This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Complying with various safety standards for general electrical equipment, this tester is used for touch current and protective conductor current tests
The TOS3200 is designed to test for leakage current (Touch Current and Protective Conductor Current) of general electrical apparatuses, excluding those used for medical purposes. With this tester, you can conduct tests conforming to various standards including IEC, UL, JIS and Electrical Appliance and Material Safety Law (Japan). You can set test conditions through simple operations on the panel because this tester holds in its memory the 51 types of test conditions for IT-related electrical equipment, electrical appliances, audio & visual equipment, lighting fixtures, power
tools, and measuring and control instruments, accordingly with the standards of IEC/JIS and Electrical Appliance and Material Safety Law.
Leakage Current Tester
Model:
TOS3200
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
- Measures leakage current in 3 operation modes: Touch Current (TC), Protective Conductor Current (PCC), and METER operation mode
- Eight types of measuring circuit networks are incorporated in the tester for measuring the touch current of general electrical apparatuses
- Possible to measure DC/RMS/PEAK, realizing the “true rootmean-square value” with 30 mA as the maximum RMS
- Easy-to-understand operation
- Possible to choose between Independent and Automatic Testing
- 51 types of preset safety standard tests
- Function for controlling the calibration expiration limits
Specifications
| Measurement terminal | Rated voltage/current | Terminals A to B: 250 V, terminal to chassis: 250 V, 100 mA |
|---|---|---|
| Measurement category | CATⅡ | |
| Valid terminal display | Terminals effective to measurement are indicated with LED lamps. | |
| Environment | Warranty range | Temperature: 5 ̊C to 35 ̊C, humidity: 20% rh to 80% rh (no condensation) |
| Operating range | Temperature: 0 ̊C to 40 ̊C, humidity: 20% rh to 80% rh (no condensation) | |
| Storage range | Temperature: –20 ̊C to 70 ̊C, humidity: 90% rh or less (no condensation) | |
| Installation location | Indoors, altitude of 2000 m or less | |
| AC line power requirements | Input power | Nominal input rating:100Vac to 240Vac, 50/60Hz, power consumption: 70 VA max. |
| for EUT | Nominal input rating:100Vac to 240Vac, 50/60Hz | |
| Rated output capacity: 1500 VA, maximum current: 15 A, rush current: 70 A peak max. (within 20 ms) | ||
| Insulation resistance | 30 MΩ or greater (500 Vdc) (between AC line and chassis, between measurement terminal and chassis) | |
| Withstanding voltage | 1390 Vac, 2 seconds/20 mA or less (between AC line and chassis) | |
| Earth continuity | 25 Aac/0.1 Ω or less | |
| Safety |
Conforms to the requirements of the directive and standard below. |
|
| Electromagnetic compatibility (EMC) *1, *2 | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU, EN 61326-1 (Class A), EN 55011 (Class A, Group 1), EN61000-3-2, EN61000-3-3 Applicable conditions: All cables and wires used to connect to this product must be shorter than 3 meters. Use the supplied test leads. |
|
| Outside dimensions, weight | 320[12.60 inch] (345[13.58 inch]) W × 88[3.46 inch] (105[4.13 inch]) H × 270[10.63 inch] (335[13.19 inch]) D mm, approx. 5 kg(approx. 11.02 lbs) | |
| Accessories | 1 set of test leads (TL21-TOS: red and black, one each, with alligator clips) 1 flat probe (FP01-TOS), 1 spare fuse (15 A, for EUT power) 1 instruction manual, 1 circuit principle diagram sticker 2 power cords (for the tester and for the EUT AC line) | |
The warm-up time must be 30 minutes or longer.rdng denotes a reading, set denotes the set value, and EUT is the electrical equipment under test.
*1: May not apply to custom-made or modified products.
*2: Limited to products with CE marking on their panels.