NOISEKEN Electrostatic Discharge Simulator ESS-B3011A/GT-30RA/GT-30R3302KA | NIHON DENKEI PHILIPPINES, Inc.
CONTENTS CONTENTS

ITEMLIST

Products Infomation

NOISEKEN Electrostatic Discharge Simulator ESS-B3011A/GT-30RA/GT-30R3302KA

EN/IEC 61000-4-2 Ed2 & ISO 10605 Ed2 Compliant Cost-oriented Basic ESD simulator

“NoiseKen” ESD simulators can reproduce and simulate the ESD from a charged human body intentionally for testing whether electronic equipments become malfunctioned or work correctly with the ESD influence, and the simulators conform to IEC61000-4-2 Standard which is standardized by International Electrotechnical Committee (IEC).

Electrostatic Discharge Simulator

Model:

ESS-B3011A & GT-30RA / GT-30R3302KA

Maker:

NOISE LABORATORY CO.,LTD.

Features

  • EN/IEC 61000-4-2 Ed2 Compliant (B3011A)
  • ISO 10605 Ed2 Compliant (B3011A) (Note: Optional gun head and CR units are required.)
  • “Discharge detecting function” to realize the air-discharge confirmation (B3011A)
  • “Lightest Discharge Gun in the market “to lighten the continuous operation (GT-30RA)
  • “White LED Irradiator” to facilitate the visualization of the discharging point (GT-30RA)

SPECIFICATIONS

 

■ SPECIFICATIONS ESS-B3011A ■ 

Items ESS-B3011A specifications
Polarity Positive or Negative
Output voltage 0.2 to 30.0kV +/-5%
(30.5kV maximum)
0.2 to 10kV: 0.05kV step
10.0 to 30.5kV: 0.10kV step
Repetition cycle 0.05 to 99.9s (+/- 10%) /Manual
0.05 to 10.0s: 0.05s step
10.0 to 99.9s: 0.10s step
No. of time of discharge 1 to 999 times /continuous
Discharge mode Contact discharge/ Air discharge
Trigger mode Gun trigger / Main unit trigger
Operation panel Indicator: 5×7 dot matrix LED
Operation: Push-buttons (Partially lighting)
Radiation mode select switch Extra / Normal switching function built-in
Discharge detection Discharge detection function in air-discharge mode
Pre-checking function High voltage output checking
(by user operation.  Not the calibration but just checking)
CR & Gun head checking CR constant and gun head recognizable
(with an indicator to prevent the wrong combination)
IEC level switching function Contact discharge mode: 2.0, 4.0, 6.0, 8.0 kV step
Air discharge mode: 2.0, 4.0, 8.0, 15.0 kV step
Warning lamp Lights up while the HV circuitry is on.
Blinks while discharges are in progress.
Charging capacitor and resistance 150pF+/-10%, 330 ohm +/-10%
(built into Discharge Gun GT-30RA)
Main unit charging resistance 10M ohm
(53Mohm for combination with Discharge Gun GT-30RA)
Power supply/ Power consumption 100 to 240V AC  50/60 Hz +/-10%  62VA
Included accessories Instruction manual
Dimensions and weight (W)270 X (H)263 X (D)200 mm (projection excluded)
Approx. 4.6 kg

 

■ Discharge Gun GT-30RA Conforming to IEC 61000-4-2

Items Specifications
Output voltage 0.20~30.0kV ±5% (with ESS-S3011A/B3011A)
0.20~16.0kV ±5% (with ESS-L1611A)
Discharge mode Air discharge and contact discharge
Discharge waveform parameters Compliant with EN/IEC61000-4-2
Standard energy storage capacitor 150 PF±10%
Standard discharge resistor 330ohm±10%
Charging resistor 43Mohm
(53M ohm for combination with ESS main unit)
Cable length 2 m
Dimensions 83.4(W) x 217.2(H) x 189.3 (D) mm
(Discharge tip excluded)
Weight Approx. 1300g  (cable and high voltage connector included

 

■ Discharge Gun GT-30R3302KA Conforming to ISO10605

Items GT-30R3302KA
Output voltage 0.20~30.0kV ±5% (with ESS-S3011A/B3011A)
0.20~16.0kV ±5% (with ESS-L1611A)
Discharge mode Air discharge and contact discharge
Output polarity Positive / negative
Standard energy storage capacitor 150 PF±10% , 330 PF ±10%
Standard discharge resistor 330 ohm±10% & 2K ohm ±10%
Charging resistor Contained in the CR unit
Cable length 2 m
Charged voltage hold time 5 seconds or more
Dimensions 83.3(W) x 217.2(H) x 229.3 (D) mm
(Discharge tip excluded)
Weight Approx. 1300g  (cable and high voltage connector included)

 

 

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.