CONTENTS CONTENTS

ITEMLIST

Products Infomation

KIKUSUI Bidirectional High-Capacity DC Power Supply PXB Series

For the Progressive “ X” electric applications

The PXB series of bidirectional high-capacity DC power supplies condenses a 20 kW large-capacity output into a 3U-size chassis. Not only handling high voltages of 1500 V, but also capable of both power and regeneration in both directions in a single unit. We provide a new power supply test environment for electrical and electronic equipment that is becoming increasingly high-powered. In addition, a variety of analog, digital, and communication interfaces are provided for optimal operation at any stage of research, development, and manufacturing! A new generation of bidirectional DC power supplies that support the progression of advanced technologies.

Bidirectional High-Capacity DC Power Supply

Model:

PXB Series

Maker:

KIKUSUI ELECTRONICS CORPORATION

Features

  • High power density: 20 kW in 3U size
  • A single unit handles both power and regeneration
  • Rated output voltage 50 V/ 250 V/ 500 V/ 1000 V/ 1500 V
  • Select a model with an input voltage from 200 Vac (3-phase) or 400 Vac (3-phase)
  • Continuous operation at rated power at ambient temperature of 50°C (Excluding some models)
  • Up to 10 units (200 kW) can be operated in parallel
  • Equipped with touch panel display
  • LAN, USB, RS232C, external analog control (isolated type) standard
  • Regenerative function (on-site)
  • External control I/O is standard for both NPN and PNP type PLCs

Specifications

Output rating

Item PXB20K-50 PXB20K-250 PXB20K-500 PXB20K-1000 PXB20K-1500
Rated power ±20000 W ±20000 W ±20000 W ±20000 W ±20000 W
Rated voltage (source) *1 0 V to 50 V 0 V to 250 V 0 V to 500 V 0 V to 1000 V 0 V to 1500 V
Operating voltage (sink) *2 3 V to 50 V 15 V to 250 V 10 V to 500 V 20 V to 1000 V 30 V to 1500 V
Rated current *1 ±800 A ±200 A ±120 A ±60 A ±30 A

*1. Limited by the maximum output power. *2. Operating voltage at which the rated sink current can be applied.

 

Output voltage

Item PXB20K-50 PXB20K-250 PXB20K-500 PXB20K-1000 PXB20K-1500
Maximum settable voltage 52.5 V 262.5 V 525 V 1050 V 1575 V
Setting accuracy ±(0.2 % of setting + 0.1 % of rating)
Resolution 0.005 V 0.02 V 0.05 V 0.1 V 0.1 V
Power fluctuation*1 ±10 mV ±50 mV ±100 mV ±200 mV ±300 mV
Load variation *2 ±40 mV ±125 mV ±250 mV ±500 mV ±750 mV
Remote sensing Maximum compensation voltage (reciprocating) 10 % of rating
Internal resistance setting upper limit 63 mΩ 1575 mΩ 5250 mΩ 21000 mΩ 63000 mΩ
Internal resistance setting resolution 1 mΩ 1 mΩ 1 mΩ 2 mΩ 5 mΩ
Response switching FAST, SLOW
Slew rate switching (TYP) 12.5 V/ms or more *3 62.5 V/ms or more *3 125 V/ms or more *3 250 V/ms or more *3 375 V/ms or more *3
12.5 V/ms 62.5 V/ms 125 V/ms 250 V/ms 375 V/ms
1.25 V/ms 6.25 V/ms 12.5 V/ms 25.0 V/ms 37.5 V/ms
0.125 V/ms 0.625 V/ms 1.25 V/ms 2.50 V/ms 3.75 V/ms
0.0125 V/ms 0.0625 V/ms 0.125 V/ms 0.250 V/ms 0.375 V/ms
Source only *4 Transient response *5 8 ms or less 8 ms or less 8 ms or less 10 ms 以下 10 ms 以下
Ripple noise *6 p-p*7 250 mV 375 mV 1000 mV 1500 mV 2500 mV
rms*8 30 mV 125 mV 250 mV 500 mV 750 mV
Rise time *9 Full load *10 10 ms
No load 10 ms
Fall time *11 Full load *10 10 ms
No load 10 ms

*1. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load.
*2. The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point.
*3. MAX will appear on the display.
*4. In the case that the CV mode response setting is set to FAST.
*5. The amount of time required for the output voltage to return to a value within “rated output voltage ±(0.1 % + 10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage.
*6. At the rated output current. Values measured using JEITA RC-9131C probe and 100:1 probe.
*7. Measurement frequency band: 10 Hz to 20 MHz
*8. Measurement frequency band: 10 Hz to 1 MHz
*9. 10 % to 90 % of the rated output voltage.
*10.For a pure resistance.
*11. 90 % to 10 % of the rated output voltage.

 

Output current

Item PXB20K-50 PXB20K-250 PXB20K-500 PXB20K-1000 PXB20K-1500
Settable maximum source current *1 +840 A +210 A +126 A +63 A +31.5 A
Settable maximum sink current *1 -840 A -210 A -126 A -63 A -31.5 A
Seamless setting current range *1 -840 A to +840 A -210 A to +210 A -126 A to +126 A -63 A to +63 A -31.5 A to +31.5 A
Setting accuracy ±(0.75 % of rating)
Resolution 0.1 A 0.02 A 0.01 A 0.005 A 0.002 A
Line regulation ±1600 mA ±400 mA ±240 mA ±120 mA ±60 mA
Load regulation ±1600 mA ±400 mA ±240 mA ±120 mA ±60 mA
Rise time (Short-circuit) (TYP) *2 5 ms
Fall time (Short-circuit) (TYP) *3 5 ms
Charge/discharge switching time (TYP) 10 ms
Response switching FAST, SLOW
Slew rate switching (TYP) *4 200 A/ms or more *3 50 A/ms or more *3 30 A/ms or more *3 15 A/ms or more *3 7.5 A/ms or more *3
200 A/ms 50 A/ms 30 A/ms 15 A/ms 7.5 A/ms
20 A/ms 5 A/ms 3 A/ms 1.5 A/ms 0.75 A/ms
2 A/ms 0.5 A/ms 0.3 A/ms 0.15 A/ms 0.075 A/ms
0.2 A/ms 0.05 A/ms 0.03 A/ms 0.015 A/ms 0.0075 A/ms

*1. During parallel operation, this will be the value multiplied by the number of units in the configuration.
*2. In the case that the CC mode response setting is set to FAST: Applied in response to changes from 10 % to 90 % of rated output current.
*3. In the case that the CC mode response setting is set to FAST: Applied in response to changes from 90 % to 10 % of rated output current.
*4. MAX will appear on the display.

 

Output power

Item Common to all models
Settable maximum source power +21000 W
Settable maximum sink power -21000 W
Seamless setting power range -21000 W to +21000 W
Setting accuracy *1 ±(0.5 % of power rating + 0.5 % of current rating × Vout)
Resolution 2 W

*1. Equal to or higher than 5 % of the rated power is guaranteed. Less than 5 % of the rated power is guaranteed as a TYP value.

 

General specifications

Item PXB20K-50 PXB20K-250 PXB20K-500 PXB20K-1000 PXB20K-1500
Weight Approx. 41 kg Approx. 39 kg Approx. 38 kg Approx. 37 kg Approx. 37 kg
Dimensions Refer to Outline Drawing
Environmental conditions Operating environment Indoor use, overvoltage category II
Operating temperature 0 ℃ to +40 ℃ 0 °C to +50 °C (32 °F to +122 °F)
Operating humidity 20 %rh to 85 %rh (non-condensing)
Storage temperature -25 °C to +60 °C (-13 °F to 140 °F)
Storage humidity 90 %rh or less (non-condensing)
Altitude Up to 2000 m
Cooling method Forced air cooling using fan
Accessories AC INPUT terminal cover, connector kit for external control (1 set), chassis connection wire, DC OUTPUT terminal cover, screws for DC OUTPUT terminal (1 set), EXT SYNC connector cover, SENSING terminal cover, SENSING connector (2 pieces), synchronous operation signal cable kit, For Safety (1 copy), China RoHS sheet (1 sheet), start guide (1 copy), heavy object warning seal (1 sheet)
Withstanding voltage Between input and GND 2200 Vac, 1 minute
Between input and output
Between output and GND 500 Vdc, 1 minute 1000 Vdc, 1 minute 1800 Vdc, 1 minute 1800 Vdc, 1 minute 3000 Vdc, 1 minute
Insulation resistance Between input and GND 30 MΩ, 500 Vdc
Between input and output 30 MΩ, 500 Vdc 30 MΩ, 600 Vdc 30 MΩ, 1000 Vdc
Isolation voltage ± 250 V ± 600 V ± 1000 V ± 1000 V +2000 V/-1000 V
Electromagnetic compatibility *1 *2 Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A *3)
Safety *1 Complies with the requirements of the following directive and standards.
Low Voltage Directive 2014/35/EU *2
EN 61010-1 (Class I *4, Overvoltage category II, Pollution degree 2 *5)
UL 61010-1 *6 CAN/CSA -C 22.2 NO.61010-1 *6

*1. Does not apply to specially ordered or modified products.
*2. Only for models with CE marking / UKCA marking on their body.
*3. This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided
unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4. This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*5. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive
pollution will occur except for an occasional temporary conductivity caused by condensation.
*6. Only on models that have cTUVus marking on the panel.

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.