This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Compact but realizing efficient environmental for testing with high-performance networking
Of a bench-top size that can fit on a personal desk, this small temperature and humidity chamber achieves high performance to fulfill your environmental testing needs.
The lineup including 12 models available in two sizes (22.5L and 64L) with a temperature range of -20, -40, or -60 °C to +150 °C for temperature tests or climate tests allow you to choose the performance best suited for your test applications.
In addition, the model with temperature change rate of 5K/min can meet requirement for fast cycling test from various industries.
Featuring a touch screen color display for easy operation, the controller carries the same function and design of the Platinous J chambers.
Compact Environmental Tester
Model:
SU-662
Maker:
ESPEC CORP.
Features
Compact enough for desktops
Stackable for enhanced space efficiency
Caster-equipped stands are easy to move and are available in low types (C stand/L stand), H stand for storing these low types underneath, and M stand that comes in the same height as commonly used office desks.
Instrumentation Interlock I/O Terminals
Chamber comes with instrumentation interlock I/O terminals as a standard, which allow the chamber to work in synchronization with measuring instruments.
Using an input terminal enables chamberspecified program patterns to be run or stopped depending on measuring instrument operation.
Three-way access
Chamber comes with a cp50mm cable port on the right side as a standard, but you can enlarge and or add more cable ports on the right, left and the top.
Line up
| Model | Power Supply | Temperature & Humidity range | Inside/Outside dimensions(mm) |
|---|---|---|---|
| SH-222 |
100V AC 50/60Hz 115V AC 60Hz NEC 220V AC 50/60Hz * 230V AC 50Hz * |
-20 to +150℃ 30 to 95%rh |
W300×H300×D250 |
| SH-242 |
-40 to +150℃ 30 to 95%rh | ||
| SH-262 |
100V /200V AC 50/60Hz 220V AC 50/60Hz * 230V AC 50Hz * 200V AC 50/60Hz NEC |
-60 to +150℃ 30 to 95%rh |
W300×H300×D250 |
| SH-642 |
-40 to +150℃ 30 to 95%rh |
W400×H400×D400 | |
| SH-662 |
-60 to +150℃ 30 to 95%rh |
||
| SH-242-5 Temperature rate of change:5℃/min |
100V /200V AC 50/60Hz 220V AC 50/60Hz * 230V AC 50Hz * |
-40 to +150℃ 30 to 95%rh |
W300×H300×D250 |
* Compliance with CE marking.
Specifications
| SU−662 | |||
| System | Balanced Temperature Control system (BTC system) | ||
| Temp. performance*1 | |||
| Temp. range | −60 to +150°C (−76 to +302°F) | ||
| Temp. fluctuation | ±0.3°C (−60 to +100°C) ±0.5°C (+100.1 to +150°C) | ||
| Temp. variation in space | 2.5°C (−60 to +100°C) 4.0°C (+100.1 to +150°C) | ||
| Temp. rate of change | Heat up rate | 2.9°C/min | |
| Pull down rate | 1.7°C/min | ||
| Temp. extreme achievement time Heat up time | From −60 to +150°C within 80 min. | ||
| Temp. extreme achievement time Pull down time | From +20 to −60°C within 90 min. | ||
| Lowest attainable temp. | −60°C | ||
| Construction | |||
| Heater | Nichrome strip wire heater | ||
| Refrigeration unit | System | Mechanical cascade refrigeration system | |
| Cooler | Plate fin cooler | ||
| Refrigerator | Hermetically sealed compressor, Air-cooled condenser, Expansion mechanism: Capillary tube system | ||
| Refrigerator capacity | 400W [Unit 1: 400W × 1, unit 2: 400W × 1] | ||
| Refrigerant | R-404A, R-23 | ||
| Capacity | 64 L | ||
| Chamber total load resistance | 20 kg | ||
| Inside dimensions mm (inch) *2 | W400×H400×D400 (W15.7 × H15.7 × D15.7) | ||
| Outside dimensions mm (inch) *2 | W540×H665×D921 (W21.2 × H26.1 × D36.2) | ||
| Weight | 123 kg | ||
| Utility requiremnets | |||
| Allowable ambient conditions | +5 to +35°C (+41 to +95°F) | ||
| Power supply *3 | |||
| 100V AC 1φ50/60Hz | 17.5 A | ||
| 115V AC 1φ60Hz (NEC) | — | ||
| 200V AC 1φ50/60Hz *4 | 14.5 A | ||
| 220V AC 1φ50/60Hz *5 | 14.0 A | ||
| 230V AC 1φ50Hz *5 | 14.0 A | ||
| Noise level *6 | Between 48 and 53 dB | ||
| Exhaust heat quantity | 5040 kJ/h | ||
*1 The performance values are based on IEC 60068-3-5:2001 for the temperature chamber.
Performance figures are given for a +23°C ambient temperature, 65%rh, rated power supply and no specimens inside the test area. However, the lowest attainable temperature is given for a max. ambient temperature of +30°C. Heat-up time is the achieved time from lowest temperature to highest temperature within temperature range.
*2 Excluding protrusions.
*3 At ambient temperature +23°C.
*4 200V AC available with or without NEC specifications. SU-242-5 not available with NEC specification.
*5 Compliance with CE marking.
*6 Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level)