This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

EN/IEC 61000-4-2 Ed2 & ISO 10605 Ed2 Compliant Cost-oriented Basic ESD simulator
“NoiseKen” ESD simulators can reproduce and simulate the ESD from a charged human body intentionally for testing whether electronic equipments become malfunctioned or work correctly with the ESD influence, and the simulators conform to IEC61000-4-2 Standard which is standardized by International Electrotechnical Committee (IEC).
Electrostatic Discharge Simulator
Model:
ESS-B3011A & GT-30RA / GT-30R3302KA
Maker:
NOISE LABORATORY CO.,LTD.
Features
- EN/IEC 61000-4-2 Ed2 Compliant (B3011A)
- ISO 10605 Ed2 Compliant (B3011A) (Note: Optional gun head and CR units are required.)
- “Discharge detecting function” to realize the air-discharge confirmation (B3011A)
- “Lightest Discharge Gun in the market “to lighten the continuous operation (GT-30RA)
- “White LED Irradiator” to facilitate the visualization of the discharging point (GT-30RA)
SPECIFICATIONS
■ SPECIFICATIONS ESS-B3011A ■
Items | ESS-B3011A specifications |
Polarity | Positive or Negative |
Output voltage | 0.2 to 30.0kV +/-5% (30.5kV maximum) 0.2 to 10kV: 0.05kV step 10.0 to 30.5kV: 0.10kV step |
Repetition cycle | 0.05 to 99.9s (+/- 10%) /Manual 0.05 to 10.0s: 0.05s step 10.0 to 99.9s: 0.10s step |
No. of time of discharge | 1 to 999 times /continuous |
Discharge mode | Contact discharge/ Air discharge |
Trigger mode | Gun trigger / Main unit trigger |
Operation panel | Indicator: 5×7 dot matrix LED Operation: Push-buttons (Partially lighting) |
Radiation mode select switch | Extra / Normal switching function built-in |
Discharge detection | Discharge detection function in air-discharge mode |
Pre-checking function | High voltage output checking (by user operation. Not the calibration but just checking) |
CR & Gun head checking | CR constant and gun head recognizable (with an indicator to prevent the wrong combination) |
IEC level switching function | Contact discharge mode: 2.0, 4.0, 6.0, 8.0 kV step Air discharge mode: 2.0, 4.0, 8.0, 15.0 kV step |
Warning lamp | Lights up while the HV circuitry is on. Blinks while discharges are in progress. |
Charging capacitor and resistance | 150pF+/-10%, 330 ohm +/-10% (built into Discharge Gun GT-30RA) |
Main unit charging resistance | 10M ohm (53Mohm for combination with Discharge Gun GT-30RA) |
Power supply/ Power consumption | 100 to 240V AC 50/60 Hz +/-10% 62VA |
Included accessories | Instruction manual |
Dimensions and weight | (W)270 X (H)263 X (D)200 mm (projection excluded) Approx. 4.6 kg |
■ Discharge Gun GT-30RA Conforming to IEC 61000-4-2■
Items | Specifications |
Output voltage | 0.20~30.0kV ±5% (with ESS-S3011A/B3011A) 0.20~16.0kV ±5% (with ESS-L1611A) |
Discharge mode | Air discharge and contact discharge |
Discharge waveform parameters | Compliant with EN/IEC61000-4-2 |
Standard energy storage capacitor | 150 PF±10% |
Standard discharge resistor | 330ohm±10% |
Charging resistor | 43Mohm (53M ohm for combination with ESS main unit) |
Cable length | 2 m |
Dimensions | 83.4(W) x 217.2(H) x 189.3 (D) mm (Discharge tip excluded) |
Weight | Approx. 1300g (cable and high voltage connector included |
■ Discharge Gun GT-30R3302KA Conforming to ISO10605■
Items | GT-30R3302KA |
Output voltage | 0.20~30.0kV ±5% (with ESS-S3011A/B3011A) 0.20~16.0kV ±5% (with ESS-L1611A) |
Discharge mode | Air discharge and contact discharge |
Output polarity | Positive / negative |
Standard energy storage capacitor | 150 PF±10% , 330 PF ±10% |
Standard discharge resistor | 330 ohm±10% & 2K ohm ±10% |
Charging resistor | Contained in the CR unit |
Cable length | 2 m |
Charged voltage hold time | 5 seconds or more |
Dimensions | 83.3(W) x 217.2(H) x 229.3 (D) mm (Discharge tip excluded) |