This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
The All-Rounder. Hipot, Insulation Resistance, Ground Bond, Leakage or Partial Dischage,this analyzer covers it all!
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
Electrical Safety Multi-Analyzer
Model:
TOS9300 series
Maker:
KIKUSUI
Product Features and Advantages
- All-in-one safety tester model(TOS9303LC)
- New amplifier type allows for 40A AC?DC ground bond testing(Ground bond tester models)
- Electrical breakdown inspection setting available
- AC 5 KV/100mA,DC 7.2 kV/100 W Hipot test
- Touch current/protective conductor current/leakage current testing(TOS9303LC)
- LAN/USB/RS232C standard digital interface
- Easy to read LCD display for real time monitoring during tests, All measurement values and standard outlines displayed in each test
Use
- Safety standard tests for electrical equipment / electronic components
- Medical device leakage current testing(patient current)
- Electrical safety standard testing for automotive components
- PV(solar battery)module withstanding voltage/insulation resistance testing
TOS9300 Safety Analyzer Product Overview
Line up
TOS9300 | Manual… Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V),Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9301 | Manual… Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV / 13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9301PD | Under development |
TOS9302 | Manual… Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Measurement range of ground bond testing: 0.001M Ω to 0.600G Ω (3.0A to 42.0A), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9303 | Manual… Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV/13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V),Measurement range of ground bond testing:0.001 Ω to 0.600 Ω(3.0A to 42.0A), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |
TOS9303LC | Manual… Max output-voltage of AC hipot testing: 5kV / 100mA(500VA), Max output-voltage of DC hipot testing: 5kV /20mA,7.2kV/13.9mA(100W), Measurement range of insulation resistance testing: 0.001M Ω to 100.0G Ω(DC-25V to -1000V / DC+50V to +7200V), Measurement range of ground bond testing: 0.001 Ω to 0.600 Ω(3.0A to 42.0A), Measurement range of leakage current testing: 1μA to 100mA(rms), Rise-time control / Fall-time control function provided, Output voltage and panel settings are controlled through LAN / USB / RS-232C. |