible to increase production volume
• A compact footprint makes it easy to integrate the BT5525 into existing systems and allows new instruments to be added in a space-saving manner.
Battery Insulation Tester
Model:
BT5525
Maker:
Hioki
Introduction and Application
Specifications
Main functions | Insulation resistance test Break Down Detect function (BDD) Contact check function |
Output specifications | Output voltage : 25 V to 500 V, Setting resolution 1 V Charging current (Current limit function) : 50 µA to 50 mA*1*2*3, Minimum setting resolution 10 μA Short-circuit current : 60 mA or less Discharge current : 40 mA or greater*1: Constraints involving the output generator will result in an error, making measurement impossible, if a capacitive load of approximately 50 μF or greater is connected while using a current limit setting of 5.1 mA or greater. *2: When using a current limit setting of 5.1 mA or greater, measurement will be forcibly stopped if the output voltage is not at least 20 V at 200 ms after the start of measurement. Measurement will be possible 1 s after forcibly stopped. *3: If the set current limit value is from 5.1 mA to 50.0 mA, the current will be limited to 5 mA after the output voltage reaches the set voltage. |
Measurement specifications | Resistance value display range : 0.050 MΩ to 9999 MΩ Resistance range : 2 MΩ, 20 MΩ, 200 MΩ, 2000 MΩ, AUTO |
Basic specifications | ±1.5% rdg.±2 dgt. 25 V ≦ V < 100 V [0.05 MΩ 〜 2 MΩ], 100 V ≦ V ≦ 500 V [0.2 MΩ 〜 20 MΩ] |
Time specifications | Test time : 0.050 s to 999.999 s, OFF Comparator delay time : 0.001 s to 999.999 s, AUTO Display update speed : 1 PLC Sampling time : 1 PLC to 100 PLC |
Memory functions | Panel save function : Saves up to 15 sets of measurement conditions Measured value memory function : Saves up to 999 measured values in the instrument’s internal memory |
Judgment functions | Test modes : Continuous test, PASS STOP, FAIL STOP Comparator function : UPPER_FAIL : Measured value > upper limit value PASS : Upper limit value ≥ measured value ≥ lower limit value LOWER_FAIL : Measured value < lower limit value |
Various functions | Break Down Detect function (BDD) : Detecting minuscule insulation defects caused by contamination Contact check function : 2-terminal capacitance measurement method Automatic data output function : Automatic output of measurement results via communication interface after completion of test Command monitor function : Screen display of commands being sent and received External I/O monitor function : Screen display of output signal ON/OFF and input signal status Analog output function : Converts measured values to 0 to 4 V DC and outputs |
Interfaces | USB, LAN, RS-232C, EXT. I/O |
Power Supply | 100 V to 240 V AC |
Power consumption | Approx. 20 VA*4
*4: Power supply conditions are 220 V supply voltage, 50, 60 Hz supply frequency, 200 V test voltage, 2 mA current limit, and load (1 GΩ resistor and 0.1 μF capacitor connected in parallel). |
Maximum rated power | 100 VA |
Dimensions and mass | Approx. 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D (excluding protruding parts), Approx. 2.8 kg (98.8 oz) |
Included accessories | Power cord ×1, EXT. I/O male connector ×1, EXT. I/O connector cover ×1, EXT. I/O interlock cancellation jig ×1, Startup Guide ×1 |