NF Bipolar DC Power Supply BP series

Wide output range, variety of application. For various automotive components, motor, solenoid, capacitor and others

BP series is a high voltage, large current, high speed bipolar power supply with built-in sequence function. In addition to a bipolar output that allows plus, minus, source, and sink, it has a sequence function that can freely program the output pattern.

Bipolar DC Power Supply BP series

Model:

BP4610(±10 A), BP4620(±20 A), BP4630(±30 A), BP4640(±40 A), BP4650(±50 A), BP4660(±60 A), BP4670(±70 A), BP4680(±80 A), BP4690(±90 A), BP46100(±100 A)

Maker:

NF Corporation

Download Materials

Features

  • Wide range voltage output ±60 V (120 Vp-p)
    (Voltage level shift is possible: Output voltage up to +115 V)
  • 10 models, ±10 A to ±100 A
  • Wide bandwidth: DC to 150 kHz (CV mode)
  • Fast response: Rise / Fall time 2.5 µs (CV mode)
  • Four-quadrant operation: Source and sink are possible
  • Up to 255-step sequence function
  • DC, sine wave, square wave, and arbitrary waveforms
  • Selectable constant voltage (CV) and constant current (CC) modes
  • Response calibration function
  • Voltage / Current limiter and measurement function
  • USB and external control I/O
  • Analog input operation as a power amplifier
  • Bundled control software (data logging, sequence editing, arbitrary waveform editing)
  • Power input: Three-phase 3-wire or three-phase 4-wire
    (specify when ordering, BP4640 to BP46100)

Examples of use

  • As an ISO 16750-2:2006 standard compliance test equipment
    Using BP series with multi function generator WF1973/WF1974, You can conduct an ISO 16750-2:2006 standard compliance test.
  • As a constant current power supply for generating magnetic field
    In electromagnetic field test, constant current needs to be supplied to the coil for stable generation of constant magnetic field.
  • As a constant current power supply for capacitor ripple test
    Using this power supply, you can perform ripple test on the units using capacitor(s) such as inverters.

Line up

BP4610 BP4620 BP4630 BP4640 BP4650 BP4660 BP4670 BP4680 BP4690 BP46100
Voltage ± 60 V, 120 Vp-p
By the limiter setting, the output range can be shifted to – 5 V to + 115 V and – 115 V to + 5 V (Output current range changes)
Current (DC) ±10A ±20A ±30A ±40A ±50A ±60A ±70A ±80A ±90A ±100A
Current (AC) ±15A ±30A ±45A ±60A ±75A ±90A ±105A ±120A ±135A ±150A
Low amplitude frequency response DC to 200 kHz (CV, adjusted, amplitude 12 Vp-p)
DC to 70 kHz (CC, adjusted, amplitude 12 Vp-p)
DC to 170 kHz (CV, adjusted, amplitude 12 Vp-p)
DC to 70 kHz (CC, adjusted, amplitude 12 Vp-p)