This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
High-Capacity Regenerative Electronic Load PXZ Series
The PXZ series of highly efficient, reliable, high-capacity regenerative electronic loads has a rated power of 20 kW in 3U. In addition to the constant-current, constant-resistance, constant-voltage, and constant-power operating modes, this series has an I-V characteristic function that allows the user to set arbitrary I-V characteristics for each CC and CV operating mode. The series is also equipped with various functions, such as sequence, pre-charge, synchronous operation, pulse, sine, and VMCB functions.
LAN, USB, and RS232C communication functions are included as standard, allowing easy integration into various evaluation systems. The PXZ series is highly scalable, and its capacity can be increased up to 500 kW when operating in parallel (up to 25 units).
High-Capacity Regenerative Electronic Load
Model:
PXZ Series
Maker:
KIKUSUI ELECTRONICS CORPORATION
Features
- 20kW rated power in 3U
- Maximum operating voltage of 1500 V
- Operating modes: CC, CR, CV, CP
- Up to 25 units (500 kW) can be operated in parallel
*Please consult with us if you would like to use 10 or more units in Parallel operation. - Equipped with a touch panel display
- Pre-charge function
- I-V characteristic function
- Sequence function
- LAN, USB, RS232C, external analog control (isolated type) as standard
- Regenerative efficiency of over 90% (on-site regeneration)
Line up
| SKU | Output Power [W] | Output CV [V] | Output CC [A] |
|---|---|---|---|
| PXZ20K-50 | 20kW | 3 to 50 | 800 |
| PXZ20K-500 | 10 V to 500 V | 120 | |
| PXZ20K-1000 | 20 to 1000 | 60 | |
| PXZ20K-1500 | 30 V to 1500 V | 30 |
Promotion Videos
Specifications
Rating
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 |
|---|---|---|---|---|
| Rated power | 20000W | |||
| Rated voltage (DC) *1 | 3V to 50V | 10 V to 500V | 20V to 1000V | 30 V to 1500 V |
| Rated current *1 | 800A | 120A | 60A | 30A |
*1 Maximum input current and maximum input voltage are limited by maximum input power.
Constant voltage (CV) mode
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 |
|---|---|---|---|---|
| Maximum settable voltage | 52.5V | 525V | 1050V | 1575V |
| Setting accuracy | ±(0.2 % of setting + 0.1 % of rating) | |||
| Resolution | 0.005V | 0.05V | 0.1V | 0.1V |
| Remote sensing Maximum compensation voltage (reciprocating) (TYP) | 10% of rating | |||
| Response switching | FAST, SLOW | |||
| Slew rate switching (TYP) | 12.5V/ms or more *1 | 125V/ms or more *1 | 250V/ms or more *1 | 375V/ms or more *1 |
| 12.5V/ms | 125V/ms | 250V/ms | 375V/ms | |
| 1.25V/ms | 12.5V/ms | 25V/ms | 37.5V/ms | |
| 0.125V/ms | 1.25V/ms | 2.5V/ms | 3.75V/ms | |
| 0.0125V/ms | 0.125V/ms | 0.25V/ms | 0.375V/ms | |
*1 MAX will appear on the display.
Constant Current (CC) mode
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 |
|---|---|---|---|---|
| Maximum settable current *1 | +840A | +126 A | +63A | +31.5 A |
| Setting accuracy *2 | ±(0.75 % of rating) | |||
| Resolution | 0.1A | 0.01A | 0.005A | 0.002 A |
| Line regulation *3 | ±1600mA | ±240 mA | ±120mA | ±60 mA |
| Load regulation *4 | ±1600mA | ±240 mA | ±120mA | ±60 mA |
| Rise time(TYP) *5 | 1 ms | |||
| Fall time(TYP) *6 | 1 ms | |||
| Response switching | FAST, SLOW | |||
| Slew rate switching *1 | 800A/ms or more *7 | 120A/ms or more *7 | 60A/ms or more *7 | 30A/ms or more *7 |
| 400A/ms | 60 A/ms | 30 A/ms | 15 A/ms | |
| 200A/ms | 30 A/ms | 15.0A/ms | 7.5 A/ms | |
| 20A/ms | 3 A/ms | 1.50A/ms | 0.75 A/ms | |
| 2A/ms | 0.30A/ms | 0.150A/ms | 0.075 A/ms | |
*1. During parallel operation, this will be the value multiplied by the number of units in the configuration.
*2. Applies to a range of 1 % to 100 % of the rated current.
*3. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load.
*4. This is the amount of change when the voltage is changed from the rated voltage and rated power to 1/10 of the rated voltage.
*5. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 10 % to 90 % of the rated current when the input current
value is changed from 0 % to 100 % of the rated current. When the slew rate is set to MAX.
*6. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 90 % to 10 % of the rated current when the input current
value is changed from 100 % to 0 % of the rated current. When the slew rate is set to MAX.
*7. MAX will appear on the display.
Constant resistance (CR) mode
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 |
|---|---|---|---|---|
| Conductance rating | 160S | 2400.0 mS | 600.000mS | 200.000 mS |
| Setting range | 0S to 168S | 0 mS to 2520.0 mS | 0mS to 630.000mS | 0 ms to 210.000 mS |
| Setting accuracy *1 | ±(0.5 % of setting + 0.5 % of rating) | |||
| Resolution | 20mS | 0.20 mS | 0.05mS | 0.02 mS |
| Response switching | FAST, SLOW | |||
*1 Converted value at the input current.
Constant Power (CP) mode
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 |
|---|---|---|---|---|
| Maximum settable power *1 | 21000W | |||
| Setting accuracy *2 | ±(0.5 % of power rating + 0.5 % of current rating × Vin) | |||
| Resolution | 2W | |||
*1 During parallel operation, this will be the value multiplied by the number of units in the configuration.
*2 Applies to a range of 5 % to 100 % of the rated power. Rating indicates the rated current value.
General Specifications
| Item | PXZ20K-50 | PXZ20K-500 | PXZ20K-1000 | PXZ20K-1500 | |
|---|---|---|---|---|---|
| Weight | Approx. 41 kg (90.39 lbs) | Approx. 38 kg (83.78 lbs) | Approx. 37 kg (81.57 lbs) | Approx. 37 kg (81.57 lbs) | |
| Dimensions | 430 (16.93)(MAX455 (17.91))W × 128 (5.04)(MAX160 (6.30))H × 720 (28.35)(MAX980 (38.58))D mm (inches) Refer to Outline Drawing |
||||
| Environmental conditions | Operating environment | Indoor use, overvoltage category II | |||
| Operating temperature | 0℃ to +40℃ | 0 °C to +50 °C (32 °F to +122 °F) | |||
| Operating humidity | 20% rh to 85% rh (no condensation) | ||||
| Storage temperature | -25 °C to +60 °C (-13 °F to +140 °F) | ||||
| Storage humidity | 90 % rh or less (no condensation) | ||||
| Altitude | Up to 2000 m | ||||
| Cooling method | Forced air cooling using fan | ||||
| Accessories | AC INPUT terminal cover, External control connector kit (1 set), Chassis connection wire, DC INPUT terminal cover, DC INPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pc.), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 sheet), Getting Started Guide (1 copy), Heavy object warning label (1 piece) | ||||
| Withstanding voltage | Between primary and FG | 2200 Vac for 1 minute | |||
| Between primary and secondary | |||||
| Between secondary and FG | 500 Vdc for 1 minute | 1800 Vdc for 1 minute | 3000 Vdc for 1 minute | ||
| Insulation resistance | Between primary and FG | 30 MΩ, 500 Vdc | |||
| Between primary and secondary | 30 MΩ, 500 Vdc | 30 MΩ, 1000 Vdc | |||
| Isolation voltage | ±250V | ±1000V | +2000V/-1000V | ||
| Electromagnetic compatibility (EMC) *1 *2 | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 61326-1 (Class A *3) |
||||
| Safety *1 | Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *4, Overvoltage category II, Pollution Degree 2 *5) |
||||
*1 Does not apply to specially ordered or modified products.
*2 Only for models with CE mark / UKCA mark on their body.
*3 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*5 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.