This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
High-Capacity Wide-Range DC Power Supply PXT Series
The PXT Series high-capacity DC power supply delivers 20 kW in a compact 3U size, with a voltage range of 500V-40A to 166.6V-120A. It's ideal for harsh conditions, operating up to 50°C due to advanced heat dissipation. Featuring low ripple noise and quick transient response, it allows seamless integration with LAN, USB, and RS232C interfaces. Scalable up to 500 kW via parallel operation, the PXT Series is versatile and reliable for demanding electric applications.
It can be used not only as a stand-alone device, but also for integration into test equipment. Furthermore, its excellent heat dissipation design enables it to achieve a guaranteed Operating temperature of 50°C, making it suitable for harsh high-temperature operating environments. The system is also highly scalable, and its capacity can be increased up to 500 kW through Parallel operation (up to 25 units).
High-Capacity Wide-Range DC Power Supply
Model:
PXT Series
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
1.Output power range 2.25 to 3x ratio power type operating
2.Low Ripple Noise
3.Excellent Versatility Thanks to Wide-Range Output
4.Excellent Transient response
5.Optimized for different purposes and applications, with selectable response speeds
6.Equipped with touch panel display
Bleeder ON/OFF Function
By turning on the bleeder function, the charge accumulated on the load side at the time of OUTPUTOFF can be quickly discharged to lower the Output voltage.
A battery connected to the output terminal will be discharged when the bleeder function is on, even if the OUTPUT is turned off. In such cases, unnecessary discharge can be prevented by turning the bleeder function off.
| Item | Description |
| Enable | Turns the bleeder function on. Sink current flows when the output is off. |
| Disable | Disables the bleeder function. Prevents unintended discharge when output is turned off. However, a low sink current will still flow due to the resistance inside the PXT series. The reference values of the internal resistance are as follows: PXT20K-500: approx. 55 kΩ PXT20K-1500: approx. 560 kΩ |
Priority Operation Mode
It is possible to set which Operation mode is used when the output is turned on. When a battery or power supply is connected, overshoot can be prevented by giving priority to CC mode.
Operation modes that can be set: Constant voltage (CV), Constant current (CC), Constant power (CP) mode
Faster no load fall time
The PXT series has a no load fall time of 750 ms. This contributes to shorter takt time.
External Control Function
EXT of rear panel The PXT series can be controlled by external devices using the CONT connector. The general-purpose digital input terminal and the general-purpose digital output terminal can be assigned any functions, facilitating system construction in combination with other measurement devices.
Digital I/O standard for both NPN and PNP type PLCs. Analog I/O is isolated from output terminals as standard, allowing safe analog control from PLC.
Sequence function
Pre-defined actions can be executed continuously. A total of 30 programs can be created, and the Maximum number of steps can be up to 10,000 for all programs. Programs stored in the main unit’s memory can be exported to USB memory from the front panel.
Variable internal resistance feature
This function changes the Output voltage value according to the Output current value based on the set resistance value in constant voltage operation. Internal resistance of rechargeable batteries, wire harnesses, etc. can be simulated in a simplified manner.
I-V characteristic function
By registering multiple arbitrary points on the I-V characteristics, arbitrary I-V characteristics can be set for each CC and CV operation mode. Since 3 to 100 arbitrary points can be registered, it is possible to simulate I-V characteristics of rechargeable batteries, etc.
Parallel operation can realize up to 25 units, 500 kW. *
Up to 25 units (500 kW) can be connected in parallel, including the master unit. The connection is a Master-slave parallel operation, and the panel of the master unit can control and display the entire system. Since it has an automatic recognition function, a large-capacity system can be constructed without complicated settings.
* Parallel operation is possible between models with different input rated voltages.
★ Please consult with us if you would like to use 10 or more units in Parallel operation.
Selectable power input
Full output at rated power regardless of input voltage. Choose from 3-phase 3-wire 200 V or 400 V models. No output limitation for either input voltage.
Reliable and solid performance even under high temperatures
Solid performance under operating temperatures of 0°C to 50°C (32 °F to 122 °F). Full performance even in harsh ambient temperature environments, such as when installed in equipment.
Protection Functions for Safety Operation
- OVP (Over Voltage Protection)
- UVP (Under Voltage Protection)
- WDOG (Communication error protection)
- OPP (Over Power Protection)
- OCP (Over Current Protection)
- EXT LOW (External input alarm detection)
KIKUSUI High-Capacity Wide-Range DC Power Supply PXT Series
Specifications
Analog control/monitoring terminals support various applications.
Remote sensing
These features compensate voltage drops in wires from the output terminals to the load terminals of the PAV series.
Output voltage and output current control using external voltage
It is possible to control the output voltage/output current of the PAV series by using an external voltage.
Output voltage and output current control using external resistance
It is possible to control the output voltage/output current of the PAV series by using an external variable resistor.
Output voltage/current remote monitoring and CV/CC signals
Voltages from 0 V to 5 V or 0 V to 10 V are output proportionally to the output vo
| Specifications | Output | Ripple | Line regulation | Load regulation | Input current | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model | CV | CC | Rated power | CV | CV | CC | CV | CC | AC (200 V 3-phase) / (400 V 3-phase) | Approx. |
| PXT20K-500 3P3W 200V (20kW / 500V / 120A / Input voltage 200V) | 0 to 500 V | 120 A | 20 kW | 100 mVrms | ±100 mV | ±240 mA | ±250 mV | ±240 mA | 80 A | 38 kg (83.78 lbs) |
| PXT20K-500 3P3W 400V (20kW / 500V / 120A / Input voltage 400V) | 0 to 500 V | 120 A | 20 kW | 100 mVrms | ±100 mV | ±240 mA | ±250 mV | ±240 mA | 40 A | 38 kg (83.78 lbs) |
| PXT20K-1000 3P3W (20kW / 1000V / 60A / Input voltage 200V) | 0 to 1000 V | 60 A | 20 kW | 250 mVrms | ±200 mV | ±120 mA | ±750 mV | ±120 mA | 80 A | 38 kg (83.78 lbs) |
| PXT20K-1000 3P3W (20kW / 1000V / 60A / Input voltage 400V) | 0 to 1000 V | 60 A | 20 kW | 250 mVrms | ±200 mV | ±120 mA | ±750 mV | ±120 mA | 40 A | 38 kg (83.78 lbs) |
| PXT20K-1500 3P3W(20kW / 1500V / 30A / Input voltage 200V) | 0 to 1500 V | 30 A | 20 kW | 300 mVrms | ±300 mV | ±60 mA | ±750 mV | ±60 mA | 80 A | 37 kg (81.57 lbs) |
| PXT20K-1500 3P3W(20kW / 1500V / 30A / Input voltage 400V) | 0 to 1500 V | 30 A | 20 kW | 300 mVrms | ±300 mV | ±60 mA | ±750 mV | ±60 mA | 40 A | 37 kg (81.57 lbs) |
ltage/current from the PAV series. The operation state becomes HIGH in CV constant voltage mode and LOW in CC constant current mode.
Output on/off control
It is possible to turn the output ON/OFF of the PAV series by using an external contact.
Series operation
You can connect PAV series with the same rating in series to increase the output voltage. (up to 2 units) Dual output configuration is also supported.
Models whose rated output voltage is 10 V, 20 V or 36 V : ±60 Vdc or less
Models whose rated output voltage is 60 V or 100 V : ±100 Vdc or less
Models whose rated output voltage is 160 V, 320 V, or 650 V : ±650 Vdc or less
Master-slave parallel operation
The PAV series allows up to 6 parallel connections to increase the output current.
Daisy chain connection
A multiple power supply system configured with more than one PAV series allows to create a multi-power supply system that stops all the power supply outputs if any power supply fails.
PS_OK signal
A failure is notified by a TTL level signal if the protection function is activated. The PS_ OK level is HIGH in normal operating state.